IBM Tivoli Network Manager IP 3.8.0 Fix Pack 7 was released on Sep 11, 2013. This Fix Pack supersedes all previous fix packs and we highly recommend that all customers running version 3.8 of ITNM begin planning to deploy this latest update or begin plans to upgrade to ITNM version 3.9, 4.1 or later. Contact us today to receive information about how we can help you upgrade your monitoring environment.
Download Description
Known issues with V3.8.0 Fix Pack 7
=============================================================================
Known problems are documented in the form of individual Technotes in the Support knowledge base.
Go to the following link to perform an advanced search of the knowledge base:
http://www-01.ibm.com/software/sysmgmt/products/support/IBMTivoliNetworkManagerIPEdition.html
Go to the following link to retrieve all technotes for version 3.8 of Network Manager:
http://www-01.ibm.com/support/search.wss?tc=SSSHRK&q=technote+3.8
Installing the V3.8.0 Fix Pack 7
=============================================================================
Full details on how to install this fix pack can be found in the INSTALL file, which can be downloaded below.
Summary of fixes in V3.8.0 Fix Pack 7
=============================================================================
List of all customer-reported issues that have been fixed in this fix pack,with a link to the fix description for each issue.
APAR: IV00342
-------------
Abstract: NCP_TRAPMUX FORWARDS TRAP PACKETS USING INCORRECT LENGTH
Description: When routing snmp traps through the ncp multiplexor, it appears that while
it will receive the trap ok it only will forward out 1024 bytes.If the trap is longer than
that, it just truncates the trap.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00342
APAR: IV00602
-------------
Abstract: ITNMV3.8 DNS LOOKUP TOOL ERROR
Description: When an attempt is made to use the tool DNS Lookup in TopoViz (ITNM client in
TIP/Web GUI) or launching the DNS Lookup tool from ITNM GUI,the tool fails with the error.
This occurs even if the Domain name is changed from the default domain name.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00602
APAR: IV00818
-------------
Abstract: POLLER EXITS UNEXPECTEDLY WHEN DB2 IS NOT AVAILABLE.
Description: Symptom: Poller exits and generates core file when DB2 is not available.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00818
APAR: IV01020
-------------
Abstract: ITNM38 TRUNK PORTS PLACED IN DUMMY GROUP.
Description: Trunk ports that are administratively down are placed in "dummy
cards" group and not in the correct fixed module group.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01020
APAR: IV01170
-------------
Abstract: ITNM_STATUS NCO COMMAND TRIES TO SHOW THE STATUS OF ALL MANAGED
PROCESSES IN THE PA INSTEAD OF ONLY network manger ONES.
Description: Currently when running the itnm_status nco script we are getting
all the processes under the PA in the Omnibus instead of only the network manger related
ones ( PA, objserver, mttrapd ). Additionally, the status of the other PA processes is not always correct, which
may lead to some confusion about the true status of those processes.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01170
APAR: IV01320
-------------
Abstract: MARKING DEVICES AS UNMANAGED WHEN THE BACKUP DOMAIN IS
ACTING PRIMARY FAILS TO SET NMOSMANAGEDSTATUS IN PROBE EVENTS
Description: Unmanage a device when in failover mode, with the backup domain
having become the acting primary domain, unmanage one of the
devices. Events from the network manger poller are correctly suppressed.
However, events from other sources, such Syslog or Mttrapd
(SNMP) probe fail to have the NmosManagedStatus field set
correctly to 1. This means they show up on Event Lists that
use NmosManagedStatus to filter out events from devices that
are known to be unmanaged.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01320
APAR: IV01535
-------------
Abstract: POLLER CONTINUES TO POLL AN UNMANAGED CHASSIS
Description: Customer can unmanage a chassis from the gui (hopview) and can
still see polling traffic going to that entity. It appears to only be snmp poll traffic because
the tcpdump shows ICMP echos stop when unmanaged.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01535
APAR: IV01549
-------------
Abstract: WHEN RIGHT CLICKING AND CHOSING TO "GRAPH SNMP MIB DATA" ERROR
RECEIVED "... HOST CANNOT BE FOUND IN THE NCIM DATABASE"
Description: 1) In hop view, I searched for the node in the domain. Select
this node.
2) When the view shows up, I right clicked and chose to "Graph
SNMP MIB Data". I go to the second tab, select any poll.
3) When I select "OK" to graph the data, I receive the message:
"The specified host cannot be found in the NCIM database. Please
choose another." This is caused when no interface record exists in scratchTopology with an m_IpAddress of the chassis.
Action:
The fix is to check for chassis objects that have no corresponding interface records in CreateScratchTopology and tag them.
A change to ModelNcimDb.cfg will create records in the ipEndPoint table for chassis that have been tagged.
If the NCHOME/etc/precision/ModelNcimDb.cfg has been customized before, then the existing file should be merged with
NCHOME/etc/precision/default/ModelNcimDb.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01549
APAR: IV01634
-------------
Abstract: JAVA.LANG.CLASSCASTEXCEPTION IN JAVA CONSOLE
Description: java.lang.ClassCastException in Java Console caused by fix for IZ96220.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01634
APAR: IV01669
-------------
Abstract: THE SAVED NETWORK VEIW LAYOUT CHANGED TO ORIGINAL AFTER DOMAIN
RESTART WHERE DISPLAY LABELS CONTAIN MUITI-BYTE CHARATERS
Description: The saved network view layout changed to original after domain
restart where devices' display labels contain muiti-byte characters.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01669
APAR: IV01706
-------------
Abstract: HOP VIEW URL IGNORES DOMAIN PARAMETER
Description: HopView URL are not working in multi domain.
HopView ignores the 'domain' parameter and so it does
not work in multidomain environments, where the 'domain' parameter is required.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01706
APAR: IV02082
-------------
Abstract: DBI_FACTORY.PM NEEDS TO BE ALTERED TO ENABLE LOCAL DB2 CATALOG
USE IN HADR ENVIRONMENT.
Description: Running any script that uses ncp_perl, for example RemoveNode.pl
returns the following: Connecting to database.
critical: Database Connection Error: [IBM][CLI Driver] SQL30081N
A communication error has been detected. Communication protocol
being used: "TCP/IP". Communication API being used: "SOCKETS".
Location where the error was detected: "1.1.1.1".Communication function detecting the error: "connect".
Protocol specific error code(s): "111", "*", "*".
SQLSTATE=08001 (where "1.1.1.1" represents the IP address for the socket).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02082
APAR: IV02127
-------------
Abstract: POLLER FAILED TO RECOGNISE SQLSTATE 40003 AS A DISCONNECT FROM
THE DATABASE.
Description: The poller fails to recognized the SQLState message number 40003
as a disconnect message. As a result it does not try to recover the connection.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02127
APAR: IV02229
-------------
Abstract: ARGUMENT TO NCP_CTRL -LOGDIR SWITCH NOT HONOURED CORRECTLY WHEN IT IS NOT THE DEFAULT DIRECTORY
Description: Normally, the -logdir switch for ncp_ctrl can be used to control
where all log and trace files are placed for the domain being
run.Only the first few lines of the trace files appear in the specified directory, while the remainder appear in the default location.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02229
APAR: IV02407
-------------
Abstract: MALFORMED ERROR IN UDP PACKET SENT WHEN TRACEROUTE AGENT IS ENABLED.
Description: Bad length value 2048 > IP payload length
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02407
APAR: IV02671
-------------
Abstract: NCP_POLLER PROCESS DEADLOCKS IN CERTAIN SITUATIONS WHEN FAILOVER IS CONFIGURED
Description: After starting up, the poller stops polling.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02671
APAR: IV02808
-------------
Abstract: WRENCH ICON CAN TAKE A LONG TIME TO APPEAR
Description: When there are a large number of entities in the view,
it can take some minutes for the wrench icon (or spanner icon)
to appear when you right click on a device a select "Unmanage".
The same is not true when there are a small number of entities in the view.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02808
APAR: IV02846
-------------
Abstract:THE 'PLUS' BUTTON IN TRIGGER CONDITION TAB DOES NOT WORK.
Description: When creating a new poll definition (generic or basic threshold).
The plus sign (to add another condition) in the trigger threshold tab does not work. It produces errors:
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02846
APAR: IV02995
-------------
Abstract: ITNM_ CONTROL SCRIPTS CAN FAIL WHEN PROCESS ID IS LESS THAN 5
DIGITS AND TWO PROCESSES MATCH THE PATTERN
Description: The pattern in script allows for multiple process IDs to be matched where one of the processes is less than 5 digits in length.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02995
APAR: IV03128
-------------
Abstract: ITNM3.9 LARGE NETWORK VIEW STALLS TIP
Description: When creating a large number of views the tip, java
process will use all available memory and stop working. The
views won't be displayed.Further editing isn't possible until
the views are deleted from the ncpoller db.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03128
APAR: IV03133
-------------
Abstract: CREATETRUNKCONNECTIONS STITCHER FIX.
Description: Customer is using network manger in a multiple virtual machines environment
connected on a switch port that is a trunking VLAN.
The stitcher is connecting each of the VLAN trunk end points
directly to the VMs. This meant that in cases where there were
many VMs connected to the same physical switch port a large
number of connections were being created ( numConnections =
numberofVLANs * numberOfVMs ).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03133
APAR: IV03148
-------------
Abstract: MULTI TABS PROBLEM ON ITNM3.8
Description: The below 2 issues always occur, while following the steps.
Issue-1:
1> Open "Discovery Configuration" , select DomainA and make some
change in the advanced. Do not save.
2> Open "Discovery Status", select DomainB. Do nothing.
3> Go back to "Discovery Configuration", still red words remind
you to save the change and the domain drop-down list is still
domainA.
4> Click the 'save' button. Saved, and the domain drop-down list
refreshed from DomainA to DomainB(sync with the drop-down list
of "Discovery Status"?), but the configurations in the webpage
are still of DomainA.
5> Click the 'save' button again, DomainB scope config over-writed by DomainA's
Issue-2:
1> Start the discovery for DomainA and DomainB
During the disco process, execute the following steps.
2> Open "Discovery Status" and select DomainA
3> Open "Discovery Config" and select DomainB
(select different Domain from step1).
=> verify the message "Downloading..."
4> Back to "Discovery Status", where the domain drop-down list
is still domainA, and Click "Stop" button.
=> then Discovery process for domainB stopped while we meant
to stop domainA's.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03148
APAR: IV03378
-------------
Abstract: FILTER WAS NOT ENCLOSED IN BRACKETS WHICH LEAD TO INADEQUATE
RESULTS WHEN THE FILTER CLAUSE HAS MORE THAN ONE STATEMENT.
Description: 2 domains that contains identical devices. When we try to create
a specific view, for a specific domain, all devices which are in
the ncim DB are included even if there are not in the same domain. Devices have 2 separate entityID.
Filter was not enclosed in brackets which lead to inadequate results when the filter clause has more than one statement.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03378
APAR: IV03670
-------------
Abstract: INSTALLER NEEDS TO CHECK THAT THE USER INSTALLING ITNM HAD
ACCESS TO THE DIRECTORY ABOVE NETCOOL
Description: The user is installing network manger into a directory called netcool and doesn't have access to the directory above.
You are installing network manger as a not root user to the path: /ITNM_3.9/NoAccess/Netcool.The installed has a built in logic to not create a directory
called netcool under an existing Netcool directory. The installer will try and
create the TIPV2 in on the same level as the Netcool directory which the user installing network manger doesn't have access to.
This will cause the installer to fail and report a "Catastrophic failure encountered when creating installation plan."
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03670
APAR: IV03865
-------------
Abstract: MIB BROWSER SNMP GET HANDLING INCORRECT FOR SCALAR VALUES
Description: 1.start SNMP MIB browser 2.select sysName of system mib Group from the tree 3. add index '0' to OID box
and then run SNMP GET request (such as 1.3.6.1.2.1.1.5.0 <= 0 was
added) 4. got result (without fail) and Name shows like 1.3.6.1.2.1.1.5.0.0
<= another 0 was added. 5. then for next request, he omit the index '0' such as
1.3.6.1.2.1.1.5 <= no '0' was added 6. got result (without fail) and Name shows sysName.0. He thinks that the result 4. and 6. are both wrong.
He assume with 4. Name shows 1.3.6.1.2.1.1.5.0. He assume with 6. the request gets failed..(SNMP GET-NEXT results same as his assumptions).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03865
APAR: IV03968
-------------
Abstract: BACKUP POLLER WILL ATTEMPT TO TRUNCATE NCPOLLDATA.POLLDATA WHEN NOT ACTING PRIMARY.
Description: In a failover environment, the backup poller will attempt to
truncate the stored data in ncpolldata.polldata at the same time
as the Primary poller is taking the same action. This can cause a deadlock on the database.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03968
APAR: IV04053
-------------
Abstract: NODE NAMES LONGER THAN 45 CHARACTERS GET TRUNCATED IN STRUCTURE BROWSER
Description: Node names which are longer than 45 characters get truncated and
at the end three dots (...) get appended. Customers would like
to be able to see the full name of the node.
If the TIPHOME/profiles/TIPProfile/etc/tnm/structurebrowser.properties file has been customized before,
then the existing file should be merged with TIPHOME/profiles/TIPProfile/etc/tnm/default/structurebrowser.properties with the appropriate value set.
Implemented a new configurable field structurebrowser.tree.node.name.maxLength=0 in structurebrowser.properties file.
To activate the function, add the following lines to the TIPHOME/profiles/TIPProfile/etc/tnm/default/structurebrowser.properties file.
# Length at which the navigation tree should truncate the node name
# Default is 0, meaning that no truncation will take place.
# structurebrowser.tree.node.name.maxLength=0
http://www-01.ibm.com/support/docview.wss?uid=swg1IV04053
APAR: IV05797
-------------
Abstract: WHEN USING NCIM REPLICATION MODE, THE BACKUP NCP_MODEL FAILS TO
SUCCESSFULLY MIGRATE DATA TO NCIM
Description: When network manger is configured to use NCIM Failover mode, Backup ncp_model does not migrate data to NCIM correctly.
As a result, ncim.connects & ncim.topology links content in the
backup NCIM is not same as Primary NCIM. Though, the actual
number of entities i.e. ncim.entity matches between both.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV05797
APAR: IV06272
-------------
Abstract: NETWORK VIEWS ARE SLOW OR HANG DURING DISCOVERY.
Description: When a discovery is being performed or we fake a discovery by
updating the ncim.domainMgr table, the Network Views are very
slow to respond for a while afterwards. This is due to the
Network View caches being refreshed and locking the domainMgr table each time.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06272
APAR: IV06477
-------------
Abstract: XML RESPONSE FROM SAM COLLECTOR CAUSES COLLECTOR TO EXIT
Description: XML response from the SAM
may not always include characters that the XML parser
we use can parse. This causes the Collector to exit.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06477
APAR: IV06779
-------------
Abstract: TRACEROUTE AGENT CAUSES UDP PACKET FROM PORT 0 CAUSING FIREWALL
ERROR
Description: When the traceroute agent is enabled, UDP packets are sent at
the behest of the agent that come from TCP Source Port 0. This
can cause firewall issues as many firewalls check for packets
originating from port 0, and blocking such packets.
Implemented a new configurable field m_UdpSrcPort in DiscoPingHelperSchema.cfg.
It will be used as the SrcPort for the TraceRoute udp packet sent.Implemented a new
configurable field m_UdpSrcPort in DiscoPingHelperSchema.cfg. It will be used as the
SrcPort for the TraceRoute udp packet sent.
If the NCHOME/etc/precision/DiscoPingHelperSchema.cfg file has been customized before, then the existing file should be merged with
NCHOME/etc/precision/default/DiscoPingHelperSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06779
APAR: IV06841
-------------
Abstract: DLA ARE NOT PROPERLY RECONCILLED WITHIN TADDM, SUCH AS WHEN
THE SIGNATURE ATTRIBUTE DIFFERS FOR THE SAME DEVICE
Description: In some instances the devices exported by the
DLA are not properly reconciled within TADDM, such as when
the Signature attribute differs for the same device.
By using the ncp.dla.signatureOverride property you can
manually configure the Signature used by the DLA on a per-
device basis, thus bypassing automated Signature generation.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06841
APAR: IV07103
-------------
Abstract: KNP AGENT NOT PASSING HISTORICAL DATA TO TDW
Description: The customer has an agent instance configured to migrate 100000
rows but the database has less than 100000 rows when this was
configured. The agent tries to migrate the data for the timestamp when the
configuration changed and it will just update the timestamp when
there are 100000 rows. In this scenario this will never
happen and the agent will get stuck on a query that never
returns data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07103
APAR: IV07624
-------------
Abstract: ITNM3.8 SYMPTOM ALERTS THAT CLEAR THEN ALERT AGAIN GET
INCORRECTLY MARKED AS ROOT CAUSE
Description: Two alerts are correctly raised as root cause and symptom. If the
symptom alert clears and then alerts again it gets incorrectly
marked as root cause.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07624
APAR: IV07631
-------------
Abstract: SNMP STACK NEEDS REPORTABLEFLAG TO BE SET TO 1 IN SOME CASES
Description: The reportable Flag needs to be set to 1 in case of possible
packet that can not be decoded by target device.
For latest Huaway firmware the devices expects the flag to be
set to 1, but it is not during the SNMP GetNext statements
issued by network manger. We need a change to the network manger
SNMP stack such that it checks the PDU type that its is about to send and sets the reportableFlag accordingly.
This means that we'd be able to successfully discover the Huawei devices with this new firmware.
In theory this could impact discovery of other vendors equipment
via SNMPv3 but if they are following the standard then they
should be ignoring the reportable Flag so this is a relatively
low risk.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07631
APAR: IV07647
-------------
Abstract: NETSCREENINTERFACE AGENT CRASHED DUE TO MEMORY LEAK
Description:NetScreenInterface agent crashed due to memory leak and
mismatched number of ifDescr/ifSpeed in some of the NetScreen devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07647
APAR: IV07753
-------------
Abstract: NETWORK MANAGER IP EDITION 2011 INTEGRATIONS R3 (3.9)
Description: Support added for the following discovery Agents:
(1) Juniper Box Anatomy Discovery Agent for Juniper Physical
Inventory discovery
(2) HSRP Secondary Virtual IP Discovery Agent for HSRP enabled
devices
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07753
APAR: IV07908
-------------
Abstract: MPLS VPN DETAILS REPORT FAILS TO LOAD
Description:The MPLS VPN Details Report (itnm_mpls_vpn_details.rptdesign)
fails to generate with the browser status shows as loading. The
NCIM temporary table space's datafile in Oracle was highly
increased from 100 MB to 33 GB while running the report. The
SQL query needs some improvement in order to display the report
correctly.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07908
APAR: IV07909
-------------
Abstract: NETSCREENIPROUTINGTABLE AGENT CRASHED DUE TO MEMORY LEAK
Description: NetScreenIproutingTable agent crashed due to memory leak and
mismatched number of ifDescr/ifSpeed in some of the NetScreen devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07909
APAR: IV08027
-------------
Abstract: DEVICE SYSLOGS FILLED WITH AUTHENTICATION FAILURE MESSAGES
WHEN DISCOVERY RUN.
Description: Device syslogs are filled with Authentication Failure messages
when discovery is run,so the logs fill up quickly. Customer have 55
SNMP community strings configured in the domain.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08027
APAR: IV08192
-------------
Abstract: UNABLE TO CREATE A NETWORK VIEW USING A THE LINGERTIME FIELD
Description:The GUI Network View creator allows the user to select Filter on
a Chassis and the field lingerTime,
1. Create a Network View using Filter, on Chassis and field lingerTime some value
2. The view has 0 nodes, which is wrong when compared to what is
in model.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08192
APAR: IV08223
-------------
Abstract: REQUEST TO BACKPORT CHANGE FOR 3.9 FULLDISCOVERY.STCH TO 3.8 FUL
LDISCOVERY.STCH RELATED TO "ISPINGFINDERRUNNING"
Description:Full Discovery.stch to be backported to 3.8 FullDiscovery.stch in
regard to checking "isPingFinderRunning" as this would eliminate warnings.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08223
APAR: IV08858
-------------
Abstract: POLL DEFINITION SYNTAX ERROR WHILE NAME STARTS WITH NUMERIC
Description:Poller sometimes cannot work while poll definition name starts
with numeric or special character.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08858
APAR: IV09223
-------------
Abstract: BUG IN REMOVEINFERREDCEDUPLICATES RESULTING IN MISSING DEVICES
WHEN CES ARE INFERRED
Description:When inferring CE devices, due to overlapping IP addresses, the
RemoveInferredCEDuplicates stitcher deleted valid entities in
order to replace them with inferred CE entities. The stitcher
needs some minor modifications so it doesn't do this.
The query assumes it is looking for "no access" main nodes but
doesn't specify that it is a main node and s o
can get a VLAN object or similar no access entity on a device
which does have SNMP access.
This causes the stitcher to later delete the device. The initial
query should also check the entity type.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09223
APAR: IV09257
-------------
Abstract: NO TOOLTIP VALUES SHOW WHEN AT LEAST ONE VALUE IS MISSING IN
NETWORK VIEW
Description:If the tooltips for a particular view contain a value (e.g.
"{custom.myValue}") that is not available for all entities, then
the tooltips for all those value will not be replaced. Instead,
the tooltip will still display the placeholder string, e.g {custom.myValue}.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09257
APAR: IV09258
-------------
Abstract: REQUIREMENT FOR HEARTBEAT KEEPALIVE BETWEEN NCP_CONFIG AND
DISCOVERY STATUS GUI
Description:The backend process ncp_config has been modified to send
keepalive heartbeat messages every 300 seconds.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09258
APAR: IV09454
-------------
Abstract: SNMP MIB BROWSER DOES NOT RESOLVE HOST NAME AGAINST NCIM DB
Description:When using the SNMP MIB Browser, and typing in a hostname in the
"Host" box, the name resolution is done by the Operating System,
not by network manger.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09454
APAR: IV09740
-------------
Abstract: PERFORMANCE ISSUES WITH NETWORK VIEWS ACROSS A WIDE AREA
NETWORK
Description:network manger Network Views and Network View tree menu takes a long time to be
displayed when the when using a remote DB server i.e. being accessed across a wide area network from a local TIP/ITNM UI server.
APAR: IV10023
-------------
Abstract: THE VIEW NCPOLLDATA.POLLITEMVIEW DO NOT RETURN IP ADDRESS
Description:The view ncpolldata.pollItemView do not return ip address for
chassis and break reports because the a line from "createPollDataDb.sql" definition is not correct.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10023
APAR: IV10059
-------------
Abstract: STRUCTUREBROWSER HAS CHANGED TO TABLE MODE AFTER APPLYING ITNM
FP6.
Description: The structure browser in TIP has changed to table mode after
applying ITNM FP6.
It is stated in the release notes as follows: 5.4.3.
If you want the Structure Browser portlet to open in tree mode by default,set the property to 'tree' instead.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10059
APAR: IV10434
-------------
Abstract: MIS-TRANSLATION IN JAPANESE VERSION OF THE DISCOVERY WIZARD WITH
REGARDS TO END NODE DISCOVERY
Description: On the End Node discovery Wizard page that asks about
End Node discovery, the Japanese translation suggests that the
end node filter will not be applied.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10434
APAR: IV10815
-------------
Abstract: NCP_NCOGATE CORE AT CNCOCONNECTION::READERMAINLOOP: LOOP HAS
BEEN TERMINATED
Description: The ncp_ncogate process is coring.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10815
APAR: IV11080
-------------
Abstract: LINGERTIME IS NOT CONSISTENT BETWEEN MODEL AND NCIM
Description: LingerTime is not consistent between Model and NCIM.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11080
APAR: IV11178
-------------
Abstract: EVENT GATEWAY FAILS TO CLOSE CONNECTION ON BACKUP OBJECTSERVER
WHEN FAILING BACK.
Description: The Event Gateway opens two connections to an ObjectServer.
When the gateway is connected to the Backup ObjectServer and the
Primary becomes available again, the gateway fails back to the
Primary ObjectServer.
APAR: IV11270
-------------
Abstract: CDP AGENT RUNS INTO INFINITE LOOP - CAUSING OUT OF MEMORY
CONDITION
Description: Customer discovers a device that is causing the CDP agent to go
into a loop until it runs out of memory.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11270
APAR: IV11271
-------------
Abstract: 4 CISCO 3750 STACKED SWITCHES NOT BEING DISPLAYED AS 1.
Description: 4 Cisco 3750 stacked switches with 208 ports (54x4) should
appear as a single entity.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11271
APAR: IV11724
-------------
Abstract: NETWORK VIEW WITH IP FILTER RETURNS ZERO NODES
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11724
APAR: IV12417
-------------
Abstract: ITNM 3.9 CREATE IP FILTER VIEW DOCUMENTATION
Description: When performing the steps in the documentation ->
http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/index.jsp
?topic=%2Fcom.ibm.networkmanagerip.doc_3.9%2Fitnm%2Fip%2Fwip%2Fadmin%2Fr
eference%2Fnmip_adm_ipfiltersyntax.html. The result is always 0 devices in the network view.
Using OQL it is confirmed that the result in our replication should be n number of devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12417
APAR: IV12650
-------------
Abstract: CISCODEVICETELNET AGENT FAILS TO GET THE TOPOLOGY INFORMATION
FROM CISCO 2800 SERIES BY 'SHOW MAC-ADDRESS-TABLE'
Description: Cisco 2800 series routers FDB data can only find by telnet agent .
The supported 'show mac-address table' outputs: # show mac-address-table
Dynamic Address Count: 20 Secure Address.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12650
APAR: IV12759
-------------
Abstract: Disco Config and Status pages share the same domain session vari
able.
Description: Changing the domain in one of the pages, affects the other.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12759
APAR: IV12850
-------------
Abstract: ITNM KNP AGENT FRENCH MESSAGE TRANSLATION ERROR
Description: Status in the availability view in FRENCH in error.
In the monitoring view, the status is bad:it indicates EN
FONCTION while the status is Down, and HORS FONCTION while the status is UP.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12850
APAR: IV12927
-------------
Abstract: REDUCING VERBOSITY OF NCP_POLLER.SNMPPOLLER.<DOMAIN>.TRACE
CONTAINS LOT OF REPEATATIVE MESSAGES CAUSES LOGFILE TO GROW HUGE
Description: Customer need to reduce the volume of logging in
ncp_poller. SnmpPoller.<domain>.trace file as it causes the file to grow huge.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12927
APAR: IV13225
-------------
Abstract: DISCOVERYUPDATEMODE IS 0 AND LINGERTIME DESCREASED DURING
PARTIAL REDISCOVERY
Description: In SendTopologyToModel.stch, disco sends the request of update
to model.config for DiscoveryUpdateMode first, and sends the
request of Topology data update request to model at the end of stitcher.
However in the model side, it randomly got the message of
Topology Data update earlier than the message of
DiscoveryUpdateMode update in model.config. It turned out to use
the un-updated DiscoveryUpdateMode 0 and decided the Lingertime
to be checked.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13225
APAR: IV13278
-------------
Abstract: IN ITNM 3.8 NETWORK HEALTH VIEW, WHENEVER THERE IS A CLEAR SEVER
ITY FOR ANY DISCOVERED DEVICE, IT SHOWS WITH THE COLOR GREEN.
Description: In ITNM 3.8 Network Health View, whenever there is a clear
severity for any discovered device, it shows with the color
green, whereas in the Left Hand Side panel of Network view (Tree
View) => Max column, we don't see any green color icon (Actually
it shows no icon).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13278
APAR: IV13415
-------------
Abstract: NETSCREENINTERFACE AGENT CORE NOT HANDLING CONDITION PROPERLY
Description: The NetScreenInterface agent was not handling condition properly.
The device in question was returning empty nsVpnMonTunnelState list and the agent assume that the device will always return something.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13415
APAR: IV13837
-------------
Abstract: NCMONITOR TABLES IS NEVER PURGE
Description: NCMONITOR tables got never purged.Snmptarget contains all
targets since the first discovery.Need to run:
"delete from ncpolldata.monitoredInstance where entityId not in
((select entityId from ncim.entity));"
"delete from ncpolldata.monitoredInstance where entityId not in
((select entityId from ncim.interface));"
in adition to
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13837
APAR: IV14221
-------------
Abstract: THE DOMAIN_DROP.PL SCRIPT IS SUPPOSED TO INCREMENTALLY DELETE
ENTITIES FROM A DOMAIN.
Description: When deleting directly from the domainMgr table or deleting all
entities in a single command, the level of cascaded deletions
that are performed can result in a transaction that is too large
for the database to handle or is simply too slow. The
domain_drop.pl script resolves this by incrementally deleting
batches of entities from the domain before deleting the domain
itself, but this mechanism does not currently work. The entities
are deleted only at the end of the script, when the domain
itself is removed from the domainMgr table.This defeats the
purpose of the script, and can fail on very large topologies.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV14221
APAR: IV14476
-------------
Abstract: MPLS VPN VIEWS DISPLAY INCORRECTLY IN ITNM 3.8 FP6
Description: The MPLS VPN displays too many devices,there by removing
them from MPLS core cloud and hence creating an empty MPLS core cloud.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV14476
APAR: IV15667
-------------
Abstract: FIND IN NETWORK VIEWS STOPS WORKING
Description: Right Hand Tool for Events in AEL "Find in Network
Views" stops working after a while.
The test fix introduced code that encounters a defect in the DB2 JDBC driver.
This APAR is raised to record the changes required to mitigate
for that defect in the DB2 JDBC driver.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV15667
APAR: IV15884
-------------
Abstract: ITNM POLLER NOT CLEARING EVENTS RAISED BY A PREVIOUS INSTANCE.
Description: ITNM poller not clearing events raised by a previous instance.
Existing active events need to be read on poller start up.
ActiveEvent table has been updated in NcPollerSchema.cfg file.
If the NCHOME/etc/precision/NcPollerSchema.cfg file has been customized before,
then the existing file should be merged with NCHOME/etc/precision/default/NcPollerSchema.cfg with the appropriate value set.
APAR: IV16149
-------------
Abstract: wrong subnet and netmask for Chassis IpAddress
Description: The current issue is that the device has wrong information.
It seems that when the discovery runs the first time, the
default network is /24 for all the devices and after this netmask is
never updated according to the SNMP information recovered when ITNM
build the devices and its interfaces. First the default value of /24 is
misleading. The default should be /32 (= scope of a single
host) and secondly this netmask (/32) should be updated according to the SNMP info.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV16149
APAR: IV16616
-------------
Abstract: DATA IMPORT OF VIEWS IS FAILING BECAUSE OF INVALID
ENTITYNAME(S) IN THE NCIM.ENTITYNAMECACHE TABLE.
Description: Data import of views is failing because of invalid
entityName(s) in the ncim.entityNameCache table. Export from
old system worked OK. Also the import of the views fails if the
itnmExportedEntityNameCache.dat file is empty.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV16616
APAR: IV16617
-------------
Abstract: network manger 3.8 FP5 NCP_CTRL
Description: The ncp_ctrl process has a master slave mode which allows it to
run processes on remote servers. The function is independent of the
remote pollers and can start any network manger process and I don't there fore see it as part of the question around support for remote pollers.
When testing on site we saw that while the slave ncp_ctrl process did indeed start the remote
process, however it failed to stop it again when the master ncp_ctrl was stopped.
APAR: IV16886
-------------
Abstract: MAINTENANCESTARTTIME AND MAINTENANCEENDTIME IS NULL IN MANAGED STATUS TABLE. (APAR=IV16886)
Description: When we keeping any device in maintenance mode then no data is
saved in the managedstatus table like MaintenanceStartTime and MaintenanceEndTime, its always NULL but the changetime column is being filled with correct date-time.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV16886
APAR: IV18264
-------------
Abstract: WHEN MULTIPLE POLLERS ARE RUNNING, ALL POLLERS TRY TO PRUNE DATA
RESULTING IN DEADLOCKS
Description: We have noticed that when using multiple pollers all poller
instances try to launch the pruning process resulting in deadlocks on the pollData table and resulting in warning messages in the poller log.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV18264
APAR: IV18992
-------------
Abstract: Changing the locale settings from en_US.UTF-8 to RU_RU.UTF.8
then save GUI and start Discovery generate error in disco log.
Description: On network manger AIX install when
customer is changing the locale settings from en_US.UTF-8 to
RU_RU.UTF-8 then saves the discovery settings from GUI and start
FullDiscovery, ncp_disco.log reports :
2012-02-10T16:17:21: Warning: W-RIV-002-140: [1t]xxxx.cc(1563)The database insert was invalid.
Column and values lists different lengths, can not construct record from
insert. Column list length: 35 value list length: 36.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV18992
APAR: IV19168
-------------
Abstract: LINGERTIME VALUE DISPLAY ACCIDENTALLY REMOVED FROM DEVICE STRUCT
URE VIEW AFTER APPLY FP1 (APAR IN ERROR IS IV08192)
Description: This APAR is created as AE/MDV APAR with "MDVREGR" class.
LingerTime value was left off Device Structure Display in 3.9 FP1
http://www-01.ibm.com/support/docview.wss?uid=swg1IV19168
APAR: IV19726
-------------
Abstract: ITM AGENT IS SLOW TRANSFERRING DATA FROM NCPOLLDATA TO TDW
Description: ITM agent is very slow in moving data from local db(NCPOLLDATA)
to Tivoli Data Warehouse(TDW) due to inefficient queries under getPolldata.pl
http://www-01.ibm.com/support/docview.wss?uid=swg1IV19726
APAR: IV19728
-------------
Abstract: POLLER STORING TOO MANY ROWS IN NCPOLLDATA FOR PINGS
Description: Poller stores two rows for a given polled instance (e.g. ICMP).
This request is to reduce number of rows to be one(1) - so that
we store both polled time and response time under single row.
The change will decrease number of rows we store in NCPOLLDATA
and at the same time reduces overhead on Poller.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV19728
APAR: IV20184
-------------
Abstract: SNMP HELPER(NCP_DH_SNMP) DOES NOT PROCESS OTHER GENERIC
COMMUNITY STRINGS WHEN PREVIOUSLY SUCCEEDED ONE FAILS
Description: Snmp helper fails to try other community strings when previously
succeeded string fails - resulting the device in 'NOSNMPAcecess'
and/or duplicate nodes if EntityName doesn't match.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV20184
APAR: IV20360
-------------
Abstract: $PRECISIION_HOME/PRODUCTS/TNM/BIN/ITNM_POLLDATA_PRUNINGSCRIPT T
AKES 3 DAYS TO PRUNE POLLDATA WHEN IT IS LARGE.
Description: PrunePollData uses JOINs which cause Informix to delete entries very slowly from
poll Data. To simplify the deletes,we need to make a schema change.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV20360
APAR: IV20889
-------------
Abstract: SOME MPLS TE PATHS ARE NOT VISUALISED CORRECTLY
Description: Some MPLS paths fail to be created where MPLS TE Tunnel Hop
devices are a mixture of Layer 2 and Layer 3 devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV20889
APAR: IV21588
-------------
Abstract: ALLOW SYNCHRONISATION OF BATCH TIMES BETWEEN MULTIPLE POLLERS TO CONTROL BANDWIDTH
Description: This chance is part of the STIME crit sit and tracked under the
following:Add new parameter for the VSAT poller to explicitly select the
TIME of the first poll. The requirement is that when operating multiple pollers so monitor a
satellite link it must by possible to synchronize the
batch times of those pollers. So that the bandwidth can be
controlled and thus prevent costs being incurred by exceeding
the bandwidth limits on the link.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV21588
APAR: IV22262
-------------
Abstract: NETVIEW DATA EXTRACTION DOES NOT WORK
Description: When the customer runs the exportNVData.sh script according to
instructions, it fails due to missing the Itnm_Unzip.class file.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22262
APAR: IV22788
-------------
Abstract: UNMANAGE/MANAGE ACTION CAUSES BACKUP POLLER TO POLL DEVICE.
Description: In a failover environment with a Primary and Backup running,
with the Primary domain healthy and acting primary, if the user unmanages,
then manages a device, the backup poller will begin polling that device, and
raising duplicate events.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22788
APAR: IV22933
-------------
Abstract: DISCO IP MALFORM
Description: When disco encounter Ip addresses malformed (If the IP Address
is not valid (e.g. 5 octets) or empty) it crash.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22933
APAR: IV22998
-------------
Abstract: NCP_CTRL FAILS TO PROCESS SIGCHLDS PROPERLY RESULTING IN KILLING
WRONG PROCESSES
Description: The problem was observed on AIX only
When ncp_ctrl receives SIGCHLD, it fails to process properly
and tries to stop wrong process.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22998
APAR: IV23046
-------------
Abstract: STITCHER LANGUAGE OPERATOR ISSUE
Description: ExecuteSQL on a column containing hyphen/minus returns NULL.
The commands SQLData / PrepareSQL / ExecuteSQL return NULL if
the column contains - (hyphen) as value.
APAR: IV23863
-------------
Abstract: COLLECTOR ENDED SUDDENLY AT THE END OF ITS WORK DURING
DISCOVERY.
Description: Collector ended suddenly at the end of its work during
discovery. No additional information available at this time.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV23863
APAR: IV24388
-------------
Abstract: COREBUILDER 3COM SWITCH AGENT FAILED DURING DISCOVERY DUE
TO FATAL ERROR.
Description: The agent is terminated due to the following error:
Error: An unrecoverable error occurred. Please contact IBM
Support.
Fatal Error: Duplicate Object Upon Insertion found in xxxxxx.cc at line 1902
Application terminating due to error.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24388
APAR: IV24427
-------------
Abstract: EVENT SYNCHRONIZATION BETWEEN THE EVENTS SHOW IN OMNIBUS AND THE
POLLER
Description: Restart of the ncp_poller process the new instance of the
poller will not clear any outstanding events which had been raised by the
previous instance.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24427
APAR: IV24695
-------------
Abstract: AE IV00446 FIX COMPLETION->OS AGENT FAILS ON 3.8 FP5 AND DISCO
FAILS
Description:
In adition to APAR IV00446 which partially solves the isuse:
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00446
disco still dies
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24695
APAR: IV24795
-------------
Abstract: UPDATE JAVA CERTIFICATE IN
/EXPORT/SRC/NCP/NCP_GUI/TOPOVIZ/APPLETSIGNING
Description: update Java certificate in
/export/src/ncp/ncp_GUI/Topoviz/appletsigning.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24795
APAR: IV24844
-------------
Abstract: ncp_perl core dump
Description: Symptoms:
ncp_perl is core dumping in a similar manner to IV00076.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24844
APAR: IV24939
-------------
Abstract: NEXUSCONTAINERS STITCHER DOESN'T WORK PROPERLY WHEN
DEALS WITH MULTIPLE CISCO NEXUS DEVICES
Description: When multiple Cisco Nexus devices are present into domain scope,
the NexusContainers stitcher add the correct containment only
for the first discovered device
As 'm_Name' column from working Entities table is unique, further
containment inserts will fail.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24939
APAR: IV24945
-------------
Abstract: PROCESSES CORE DUMP WHEN TRACE FILE ROTATION IS ENABLED AND THE
FILE REACHES 2GB
Description: When trace file rotate for the process, it core dump.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24945
APAR: IV25131
-------------
Abstract: RCA FAILS TO SUPPRESS EVENTS FROM THE CHASSIS IP WHEN THE GRAPH
ENDS ON AN INTERFACE WITH THE SAME IP.
Description:
Isolated-Suppression fails to suppress events from the chassis
when the graph though the network terminates on an interface with the same
IP.In the user case, the interface that is used to identify the
chassis is contained within an VLAN. Although the VLAN is
subsequently contained within the chassis, it is also isolated
within the chassis because the chassis device is not an
IP-FORWARDING device. So although connectivity extends from the
interface to the VLAN, the path is not continuous up to the
chassis entity.
Therefore when RCA encounters events from the Chassis entity, it fails to
complete a continuous path from the polling station all
the way to the chassis and does not mark the event as a symptom.
Action:
1.Modify the Discovery stitcher code so that the interface
is upwardly connected to the VLAN.
2. Modify the RCA code so that when the Isolated-Suppression
algorithm encounters an interface on the path that has the same
IP address as the chassis, it looks for events on the chassis
too and suppresses any events it finds on the chassis.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV25131
APAR: IV25842
-------------
Abstract: STACKED DEVICES NOT PROPERLY CONNECTED CAUSING PROBLEMS FOR
POLLER
Description: After installing fix for IV11271, customer found that the
connectivity between the stacked hubs was incorrect, all
devices were showing EntityType=1 and the same m_UniqueAddress.
So we were not properly polling all stacked entities
http://www-01.ibm.com/support/docview.wss?uid=swg1IV25842
APAR: IV26368
-------------
Abstract: RESOLVE LINGERTIME ISSUE WITH PERMANENTLY UNMANAGED DEVICES
Description: If devices are set to the Permanently Unmanaged state (status=2
or 3) in a discovery stitcher then Model never decrements the
LingerTime so that those devices never linger out.
APAR: IV26410
-------------
Abstract:DATABASE LOCKING IN ITNM POLLER
Description:Under specific conditions a lock can be held on DB2 tables that
prevents other applications acheiving a similar lock.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26410
APAR: IV26715
-------------
Abstract: FALSE PING FAIL EVENTS GENERATED WHEN NTP CLOCK ADJUSTMENTS ARE MADE.
Description: Very fast responses can appear to the poller to
arrive before the request is sent, resulting in ping fail events
where no such outage exists.
When network manger is processing very fast ping responses (in the order
of millisecs) occasionally an anomaly occurs with the
timestamps used for send/receive packets. The effect of this
currently is that the rtt appears negative and a timeout is
incorrectly triggered.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26715
APAR: IV26842
-------------
Abstract: WRONG FORMAT OF TIME IN EXCEL REPORT.
Description: When a report is exported as Excel file, then format of date in
the exported file is "yyyy-m-d hh:ss:mm", though it should be "yyyy-m-d
hh:mm:ss". *ss* and *mm* should be reversed.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26842
APAR: IV27657
-------------
Abstract: SQL QUERIES FROM THE STITCHER LANGUAGE FAIL FOLLOWING A DATABASE RECONNECTION.
Description:The customised stitcher, ReplaceDisplayLabel, directly accesses
an external database to retrieve the info used for the displaylabel. That
data is formatted and added to the scratchTopology data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV27657
APAR: IV27953
-------------
Abstract: NCP_MIB DOES NOT PROPERLY PARSE MODULE DEFINITION WITH MORE THAN
2 ITEMS
Description: The ncp_mib does not load the mib module definition with more
than 2 items
For an example in PF-GS_MIB-v4_0.mib there is a line with 2 items
identifier ::= { enterprises anritsu(1151) 2 1 7 }
which is not correctly parsed by ncp_mib.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV27953
APAR: IV28101
-------------
Abstract: NOSUCHNAME EVENTS GENERATED FOR ENTITIES THAT WERE POLLING WITHOUT ERROR.
Description: Configure SNMP Link State poll policy *with* interface
coping.(Policies without interface scopes will not trigger this
APAR).Failover to the Backup domain by stopping the entire Primary domain.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV28101
APAR: IV30474
-------------
Abstract: CDPLAYER STITCHER FAILS IF REMOTEIFNAME IS NULL
Description: The CDPlayer stitcher fails on the remote device that has an
interface to a null interface name.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30474
APAR: IV30624
-------------
Abstract: ITNM'S MODEL PROCESS SHOULD HONOUR LINGERTIME VALUES SET BY THE ITNM DISCO PROCESS.
Description: Model ignores LingerTime values set by Disco.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30624
APAR: IV30706
-------------
Abstract: TRANSLATION OF TIME PERIOD READS "PAST 1 YEAR" BUT CORRECT
TRANSLATION SHOULD BE "YEAR TO DATE"
Description: The default network manger reports contain a translation error
for one of the values presented via the report period drop down. In the
report period drop down, the Japanese text translates as "past 1 year" but
the time period in the report is from the beginning of the current year.
The expectation is that the report shows data from January 1st
of the current year. So the report is correct according to the expectated
result.
What is wrong is the value in the drop down list for the period.
Instead of reading "past 1 year" it should read "year
to date". The meaning is different. Past 1 year implies
a full year worth of data going back in time from today's date.
Year to date implies all data from the beginning of the current year.
NOTE: The results of the default report is correct. It is the
translation for year to date in the list of options in the drop
down that needs correcting.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30706
APAR: IV30911
-------------
Abstract: BY DEFAULT LOG FILES CAN GROW UNLIMITED IN SIZE. IN ADDITION
THE DOCUMENTATION SAYS THE DEFAULT LIMIT IS 102400 BYTES.
Description: By default, there is no limit to the size logs can grow
to. In addition the documentation needs to be updated to say
the default limit is 1GB and add a note on estimating log space
for planning.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30911
APAR: IV31296
-------------
Abstract: ASSOCADDRESS AGENT TO USE IPADENTADDR VALUE INSTEAD OF THE INDEX FOR THE IPADDRTABLE ENTRY.
Description: AssocAddress Agent Symptom: The AssocAddress agent use the index of the entry in ipAddrTable and according to RFC1213,
the index of ipAddrTable should be ipAdEntAddr.However, in some Alteon ADC and VADC
devices, the index of ipAddrTable is having a different value than ipAdEntAddr, i.e. ipAdEntAddr
with index IP.IP.IP.112 is having IP.IP6.IP.114 as it's value: ipAdEntAddr.IP.IP.IP.112: IP.IP.IP.114
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31296
APAR: IV31587
-------------
Abstract: SNMP TIMEOUT
Description: For every first SNMP query to determinate if the device responds
to SNMP, the timeout configfured is not used.
E.g:
Timeout : 3000 ms
Retries : 2.
The process does not use wait 3 seconds to start the first retry
but it reties after 1 sec of timeout.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31587
APAR: IV32418
-------------
Abstract: INFORMIX NCPOLLDATA.KNP_POLL_DATA_COLLECTION.POLLTIME ALWAYS SHOWS NULL ACCESSED BY NCP_OQL SERVICE NCIM
Description: ncpolldata.knp_poll_data_collection.POLLTIME in informix NCIM always shows NULL while accessed by ncp_oql service ncim interface.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV32418
APAR: IV33079
-------------
Abstract: NCP_DISCO CORE DUMPS WHILE EXITING IF NATTIMER STITCHER(RUNS
EVERY HOUR OUT-OF-THE-BOX) TRIGGERED DURING SAMETIME.
Description: If the disco process is getting recycled (stopped and restarted)
on top of the hour say 10am, and the NATTimer stitcher which
runs every hour out-of-the-box is triggered at same time will
cause Disco process to core while exiting.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33079
APAR: IV33114
-------------
Abstract: MODEL MANAGED STATUS WORK
Description: Managed status state transitions and propagation from chassis to subcomponents must follow a number of rules (as documented in the ITNM best practices guide.)
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33114
APAR: IV33118
-------------
Abstract: REMOTE POLLERS ARE NOT STOPPING REMOTELY
Description: During the stop of ncp_ctrl all the local children are
stopped and the remote processes are stopped via the ncp_ctrl slave but not
remote poller.
APAR: IV33478
-------------
Abstract: RECREATEANDSENDTOPOLOGY.STCH IS MISSING THE CALL TO SONMPLAYER
Description: During a rediscovery the SONMPLayer database is not
included in the list of arguments to the Merge Layers stitcher
in RecreateAndSendTopology.stch
leading to incorrect connectivity for devices advertising data via SONMP
such as Nortel switches.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33478
APAR: IV38462
-------------
Abstract: SCOPE.SPECIAL EXTENDED TO CHASSIS AND INTERFACES.
Description: "scope special" is an existing feature we extend to chassis and
interfaces.Please see following
RFE..http://www.ibm.com/developerworks/rfe/execute?use_case=viewRfe&CR_ID=31587
Changes to the scope.special table.
The following link describes the existing “special” table from the scope database :
http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/topic/com.ibm.networkmanagerip.doc_3.8/itnm/ip/wip/disco/reference/nmip_dsc_dsc_scope_db_schema_special_table.html
Following new data fields have been added in
NCHOME/etc/precision/default/DiscoSchema.cfg.
Column name Constraints Data type Description
m_Identifier Text Optional identifier for tracking
m_Priority int Optional priority used if used if there are multiple matches,
in which case the scope.special entry with the highest priority will be selected.
m_NonPingable int If set to 1 then the address will be selected even if could not be pinged
m_AdminInterface int type boolean Does this apply to interface entities Note: m_IsManagement is for chassis
m_ExtraInfo object type vblist Optional fields with which the arget entity could be enriched
If the NCHOME/etc/precision/DiscoSchema.cfg has been customized before, then
the existing file should be merged with
NCHOME/etc/precision/default/DiscoSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38462
APAR: IV44536
-------------
Abstract: EMPTY DATA IN TARGET SERVER AFTER MIGRATION (FROM ITNM 3.8.FP7TO ITNM 3.9.0)
Description: There is no error when run nmImport in target server. After run
nmImport, the network view get migrate to target server but 0 node. When
checking in databases, there is empty record for entiydata, chassis.
The export scripts require m_EncryptPasswords to be the second column in
the insert into config.settings insert.
If the NCHOME/etc/precision/ConfigSchema.cfg has been customized before,
then the existing file should be merged with N
NCHOME/etc/precision/default/ConfigSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44536
APAR: IV44547
-------------
Abstract: INCORRECT ICON IN NETWORK/HOPVIEW FOR FIREWALL DEVICE
Description: Discovery against Juniper Netscreen device and noticed that in
hopview it was not represented as firewall icon. topoviz.properties in
TIPHOME/profiles/TIPProfile/etc/tnm/ is missing this entry:
topoviz.image.Firewall=firewall.svg
Copy new value set into
TIPHOME/profiles/TIPProfile/etc/tnm/topoviz.properties.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44547
APAR: IV44549
-------------
Abstract: THE NCP_NCOGATE PROCESS NEEDS TO BE ABLE TO OPTIONALLY UPDATE AN
EVENT WHEN THE TOPOLOGY LOOKUP FAILED.
Description: The problem it addresses is the fact that the 3.8 gateway will
simply discard events that fail the topology lookup. This means that the
Impact policy which the customer has chained off the gateway's update will
never be triggered because the event is not updated.
Added the following to the gateway configuration file:
////////////////////////////////////////////////////////////////////////////////
// This is optional for events moving from ITNM to Omnibus that failed in the
// topology look up. An example of when you might use this is to update a flag
// in the event to indicate that ITNM has finished processing the event. This
// flag could then be used by an Impact policy to initiate further processing
// of the event.
//
// Note that after processing the EventFilter defined in config.ncp2nco will be
// applied.
//
create table config.topoFail
(
EventFieldMap object type vblist
);
// insert into config.topoFail
// (
// EventFieldMap
// )
// values
// (
// {
// NmosObjInst = 0,
// NmosEntityId = 0,
// NmosSerial = '',
// NmosCauseType = "eval(int, '$CAUSEUNKNOWN')"
// }
// );
If the NCHOME/etc/precision/NcoGateSchema.cfg has been customized before,
then the existing file should be merged with
NCHOME/etc/precision/default/NcoGateSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44549
APAR: IV47466
-------------
Abstract:UPDATE THE VERSION OF GSKIT USED BY ITNM 3.8 &3.9
Description: ITNM version 3.9 Fp3 and 3.8 FP7 upgraded with GSKIT 8.0.14.23.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47466
APAR: IZ89794
-------------
Abstract: SINGLE QUOTES REQUIRED WHEN USING LITERALS IN POLLING POLICY,
HOWEVER THE GUI REPLACES QUOTES WITH ', BREAKING POLICY.
Description: When creating a Poll Definition involving a literal string, the
literal must be placed within single quotes. If you don't place
the string in quotes,the poller throws the error "error in
template" ... I believe this is expected.
However if you quote the string, it appears the quotes are
replaced by the string "'". This happens if you change
between the tabs (eg "Trigger Threshold" to "Clear Threshold"
and back to "Trigger Threshold") while creating a new poll
definition. It also happens when you save the poll definition
and then bring that poll definition back up for editing. If you
save the definition and edit a 3rd time, the "&" in "'" is
replaced by "&". And this replacement of the "&" will go on
continuously.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ89794
APAR: IZ93148
-------------
Abstract: SINGLE QUOTES IN LDAP GROUP NAMES CAUSE AUTHENTICATION ERRORS IN
NETWORK VIEWS
Description: A user logs into TIP and attempts to access
the ITNM v3.8 Network Views tool. The user gets a error message that says
"unable to access database" even though the user has the appropriate
permissions.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ93148
APAR: IZ95110
-------------
Abstract: INCORRECT CONTAINMENT BUILDING FOR MANAGEMENT PORTS ON CISCO XR
IOS SOFTWARE DEVICES.
Description: Cisco XR IOS software devices only.
ContainResolvablePortEntities.stch does not have associated logic to handle
Management Ports that are listed under Entity-Mib and to integrate with
IF-MIB interface data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ95110
APAR: IZ95608
-------------
Abstract: NCP_POLLER DOES NOT HONOUR GETNEXT THROTTLING PARAMETERS
Description: GetNextSlowDown, GetNextBoundary, and GeneralSlowDown settings
don't currently have any effect. This APAR is to enable these
features.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ95608
APAR: IZ96931
-------------
Abstract: VIRTUAL DOMAIN CONNECTION BETWEEN PRIMARY AND BACKUP NOT ALWAYS
CORRECTLY
Description: virtual domain connection between primary and backup ITNM
servers on different machines does not always restored correctly.
In a ITNM failover setup with primary and backup on two
machines, after the virtual domain processes had connected, if
there occurs an connection issue, Virtual domain should recover
from this once the connection can be re-established, but this
did not always happen. So when there is a tcp connection between
the two virtual domain processes and the tcp connection is rese t
due to firewall/network issues, intermittently the system does
not reconnect properly which will result in the backup ITNM not
being updated.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ96931
APAR: IZ97548
-------------
Abstract: WHEN A INTERFACE IS EXCLUDED, AN ALERT IS STILL RAISED WHEN POLL
FAILS
Description: When using a post-discovery filter to eliminate specific
interface types, those interfaces are not included in model or
ncim as expected. However, when a poll without an interface
filter is run against that device - per the recommended
configuration - the poll result is not discarded, thus, if the
poll fails for a particular interface, an alert will be raised.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ97548
APAR: IZ98723
-------------
Abstract: DISCREPANCY ON EVENTMAP FOR NMOS PINGFAIL EVENTID
Description: NcoGateSchema.cfg and NcoGateInserts.cfg has discrepancy of the
eventMap for eventId 'NmosPingFail'.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ98723
APAR: IZ99325
-------------
Abstract: ACTIVE POLLING POLICY REMAINS ON THE BACKUP NCMONITOR DB AFTER
DELETED ON THE PRIMARY
Description: While deleting active polling policy on the primary, the
MonitorPolicies.<DomainName>.xml synchronized OK on the backup,
but not synchronized in backup ncmonitor database, where
the active polling policy remains and could generate poll data
if primary server down.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ99325
Prerequisites
IBM Tivoli Network Manager IP V3.8 must be installed before applying the Fix Pack..
IBM Tivoli Network Manager IP Edition 3.8 Fix Pack 7 is available as a separate install for Solaris, AIX, Windows and Linux.
This Fix Pack installer is cumulative and can be applied to any previous
maintenance level of Tivoli Network Manager IP V3.8. Some of the steps in this document may
have already been done if you applied a previous Fix Pack and don't need to be reapplied.
Ensure that there is approximately 1 gigabyte of free space on the drive
on which the product was installed
Note: When using the Windows command line, preface and suffix environment
variables with the percentage sign %, and replace each forward slash (/)
with a backslash (\) in directory paths.
For example, on Windows systems, $NCHOME is %NCHOME%.
While applying a FixPack, GUI properties file in $NCHOME/etc/precision/default and $TIPHOME/profiles/TIPProfile/etc/tnm/default will be overwritten. Back up these files before applying the fix pack and merge them with customized ones after applying the fix pack. See readme .txt file for detail.
Installation Instructions
Full details on how to install and perform post installation for this fixpack can be found in the INSTALL file which is downloadable from the link below...
Contacting IBM Support
Please use the IBM Tivoli Support website:
http://www-01.ibm.com/software/support/exchangeinfo.html
Prerequisites
Prerequisites
IBM Tivoli Network Manager IP V3.8 must be installed before applying the Fix Pack..
IBM Tivoli Network Manager IP Edition 3.8 Fix Pack 7 is available as a separate install for Solaris, AIX, Windows and Linux.
This Fix Pack installer is cumulative and can be applied to any previous maintenance level of Tivoli Network Manager IP V3.8. Some of the steps in this document may have already been done if you applied a previous Fix Pack and don't need to be reapplied.
Ensure that there is approximately 1 gigabyte of free space on the drive on which the product was installed
Note: When using the Windows command line, preface and suffix environment
variables with the percentage sign %, and replace each forward slash (/)
with a backslash (\) in directory paths.
For example, on Windows systems, $NCHOME is %NCHOME%.
See 3.8.0_INSTALL_FP0007.txt file for detail pre-req information.
URL | LANGUAGE | SIZE(Bytes) |
---|---|---|
3.8.0_README_FP0007 | US English | 83631 |
3.8.0_INSTALL_FP0007 | US English | 37655 |
3.8.0_INSTALL_NLS_FP0007 | US English | 103248 |
3.8.0_README_NLS_FP0007 | US English | 136985 |
Download package
Download | RELEASE DATE | LANGUAGE | SIZE(Bytes) | Download Options |
---|---|---|---|---|
3.8.0-TIV-ITNMIP-AIX-FP0007 | 13 Sep 13 | US English | 1367078175 | HTTP |
3.8.0-TIV-ITNMIP-Linux-FP0007 | 13 Sep 13 | US English | 1262573000 | HTTP |
3.8.0-TIV-ITNMIP-Solaris-FP0007 | 13 Sep 13 | US English | 1213985792 | HTTP |
3.8.0-TIV-ITNMIP-Windows-FP0007 | 13 Sep 13 | US English | 1075939399 | HTTP |
3.8.0-TIV-ITNMIP-zLinux-FP0007 | 13 Sep 13 | US English | 1218891477 | HTTP |
IZ47811, IZ65371, IZ77983, IZ78381, IZ80005, IZ81036, IZ84482, IZ85337, IZ85441, IZ86011, IZ86201, IZ86283, IZ87272, IZ87320, IZ87567, IZ89174, IZ89799, IZ89825, IZ89953, IZ89967, IZ90062, IZ90247, IZ90525, IZ91006, IZ91113, IZ91113, IZ92126, IZ92139, IZ92508, IZ92509, IZ93029, IZ94332, IZ94405, IZ94550, IZ94642, IZ94749, IZ95507, IZ95646, IZ95782, IZ96016, IZ96220, IZ96242, IZ96285, IZ96537, IZ96680, IZ53996, IZ96937, IZ97314, IZ97348, IZ97974, IZ98083, IZ98663, IZ98726, IZ98798, IZ99039, IZ99288, IZ99474, IZ99578, IZ99855, IV00076, IV00446, IV00672, IV00808, IV00923, IV00925, IV00926, IV01100, IV02909, IZ68880, IZ73532, IZ74467, IZ76369, IZ77010, IZ77691, IZ77702, IZ77758, IZ78138, IZ78155, IZ78279, IZ78285, IZ79681, IZ80102, IZ80897, IZ80898, IZ81206, IZ81475, IZ82383, IZ82822, IZ82837, IZ83476, IZ83740, IZ83742, IZ84425, IZ85090, IZ85113, IZ85321, IZ85606, IZ85722, IZ85782, IZ86283, IZ86825, IZ86871, IZ87135, IZ87165, IZ87258, IZ87584, IZ87910, IZ88605, IZ88853, IZ88972, IZ89301, IZ89818, IZ92174, IZ92183, IZ92189, IZ92191, IZ92193, IZ92196, IZ92197, IZ92199, IZ92484, IZ84399, IZ85921, IZ73447, IZ61115, IZ64903, IZ56490, IZ67528, IZ68078, IZ62735, IZ68893, IZ73448, IZ73449, IZ73458, IZ73452, IZ73464, IZ53043, IZ56768, IZ60584, IZ62664, IZ63700, IZ73469, IZ63085, IZ73470, IZ64092, IZ64844, IZ65338, IZ65525, IZ65569, IZ73472, IZ65302, IZ65516, IZ66759, IZ58862, IZ46979, IZ62710, IZ66357, IZ62536, IZ62246, IZ40084, IZ41729, IZ42752, IZ42959, IZ44508, IZ45657, IZ45660, IZ46682, IZ47606, IZ47811, IZ48222, IZ48538, IZ48657, IZ50360, IZ50824, IZ51286, IZ51645, IZ52419, IZ52651, IZ52691, IZ52872, IZ53557, IZ53563, IZ53873, IZ53996, IZ54578, IZ55343, IZ55385, IZ55391, IZ55393, IZ55406, IZ55574, IZ55587, IZ55628, IZ56672, IZ60555, IZ61689, IZ61960, IZ62250, IZ63045, IZ63765, IZ64152, IZ65922, IZ65654, IZ60181, IZ09389, IZ34147, IZ36915, IZ39304, IZ39828, IZ39917, IZ40064, IZ40796, IZ41051, IZ41214, IZ41892, IZ42192, IZ42332, IZ42347, IZ42604, IZ42619, IZ43671, IZ44203, IZ44277, IZ44747, IZ44824, IZ44924, IZ45266, IZ45326, IZ45327, IZ46821, IZ40046, IZ58193, IZ68880, IZ68877, IZ69530, IZ69749, IZ69206, IZ72170, IZ73267, IZ82438, IZ67528, IZ74221, IZ74228, IZ74277, IZ74697, IZ74503, IZ73165, IZ82445, IZ74732, IZ74946, IZ74882, IZ74914, IZ82448, IZ75610, IZ68758, IZ75836, IZ82449, IZ75910, IZ74503, IZ75487, IZ76402, IZ82450, IZ76061, IZ76442, IZ82451, IZ73532, IZ75519, IZ77986, IZ78102, IZ77246, IZ78374, IZ95300