A change introduced by 3.9.0-TIV-ITNMIP-FP0004 might negatively
affect existing product function.
Please refer to APAR(s) IV60422, IV60742, IV61404, IV61701 and IV62920 for a
description of the problem(s) and corrective action(s).
APAR:IV61404 APAR:IV60742 APAR:IV60422 APAR:IV61701 APAR:IV62920
Evaluate these APARs for the potential impact in your environment.
****************************************************************************
Summary of the Enhancements included in this Fix Pack.
Poller Improvements - Numerous improvements in the Poller related to start up performance and for monitoring Poller load. Poller metrics are introduced that can be output as bar charts on the command-line interface.
OSDB Support
APAR : IV22788
-----------------------
Abstract: UNMANAGE/MANAGE ACTION CAUSES BACKUP POLLER TO POLL DEVICE.
Description: Unmanage/manage action causes backup poller to poll device.
In a failover environment with a Primary and Backup Poller
running, with the Primary domain healthy and acting primary, if
the user unmanages, then manages a device, the backup poller
will begin polling that device, and raising duplicate events.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22788
APAR : IV23287
-----------------------
Abstract: MYSQL DB USING TOO MUCH CPU CREATING REPORTS
Description: DB push CPU usage to 100% because it have issues with
inner joins, group by and order by on SQL statements that
retrieve large amounts of data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV23287
APAR : IV25953
-----------------------
Abstract: FIND IN MAP FUNCTION FINDS ELEMENTS THAT ARE NOT IN MAP
Description: Attempting to search for a device from a network view finds the
device even if it is not in that view.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV25953
APAR : IV26760
-----------------------
Abstract: DEFAULT INTERFACE PING POLL DEFINITION HAS 'IFADMINSTATUS'
FILTER CASUING POLLER NOT TO POLL VALID IPADDRESSES.
Description: The 'Default Interface Ping' Poll definition has following
filters under Interface filter tab against 'ncim.interfaces'
table i.e. ipAddress IS NOT NULL ifAdminStatus = 'up'.
There could be many cases where we have valid IPAddress for an
interface where ifAdminStatus is not populated. All such
scenarios won't be polled by 'Interface Ping' policy.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26760
APAR : IV27702
-----------------------
Abstract: NETWORK VIEWS ARE TOO SLOW TO OPEN DUE TO HUGE TOPOLOGY
Description: Customers with huge topology struggle with performance due to the
long time it takes for the data to be retrieved from the database.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV27702
APAR : IV28121
-----------------------
Abstract: NCP_PERL FAILS WITH ERRORS IN WINDOWS APPLICATION ERROR
Description: ncp_perl.exe failed and the following error created in windows
application log. Faulting application name: ncp_perl.exe xxxxxxx
time stamp: 0x4d52b578 Faulting module name: libxxxxxx.dll..
http://www-01.ibm.com/support/docview.wss?uid=swg1IV28121
APAR : IV29828
-----------------------
Abstract: WEBTOOL MANUAL LOGON FAILS WHEN M_PASSWORD HAS SPECIAL CHARACTERS
Description: Login or authorization failure using Webtools when attempting a
manual connection. Webtools manual login fail when password contains special
characters.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV29828
APAR : IV30425
-----------------------
Abstract:ON FAILOVER/FAILBACK, ACTIVE POLLER SHOULD CONTINUE POLLING
UNTIL NEW POLLER IS READY TO TAKE OVER
Description: When NCIM database is remote, Poller process takes very long
time to sync with NCIM and to evaluate the scope during
start-up. The start-up time could vary from 30 mins to 3 hours
depending upon domain size, number of active policies, number of
entities to monitor and Interface/Device filters etc.
Same delay is applicable in a failover scenario, when Primary
goes down, Backup domain takes over in the given configured
period - default is 5 minutes. But Poller isn't doing any
monitoring as the poller synchronization with NCIM and scope
evaluation of Poll policies/definitions could take few hours.
Same is true for failback scenario. On failback, the active Poller was sending it's heartbeat
once the monitors were activated, but before they started to
poll resulting in a gap in monitoring.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30425
APAR : IV31296
-----------------------
Abstract: ASSOCADDRESS AGENT TO USE IPADENTADDR VALUE INSTEAD OF THE INDEX
FOR THE IPADDRTABLE ENTRY.
Description: Unable to discovery Redware Alteon Application Delivery Controller (ADC) and
VADC (Virtual ADC) properly. Introduce a new option called UseSnmpIpValue for
AssocAddres agent to use the actual ipAdEntAddr value instead of using the index of the
ipAddrTable entry, if the device's matches the OID filter defined in this flag. By default, the
agent will use the IP value from ipAdEntAddr column for Alteon devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31296
APAR : IV31587
-----------------------
Abstract: SNMP TIMEOUT
Description: For every first SNMP query to determinate if the device responds
to SNMP, the timeout configured is not used. The process does not use wait 3 seconds to
start the first retry but it reties after 1 sec of timeout. During the initial SNMP credential
discovery the configured timeout and retries for a given IP address were not always
used. Meaning that sometimes ITNM failed to gain SNMP access
to devices that were responding slowly.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31587
APAR : IV31984
-----------------------
Abstract: IN A DISTRIBUTED ENVIRONMENT REMOTE PROCESSES UNABLE TO
RE-ESTABLISH CONNECTION WHEN THE BROKER DAEMON RESTARTED
Description: In a distributed environment - for e.g.
ServerA : ITNM Core except ncp_model
ServerB : ncp_model & NCIM database
When the broker (ncp_brokerd) on ServerA is restarted for
whatever reason - the processes on ServerB notices a
disconnection, but unable to re-establish connection with new
broker instance upon restart.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31984
APAR : IV32386
-----------------------
Abstract: ITNM PROCESSES FAIL TO STOP AFTER DB2 DATABASE IS RECYCLED.
Description: DB2 database is recycled then some of the ncp processes are not
terminated with itnm_stop script. The proccess like ncp_model,
ncp_poller and ncp_g_event are not terminated with itnm_stop
means process are still running after itnm_stop script is completed.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV32386
APAR : IV32747
-----------------------
Abstract: NCP_POLLER CORE AT SHUT DOWN OF ITNM
Description: When shutting down the ncp_ processes, typically via
itnm_stop ncp, a core file is generated for the ncp_poller
process. When shutting down the ncp_ processes, typically via
itnm_stop ncp, a core file is generated for the ncp_poller
process when network contains devices managed via SNMP v3
and at least one SNMP poll policy is active.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV32747
APAR : IV33079
-----------------------
Abstract: NCP_DISCO CORE DUMPS WHILE EXITING IF NAT TIMER STITCHER (RUNS
EVERY HOUR OUT-OF-THE-BOX) TRIGGERED DURING SAMETIME.
Description: If the disco process is getting recycled (stopped and restarted)
on top of the hour say 10am, and the NATTimer stitcher which
runs every hour out-of-the-box is triggered at same time will
cause Disco process to core while exiting.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33079
APAR : IV33095
-----------------------
Abstract: TOPOVIZ.TRACE.LEVEL VARIABLE MISSING IN TOPOVIZ.PROPERTIES
CONFIG FILE
Description: topoviz.properties config file does not contain variable
topoviz.trace.level. Making it hard for users to adjust the
trace message level. missing parameter from properties file
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33095
APAR : IV33114
-----------------------
Abstract: MODEL MANAGED STATUS WORK
Description: Managed status state transitions and propagation from chassis
to sub components must follow a number of rules (as documented in
the ITNM best practices guide.)
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33114
APAR : IV33118
-----------------------
Abstract: REMOTE POLLERS ARE NOT STOPPING REMOTELY
Description: During the stop of ncp_ctrl all the local children are stopped and the remote
processes are stopped via the ncp_ctrl slave.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33118
APAR : IV33128
-----------------------
Abstract: NETWORK VIEWS FAIL TO HANDLE INVALID FILTERS GRACEFULLY
Description: If a filter is invalid it throws exception causing the Wetop
Entity registration to terminate, hence some views have no
status. Status not visible on some or all nodes in a network view.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33128
APAR : IV33250
------------------------
Abstract: INVALID OID REQUESTED WHEN INTERFACE FILTERING IS ENABLED AND
ALL IN-SCOPE DEVICES ARE UNMANAGED AND REMANAGED
Description: Enable SNMP polling and apply an interface filter. The
interface filter prevents the poller from simply walking the
interface index and ensures that it has to construct the
interface index as part of the poll.
Select all the hosts that comprise the entire scope of the poll
policy. Then toggle the managed status of the devices, i.e.
unmanage them all, and then remanage them all.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33250
APAR : IV33478
-----------------------
Abstract: RECREATEANDSENDTOPOLOGY.STCH IS MISSING THE CALL TO SONMPLAYER
Description: During a rediscovery the SONMPLayer database is not
included in the list of arguments to the Merge Layers stitcher
in RecreateAndSendTopology.stch leading to incorrect
connectivity for devices advertising data via SONMP such as
Nortel switches.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33478
APAR : IV33533
-----------------------
Abstract: STRUCTURE BROWSER SEARCH FAILS TO FIND MATCH VLANS
Description: VLANs do not seem to be included in the search pattern of the
Structure Browser. The search request statement needs to be
altered to query the VLANs, VPNs, etc..
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33533
APAR : IV33578
-----------------------
Abstract: THE ITNM_DISCO.PL CORE DUMP WHEN IT IS STOPPED BY CTRL+C
Description: The itnm_disco.pl core dump when interrupted by Ctrl+C.
The issue is caused by the way that AIX and perl handle signals. On Linux and Solaris the
signals end up being called within the main thread but on AIX they can get called on the
IO thread. In addition the use of multiple signal handlers can result in inconsistent data ( i.e. cores ) according to the perl manual. The ncp_perl script has a
signal handler and as the perl script also had a signal handler it caused a core.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33578
APAR : IV33996
-----------------------
Abstract: ITNM REJECTS LINKS DISCOVERED BY SONMP STITCHER
Description: Incorrect/Missing layer 2 connectivity between Nortel Avaya switches. In
SONMPLayer.stch, ITNM rejected those links that coming from devices with
unknown/unsupported chassis type. The code was too restrictive to devices which has certain known chassis type number.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33996
APAR : IV34108
-----------------------
Abstract: DOCUMENT THE "MONITORING POLICY DETAILS" REPORT
Description: The "Monitoring Policy Details" report does not show a list of
nodes to be queried as documented. Instead it shows a list of
nodes for a policy that has the store option set, and that is a
prerequisite for getting any report.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV34108
APAR : IV34113
-----------------------
Abstract: ITNM 3.9 NETWORK VIEW .SVG AND .PDF CANNOT BE SAVED
Description: When loading a Network View and clicking the save icon. If .svg
or .pdf format are selected, an error message "cannot be saved"
is displayed and a 0 length file created.
Unable to save network views as pdf or svg format
http://www-01.ibm.com/support/docview.wss?uid=swg1IV34113
APAR : IV35501
------------------------
Abstract: DUPLICATES IN 'SHOW CONNECTIVITY INFORMATION' GUI FOR DEVICE
Description: For VLAN (or other sub-connections), its containing entities
will be displayed in the 'show connectivity' GUI. The filter
method iterate through the connections to make sure only one
instance of such is displayed but sometimes it doesn't filter
correctly.The problem will appear as an identical connections.
Investigation into model and ncim show that there are not
duplicate interfaces to be found.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV35501
APAR : IV35661
-----------------------
Abstract: GET_POLICIES.PL DOES NOT IMPORT POLICY INTERFACE FILTER WHEN
MIGRATING FROM 3.8 TO 3.9
Description: When trying to migrate policies from 3.8 to 3.9 ,
policy interface filter is lost. In ITNM 3.8 interface filter is stored on policy.ifScopeId
column. In 3.9 interface filter is defined at template level (template.ifScopeId).
The migration process:3.8 - ncp_perl get_policies.pl -from domain=NCOMS -to
file=get_policies_NCOMS.dat. 3.9 - ncp_perl get_policies.pl -from
file=get_policies_NCOMS.dat -to domain=NCOMS
fails to transfer the interface filter (policy.ifScopeId -> template.ifScopeId).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV35661
APAR : IV35842
-----------------------
Abstract: POLLER THROWS UNSUPPORTED DATABASE TYPE: ORACLE11 WHEN POLLING
IS FILTERED ON A VIEW.
Description:
Create a snmp policy. Filter the policy on a view created in the
Network Views. Save the policy.
In the ncp_poller.DOMAINNAME.trace we get the following error
message: Exception in thread "Thread-21" java.lang.RuntimeException:
Unsupported database type: oracle11 at xxxxxxx.java:66.
The poll might succeed, but in some cases they will not.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV35842
APAR : IV36091
-----------------------
Abstract: SNMP COMMUNITY STRING INDEXING FAILED ON NORTEL DEVICES AND BAD
SNMP COMMUNITY STRING REPORTED
Description: NortelSwitch agent uses community string indexing to query FDB data,
causing SNMP authentication failure alarm generated. It has been found out that
Nortel/Avaya switches that supports standard FDB MIBs do not support community string
Indexing. The NortelSwitch agent code has been updated to avoid using community string
indexing if the device do not support private FDB MIBs and only supports standard FDB
MIBs. NortelSwtich agent would use community string indexing only if the device supports
private FDB MIBs.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36091
APAR : IV36109
-----------------------
Abstract: DISPLAYING THE DEVICE ICON IN LEGACY MODE IS NOT WORKING.
Description: Displaying the Device icon in Legacy mode is not working as per
the below doc to change the device icon as like ITNM 3.8 version
http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/index.jsp?topic=%2Fcom.ibm.networkmanagerip.doc_3.9%2Fitnm%2Fip%2Fwip%2Fadmin%2Ftask%2Fnmip_adswitchingtov38vismode.html
Label is coming on top the device icon,so can not select the
label to move or changes the position. When network view map was displayed in legacy
mode, labels appeared on top of the icons in the center.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36109
APAR : IV36368
-----------------------
Abstract: RUNTIME EXCEPTION ERROR DISPLAYED WHEN SELECTING "DEVICE
MEMBERSHIP" LINK FOR A POLL POLICY.
Description: When selecting the "device membership" link for poll policy with
a device filter that uses either the displayLabel or description
field from the mainNodeDetails table in ncim, the following
error is displayed:
CTGTD1000E An error occurred while processing the request to the server.
Detail: RuntimeException Error executing query: Getting device membership for policy:
Ambiguous column(displayLabel).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36368
APAR : IV36581
-----------------------
Abstract: PREVIEW OF COLLECTION VIEWS IS NOT ORDERED AND IS HARD TO
SCAN/SEARCH
Description: Preview of collection views is not ordered and is hard
to scan/search When we have to create a Network View and I select
as type "VPN" the order of available collection is not
alphabetical or numerical, so it is very difficult to identify and then select a
certain Virtual Circuit (VC).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36581
APAR : IV36679
-----------------------
Abstract: NULLPOINTER EXCEPTIONS REGISTERED ON GUI WHEN SEARCHING AN
EMPTY DATASTORE
Description: Open a NetworkView viewType which contains an empty view tree,
search for a view name. NullPointer Exceptions registered on GUI when searching an
empty data store.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36679
APAR : IV36728
-----------------------
Abstract: AEL LIST NOT UPDATED WHEN "SHOW NETWORK VIEWS TREE?" DISABLED
Description: Replication steps:
1) open a "Network Health View" window. Select device or group
and AEL is updated.
2) Click the top right down arrow and select personalize.
Disable the "Show Network Views Tree?""and set "Map ID" to 1.
3) Save and again select devices, AEL will not update in Health View, personalize the
network views page to display map only, not showing the network views tree. Then
click on devices on the map, AEL won't filter by device selected.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36728
APAR : IV36856
-----------------------
Abstract: MEMORY USAGE REPORT USES INCORRECT POLL POLICY
Description: The "Memory usage report" uses the incorrect policy.
The code, and consequently the documentation are incorrect as the
"Memory usage report" does not depend on stored data from the
CiscoMemoryPool policy.
http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/index.jsp?topic=%2Fcom.ibm.networkmanagerip.doc_3.9%2Fitnm%2Fip%2Fwip%2Fref%2Freference%2Fnmip_ref_report_memoryusage.html
The "Memory usage report" uses the memoryPoll policy.
The report uses a policy called ciscoMemoryPoll that don't
store data on database and results in an empty report
http://www-01.ibm.com/support/docview.wss?uid=swg1IV36856
APAR : IV37074
-----------------------
Abstract: POLLER PRODUCES A LARGE AMOUNT OF EVENTS AFTER STARTUP
Description: The poller generates hundreds of Link State change events on
startup. Most of these events may be for empty ports or access
ports if the Link State polls did not filter out these
interfaces, and of little value. With the introduction of FP02 the initial state of all polls are
determined by existing events. If there are no existing events then the initial state is
determined to be "clear". In networks where ports are not yet used, but have not be
placed into AdminStatus down, having the initial state set to clear can result in
unnecessary Snmp Link State down events. Previously the first poll would have been used
to establish the initial state for the Snmp Link State polls, resulting in no link down events.
for customers who do not set their port's AdminStatus this was the desired behavior.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV37074
APAR : IV37322
-----------------------
Abstract: INCORRECT VLAN MODELING WITH HUAWEI SWITCHES
Description: Incorrect VLAN modelling with Huawei switches via StandardSwitch agent. The
Huawei device uses dot1dBasePortIfIndex to map the port number (PortList) into interface
index. StandardSwitch agent code does not perform this mapping while discovering VLAN
information.
The StandardSwitch agent has been updated to add the port to ifIndex mapping into the
StandardSwitch agent while parsing dot1qVlanCurrentEgressPorts data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV37322
APAR : IV37587
-----------------------
Abstract: MIB GRAPH DOES NOT RENDER
Description: In a failover setup using a non replicating NCIM the backup
poller can interfere with the proper scope evaluation of the primary poller
Error message:
"No data was received from server after multiple polling
intervals. Please check the graph configuration, or see the
log for more information.
The backup Poller would evaluate it's scope while in stand by
mode and update the scopedEntity table. This table would
then be used by the primary Poller when re-evaluating scope,
resulting in entities to be missed. This issue impacts Mib
Grapher and regular policies.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV37587
APAR : IV37779
-----------------------
Abstract: MINOR CODE FIXES FOR ITNM_PATHTOOL.PL
Description: Added function
prototype. Added checks for null values. Function called too early to
check prototype. Use of uninitialized value in pattern match (m//).
Use of uninitialized value in concatenation (.) or string.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV37779
APAR : IV38084
-----------------------
Abstract: WARNING IN NCP_POLLER LOGS "CANNOT CAST ATOMIC VALUE"
Description: Following message seen in the poller logs:
Warning: W-RIV-002-043: [3982490528t] xxxxxx.cc(507)
Cannot cast atomic value from parsed to stored ! Clause & p2
evaluated to 'inbandwidth' of type String which could not be.
This is a cosmetic warning message and should be suppressed poller prints warning
message when poll incomplete.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38084
APAR : IV38239
-----------------------
Abstract: MISSING LINK DUE TO INVALID ARP ENTRY FROM NETSCREEN DEVICE
Description: Missing link from NetScreen device due to Invalid ifIndex found
in ipNetToMediaPhysAddressArp entry was rejected by ArpCache
agent because the agent failed to find the interface data with
ifIndex=0, which is the first numeric number from the index of
ipNetToMediaTable. Missing connectivity due to invalid ifIndex found in
ipNetToMediaPhysAddressArp entry in NetScreen device was
rejected by NetScreenArpCache agent because the agent failed
to find the interface data with ifIndex=0, which is the
first numeric number from the index of ipNetToMediaTable.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38239
APAR : IV38395
-----------------------
Abstract: FIND IN NETWORK VIEW TOOL FAILS FROM DEVICE ICON IN HOP VIEW
Description: On some occasions the attempt to right click a device icon from
the Network Hop View and select "Find in Network View" can fail.
Other occasions the attempt succeeds but can take as long as 10
minutes with large view sizes and containment.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38395
APAR : IV38462
-----------------------
Abstract: SCOPE.SPECIAL EXTENDED TO CHASSIS AND INTERFACES.
Description: "scope special" is an existing feature we extend to chassis and
interfaces. Please see following RFE..
http://www.ibm.com/developerworks/rfe/execute?use_case=viewRfe&CR_ID=31587
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38462
APAR : IV38610
-----------------------
Abstract: ATTEMPTING TO CREATE A COPY OF MIB GRAPHER FAILS
Description: In MibGraph, click on the copy button, new mibgraph appeared
with same configuration. Click on copy button from this new
mibgraph, the next copy lost all the configuration information.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38610
APAR : IV38617
-----------------------
Abstract: MODIFYING POLL POLICIES POLLER STATUS ICON TO CHURNS
Description: Poll GUI has been showing the spinning "Status Pending". This
happens after modifying the poll policy.
The status never changes even after restarting browser and
restarting the TIP server. After modifying poll policy, Poll GUI showed the spinning "Status
Pending" and never changed.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38617
APAR : IV38618
-----------------------
Abstract: MIB GRAPHER UNNECESSARILY POLLS WHEN IN HISTORICAL MODE
Description: When it's set to draw historical graph, mibgrapher also sent
realtime poll requests. Although data is discarded, the poller
should not be polling the network.
Realtime polling also runs when mibgraph is running in historical mode
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38618
APAR : IV38744
-----------------------
Abstract: AFTER APPLYING ITNM V3.9 FIX PACK 3, NCP_MIB CORE DUMP FILE. REFERENCE
APAR IV27953.
FAULTY MEMORY HANDLING RESULTS IN NCP_MIB CORE DUMP FILE.
Description: This APAR is created as AE/MDV APAR with "MDVRGRS" class.
APAR IV27953 APAR: MDVPARTL 3.9.0-TIV-ITNMIP-FP0003
After applying ITNM v3.9 Fix Pack 3, ncp_mib cores. Reference
APAR IV27953. Faulty memory handling is leading to
undefined behavior which results in
occasional cores during mib processing on some platforms.
This problem originated in FP03.ncp_mib core dumps due to memory corruption when processing a MIB variable defined
as <mibVariable> = { <definedMibVariable> <value1> <value2>
... } as opposed to simply { <definedMibVariable> <value1>}.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38744
APAR : IV38974
-----------------------
Abstract: STATUS MISMATCH BETWEEN THE NETWORK VIEWS AND NETWORK VIEW TREE
Description: Network View tree highest severity status is less than or not
as severe as some of the contents/entities of the network view.
The Network View Tree and the Network View construct the status
filter based on different criteria (event field):
Network View Tree -> NmosEntityId IN (722382, ...)
Network View -> NmosObjInst IN (722382, ...)
When the event has the NmosEntityId and NmosObjInst set to
different values: NmosEntityId 86958 Vlan interface [Vl686] ifIndex 20
NmosObjInst 722382 main node , the Network View Tree and the
Network View will show different severity status.
Both (view and tree), should build the filter using the same
event field.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38974
APAR : IV39072
-----------------------
Abstract: ATOMIC CAST FAILURES FOR HIGH DISCARDRATE POLICY USING INTEGER
Description: The High Discard Rate policy has incorrect expression.
It was casting results to int when it should have been long64.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39072
APAR : IV39195
-----------------------
Abstract: MONITORED DEVICE DETAILS REPORT PDF FORMAT IS NOT CORRECT.
Description: Monitored Device Details report format is not correct when
exporting as a PDF format.
To replicate the issue:
Common Reporting--> Public Folders > Network Manager >
Monitoring Reports --> Run Monitored Device Details as PDF
format. Customer views monitored device details report in PDF format
and report is broken up into many pages with too much
white space between charts.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39195
APAR : IV39203
-----------------------
Abstract: DEVICE AVAILABILITY SUMMARY REPORT HAS WRONG UPTIME AND DATE IS
MISSING.
Description: Device Availability Summary report showing wrong SysUpTime and
Uptime, also there is no start Date-time and End date-time in
the report.
Replication Steps:Common Reporting --> Public Folders > Network
Manager > Summary Reports --> Run the Device Availability
Summary report. Report does not include the Start and End time of when the
user ran the report. Also the sysUpTime displayed in the
header is incorrect.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39203
APAR : IV39428
-----------------------
Abstract: ITNM GUI CONSTRUCTS WRONG FILTER FOR ALERT VIEWS
Description: ITNM GUI constructs wrong filter for Alert views. When opening
the AEL from the Network View the creation filter is incorrect. In some cases there is a
mismatch between the status in the
Network View Tree and the devices in the Network View
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39428
APAR : IV39551
-----------------------
Abstract: CORE DUMP OF NCP_G_EVENT ON
SOLARIS IN ANY CURRENT RELEASE OF 3.9.
Description: Core dump of ncp_g_event on Solaris whilst performing isolated
suppression.
Memory corruption is occurring as a result of a bug in SunStudio
11. There appears to be a problem with the std::deque STL
container in the version of SunStudio used to build 3.9. This is
Oracle issue CR 6363210: std::deque memory corruption. This is
fixed in subsequent patched versions of SunStudio, to be
integrated into the build system for future releases of ITNM.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39551
APAR : IV39822
-----------------------
Abstract: POLLER FALLS BEHIND ON SNMP BANDWIDTH POLLS WHEN NOT USING AN
INTERFACE FILTER
Description: Poller falls behind on Snmp Bandwidth polls when not using an
interface filter in two scenarios :
a) During start-up
b) Upon completion of discovery while processing topology updates.
And it takes minutes/hours to recover depending on the number
of monitors in the polled scope.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39822
APAR : IV39998
-----------------------
Abstract: NETWORK MANAGER IP VIEWS OUT OF MEMORY
Description: ITNM 3.9 FP3 - This APAR is created as AE/MDV APAR with
"MDVPARTL" class.
MDVPARTL 3.9.0-TIV-ITNMIP-FP0003
Currently the ITNM WebGUI is not translating mainNode only
views into aggregated NmosObjInst filters, this is causing a
functional issue whereby device specific views are not
generating alerts on each devices containment, rather just on
the device itself. There is also a knock-on performance problem
whereby, when endNodes="true" is set the generated filter is
based on the full set of device containment as NmosEnityId
rather than the more efficient NmosObjInst. "Hung Thread" and
"Out-of-Memory" errors in logs; followed by system slowdown.
In extreme cases the UI/Tip server java process crashes.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV39998
APAR : IV40185
-----------------------
Abstract: DEVICES MISSING COLLECTOR DISCOVERY COLLECTOR ADDRESSTRANSLATION
Description: Customer has collector only discovery.
Missing device is in CollectorDetails.returns
seen in CollectorInventory.returns, but is missing an entry for it's own IP address in the
'm_ExtraInfo' => {'m_AssocAddress' => [section.so ip is not found here
select * from translations.collectorUniqueToWorkAddress where
m_WorkAddress = or
select * from translations.collectorUniqueToWorkAddress where
m_UniqueAddress=
and missing from scratchTopology.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV40185
APAR : IV40211
-----------------------
Abstract: DBI_FACTORY DOES NOT INITIALIZE CLIENT_LOCALE REQUIRED FOR
INFORMIX ON WINDOWS.
Description: Windows Operating System with Informix database
containing multibyte characters.
If you have a Windows installation of ITNM using the default
Informix (IDS) database and you have data in the IDS database
that includes multibyte characters, then using the perl scripts
to interact with the data will fail.
For example, if you name your Network Views using Japanese
characters, then use get_network_views.pl or
ITNMExportNetworkViews.pl to export the Network Views, the
script will fail to export those views with Japanese characters.
You may receive an error from the script such as:
DBD::ODBC::st fetchrow_hashref failed: [Informix][Informix ODBC
Driver]Inexact character conversion during translation.
(SQL-HY000).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV40211
APAR : IV40479
-----------------------
Abstract: DEADLOCK OCCURS WHEN MULTIPLE THREADS TRY TO LOCK BROKER
CONFIGURATION FILE LEADING TO HANGING.
Description: This behavior occurs specially on Windows systems, where
both ITNM and ITM agent for ITNM are installed, but might
happen on other operating systems.
When deadlock occurred , error messages like:
Error: An unrecoverable error occurred. Please contact IBM
Support.
Fatal Error: Unable to lock mutex. found in file xxxxxxxx.cc at
line 112 - Invalid argument in mutex created from xxxxxxxxx.cc.
Application terminating due to error
are generated in logs associated with processes that are trying
to lock the config file.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV40479
APAR : IV40995
-----------------------
Abstract: INCOMPLETE LOGIC UNDER RESOLVE VRRPESSES.STCH CAUSES
VIRTUAL VRRP IPADDRESS TO BE MAIN CHASSIS IP OF THE DEVICE
Description: VirtualIP of VRRP assigned as main chassis IP when it should
not.During stitching the stitcher 'ResolveVRRPAssocAddresses.stch'
that processes all records from Nokia VRRP & other agents is
supposed to find MasterIp and make that as BaseAddress if we
have found the device in the discovery Phase1 using Virtual IP
Address, but it does not do that extensive check, resulting
mainnode base address with Virtual IPAddress.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV40995
APAR : IV41267
-----------------------
Abstract: ON RESTART MODEL SHOULD CHECK FOR (AND FIX) MISSING
DOMAINMEMBERS ENTRIES IN NCIM
Description: If rows are deleted from the domain Members table this can result
in missing entities and links in the network views. Upon a
re start the model process does not detect this missing data and
will therefore not restore the missing entities and links to the views.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV41267
APAR : IV42617
-----------------------
Abstract: DOMAIN-SPECIFIC DBLOGINS.CFG MANDATORY FOR POLLER WITH
MULTIPLE DOMAINS
Description: Polling failover failed if domain specific version of
DbLogins.cfg didn't exist.
The get_policies.pl script is used to write changes in Poll
Policies to the domain's version of MonitorPolicies.xml.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV42617
APAR : IV42667
-----------------------
Abstract: SAE AUTOMATION THAT SHIPS WITH ITNM'S SERVICE AFFECTING EVENTS CAPABILITY DOC UPDATE
Description: Document update on ITNM's Service Affecting Events capability can be
deployed correctly in a multi-tier OMNIbus environment.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV42667
APAR : IV42743
-----------------------
Abstract: ENTITYCOUNT FIELD FROM NCIM.DOMAIN SUMMARY IS NOT RELIABLE
Description: The entityCount field from ncim.domainSummary table should store
the number of entities in the domain.
However, count(*) from ncim.entity table is not equal
with entityCount value
This value suppose to be updated at the end of each discovery.
The problem occurs only on ITNM 3.9 version.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV42743
APAR : IV42747
-----------------------
Abstract: SERIAL NUMBER ATTRIBUTE IS MISSING FOR JUNIPER ENTITIES
Description: Serial Number info is missing for Juniper Entities. ITNM Juniper
agent does retrieve the card serial number info but gets
removed at the stitcher level. Card serial number info retrieved from Juniper agent was
removed at the stitcher level.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV42747
APAR : IV43090
-----------------------
Abstract: FAILOVER NCP_G_EVENT SERVER ATTEMPTING TO UPDATE OMNIBUS PRECISION FIELDS
Description: The SAE plugin in ncp_g_event on the backup server attempts to
update OMNIbus after discovery completion. These transactions
should not take place from the backup and are causing Warning
messages: ncp_g_event.NCOMS_B.trace:Wed May 15 16:21:25 2013 Warning: A
generic error has occurred found in file xxxxxxx.cc at line xxxx
General failure: Failed to retrieve results for query..At the end of a discovery, the gateway
on the primary updates the SAE information in Omnibus from the primary gateway.
ITNM failover GW also try to update this information. It should not do this.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV43090
APAR : IV43140
-----------------------
Abstract: CREATEMPLSPE.STCH BAD EVAL LINE 534 CAUSING DISCO SYNTAX ERROR
Description: CreateMPLSPE.stch stitcher, line 534 has a syntax eval error.
Error causes syntax error in line 29 in disco log file.
where
(
m_BaseName = eval(text,'$entName')
AND
m_IpAddress = (eval,text,'$bgpAddress')
);
http://www-01.ibm.com/support/docview.wss?uid=swg1IV43140
APAR : IV43184
-----------------------
Abstract: NAT ADDRESS SPACE IS NOT POPULATED CORRECTLY.
Description: NAT address space is not populated correctly and m_AddressSpace is missing for some of the entities.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV43184
APAR : IV43870
-----------------------
Abstract: NCP_POLLER STOPS POLLING AND LOGS OUT-OF-MEMORY WHEN
COLLECTION RATE EXCEEDS STORAGE RATE
Description: ncp_poller stops polling and logs Out-of-memory when collection
rate exceeds storage rate. The poller buffers data in memory when it is unable to store
due to database connection or collection rates exceed storage
rates. The buffer increases until memory is exhausted during prolong database outages, or
excessive polling load, the Poller would continue to collect poll data and store in
a memory queue. This queue would continue to grow until
poller ran out of memory.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV43870
APAR : IV43944
-----------------------
Abstract: DISCOVERY TIME INCREASE AFTER EACH FULL DISCO PROCESS.
Description: The problem is that discovery keeps on taking longer and longer the more
often it runs.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV43944
APAR : IV44090
-----------------------
Abstract: HOP VIEW, SUBNET CONNECTIVITY IS ONLY SHOWING THE SEED DEVICE.
Description: In the hop view, if I choose subnet view, only the seed device
is displayed. However if I go to the network view and choose
subnet view, I see the seed device and subnet icons. In the hop view, if I choose subnet
view, only the seed device is displayed. However if I go to the network view and
choose subnet view, I see the seed device and subnet icons.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44090
APAR : IV44161
-----------------------
Abstract: CISCOSWITCHSNMP AGENT CAN FAIL TO DISCOVER CONNECTIONS WHEN
MULTIPLE VLANS ARE CONFIGURED
Description: In some cases the CiscoSwitchSnmp agent can fail to retrieve
connections when the device is configured with multiple VLAN. Missing link between devices which don't have CDP enabled.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44161
APAR : IV44176
-----------------------
Abstract: MISSING EXTRAINFO DATA FROM DETAILS COLLECTOR
Description: All collector data which added by customer via extraInfo.cfg is missing in the TIP.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44176
APAR : IV44266
-----------------------
Abstract: NCP_TRAPMUX NOT FRAGMENTING SNMP PACKETS FOR LARGE MESSAGES
Description: SNMP packet is too
large (i.e. > 1500bytes).
This seems related to IV00342.
When ncp_trapmux receives a trap exceeding 1500 bytes, it
can result in the error message 'System Error sending packet.
Message too long' when it tries to forward the trap to a remote sink Host.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44266
APAR : IV44471
-----------------------
Abstract: SAM COLLECTOR FAILED TO DISCOVER VPN INTERFACES
Description: Missing interfaces in discovery, due to absence of
<displayedName> tag in SOAP response for interfaces data
This results the collector to fail.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44471
APAR : IV45047
-----------------------
Abstract: AMS EXTRAINFO->M_IFOPERSTATUS UNKNOWN
Description: Device's m_IfOperStatus always show 4(Unknown) after downloaded by IDM
5529 collector.Fix collector to download data correctly.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45047
APAR : IV45185
-----------------------
Abstract: PERFORMANCE REPORTS DO NOT HONOR THE HOSTNAME OR IP
ADDRESS FILTER
Description: When attempting to filter results for Performance reports (for
example "Bandwidth Utilization" or "Device Availability
Summarization", the report does not honor the filter but
instead provides output for every device regardless of the
filter content.
Filtering in performance reports on ip address fails to
display reports correctly. Instead it returns ALL ip addresses.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45185
APAR : IV45258
-----------------------
Abstract: AFTER APPLYING ITNM V3.9 FIX PACK 3: TAGMANAEDENTITIES.STCH DOES
NOT HONOR ENTITYTYPE=2 FILTER RESULTING IN UNMANAGED ENTITIES
Description: This APAR is created as AE/MDV APAR with "MDVRGRS" class.
MDVPARTL 3.9.0-TIV-ITNMIP-FP0003
TagManagedEntities.stch does not honor EntityType=2 filter when
the condition is based on EntityOID. This was working correctly
in earlier builds and is broken on FP3.
After the enhancement of OQL optimization made in FP3, an
OQL query involving a mix of indexed and unindexed queries
on the same table AND'd together could in some cases result
in the wrong data being returned.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45258
APAR : IV45467
-----------------------
Abstract: TOPOVIZ CREATES ILLEGAL SQL QUERY WHEN USING ADVANCED SQL FILTER
Description: Topoviz creates illegal sql query when using advanced sql filter.
When creating a network view with an advanced sql filter in topoviz the
backend creates an illegal sql query which doesn't work in mysql.
Caused by: java.lang.RuntimeException: Error executing query:xxxx. The query used in
network filtered view was prefixed by
"t.", to avoid column name conflicts, but didn't work for all cases.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45467
APAR : IV45561
-----------------------
Abstract: DOCUMENTATION LACKING FOR COLLECTOR BASED DISCOVERIES
Description: When attempting to configure collector based discoveries there
is not enough information provided in the info center nor in
the configuration files to determine the what changes to make
to achieve desired results. This APAR was created in order to
provide a more detailed level of documentation for use when
using all collector based discoveries.
Added Timeout property. Added more detailed information on
the data retrieved by GetEntitites and GetONT.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45561
APAR : IV45637
-----------------------
Abstract: STRUCTURE BROWSER DOES NOT SEARCH THROUGH ALL ELEMENTS OF THE
DEVICE STRUCTURE TREE
Description: The user is unable to find a node in the Device Structure Tree,
which in fact does have a match to the specified search phrase.
The reason is that the Device Structure Tree Search facility
uses a static SQL query to search for predefined entity
attributes of a specified entity Id, only for the following
entity types: [interface, ip endpoint]. With the addition of new
entity types (VLAN for example), this SQL query became obsolete
and therefore not able to find everything which could be in the
Device Structure Tree.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45637
APAR : IV45870
-----------------------
Abstract: AVAYA PHYSICAL INVENTORY AGENT CORE DUMP.
Description: The agent fails to complete during discovery, exits
unexpectedly and a core file is generated.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV45870
APAR : IV45912
-----------------------
Abstract : ADDJUNIPERENTITYCONTAINMENT STITCHER ISSUE
Description: Some interfaces of Juniper were not in the correct containment after enabling JuniperBoxAnatomy agent.
In AddJuniperEntityContainment stitcher, some interfaces would missed out while
resolving to the correct containment. The oql statement should use m_BaseName instead
of m_UniqueAddress while retrieving all the interfaces entity from
workingEntities.finalEntity table. The stitcher code includes changes to include the
jnxContentsPartNo and jnxContentsRevision attributes into the entity.
https://www.ibm.com/support/docview.wss?uid=swg1IV45912
APAR : IV46243
-----------------------
Abstract: When Interface alarms incorrectly associated to Chassis, they
suppress other unrelated alarms on chassis
Description: Alarms for interfaces that could not be found in the topology
(either because the interface was removed from the topology to
improve performance or because of other issue with syslog
interface alarms -IV47678 ) were suppressing other unrelated
alarms on the chassis and down stream network. This would
happen because the alarms were being updated to set the
NmosEntityId to the EntityId of the chassis. The
LookupIfEntry.stch prevents the alarm being treated as a
chassis alarm on it's first occurrence but subsequent
occurrences are treated by RCA as at the level of the chassis
because of the value of the NmosEntityId.
An event raised against an interface which is not found will become root cause,
suppressing other events on the containing chassis, if it raised more than once.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV46243
APAR : IV46301
-----------------------
Abstract: CHANGE/IMPROVEMENT OF ITNM START/STOP/STATUS SCRIPTS
Description: Currently the behavior of the itnm stop/start/status is
unsatisfactory. The itnm_status script tries to show the status of all
processes running under nco_pad.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV46301
APAR : IV46436
-----------------------
Abstract: ITNM TOOLS SKIP PROCESSING OF THE ENTITYID LIST LIST WHEN A
COOKIE IS USED
Description: The 'target' parameter contains the parameter name instead of
the entity Id. Using a cookie in the URL Tool definition was breaking the
value for parameter 'target' in the resulted URL.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV46436
APAR : IV46560
-----------------------
Abstract: ITNM GATEWAY (NCP_G_EVENT) CANNOT HONOUR COMMON GATEWAY
PROPERTIES.
Description: There is no capability in the Gateway for the user to
configure common Gateway properties such as IPC.TIMEOUT
ITNM gateway needed to support Ipc.Timeout property (common
property) in order to drop the connection to the Primary ObjectServer
quickly if no activity was detected. Otherwise it would wait 60 seconds
before timing out (default value) and then would retry 2 more times before
failing over.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV46560
APAR : IV46675
-----------------------
Abstract: DLA BOOK HAS A ROUTER CLASS WITH A HARD CODED NAME OF "ROUTER".
Description: DLA book has a router class with a hard coded name of "router".
The Classes Router and Bridge have the instance name hard
coded as Router and Bridge
http://www-01.ibm.com/support/docview.wss?uid=swg1IV46675
APAR : IV46734
-----------------------
Abstract: DYNAMIC DISTINCT VIEWS CHANGE THEIR PARENT-CHILD HIERARCHY IN THE NETWORK VIEW TREE
Description: When the filter for Dynamic Distinct view is created by the user, he may or
may not list the table fields in alphabetic order.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV46734
APAR : IV47106
-----------------------
Abstract: THE ITNM DLA DO NOT EXPORT ENTITY DETAILS THAT HAVE CUSTOMER
MEANINGFUL INFORMATION
Description: The ITNM DLA do not export entity details that have customer
meaningful information. ITNM DLA was updated to export the
entity detail as an extended attribute of the class when the new
property is defined as ncp.dla.entity.details=true..
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47106
APAR : IV47312
-----------------------
Abstract: NCP_DH_ARP CORE BAD PACKET RECEIVED WITH MISSING FIELD.
Description: Arp helper restarts, or essentially cores.
As we got the bad packet to ARP helper, there isn't any field
of RIV_REQUEST -"RivAgentDataRequest".
This caused the Fatal error in DAPRCheckHelperName.
Multiple occurrences of the same client Id detected.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47312
APAR : IV47318
-----------------------
Abstract : ASSOCADDRESS AGENT ISSUE
Description : ITNM assigned wrong IP address into interface, where the wrong IP address is
a broadcast address ending with 255. In the new ipAddressTable, check the value of
ipAddressType. If ipAddressType value is broadcast(3), discard the entry and do not assign
the broadcast address into the interface record. This fix affects the following agents:
AssocAddress, Interface and InetRouting.
https://www.ibm.com/support/docview.wss?uid=swg1IV47318
APAR : IV47598
-----------------------
Abstract : INTERFACE AGENT FAILS TO CHECK VALIDITY OF IPADDRESSPREFIX
Description : Subnet IP address for certain devices are not presented correctly.
Modified Interface agent to check the validity of ipAddressPrefix response. If the response
is not valid, agent should gather subnet information from old IPTable.
https://www.ibm.com/support/docview.wss?uid=swg1IV47598
APAR : IV47678
-----------------------
Abstract: GATEWAY INTERFACE LOOKUPS SHOULD ACCEPT PLAIN IFNAME IN
LOCAL PRI OBJ IF NO MATCH IN THE FORMAT "IFENTRY.<IFNAME>"
Description: Syslog interface alarms were not being matched to interfaces in
the topology. ExtractIfString.stch assumes that in the ifDescr
value in the LocalPriObj or LocalRootObj were prefixed with a
"ifEntry." string as is the convention for the ifIndex in
interface traps. The problem is that these are not currently matched to the
interface by the gateway.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47678
APAR : IV47759
-----------------------
Abstract: CHUNK3 AND CHUNK4 ERRORS CREATED BY CONTAIN RESOLVABLE ENTITIES
STITCHER
Description: The variables chunk3/chunk4 are deleted within a loop causing
two errors each time through the loop:
2013-07-20T08:25:17: Warning: W-RIV-002-139: [1543t]xxxxxxxxx.cc(212)
The following stitcher rule failed to complete correctly.
This causes thousands of error messages each time the topology
is stitched.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47759
APAR : IV47816
-----------------------
Abstract: RCAPATHTOOL RESULTS DIFFER FROM ACTUAL CONNECTIVITY(LAYER2) EVEN
THOUGH RCA END RESULTS ARE ACCCURATE
Description: RCA path tool(ncp_pathtool) supposed to use the shortest path,
instead it uses some random path which is inaccurate. ncp_g_event pathtool
shows too many nodes that are unrelated to the A-Z path.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47816
APAR : IV47867
-----------------------
Abstract: NETNUMBER AND IPNUMBER IN NCIM.IPENDPOINT INCORRECTLY CALCULATED
Description: The NETNUMBER and IPNUMBER are incorrectly calculated
for IPv6 addresses. Some translations of IPv6 addresses to number form failed on
little endian systems because ntohl() was used with 64-bit
values (it only supports 32-bit).
User running on, say, linux on intel x86 (little endian)
encountered the issue while big endian systems (e.g Solaris
on SPARC, or AIX on PowerPC) wouldn't hit the issue.
The end result was that the IPNUMBER and NETNUMBER values in
NCIM's ipEndPoint table could be wrong.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47867
APAR : IV47900
-----------------------
Abstract: REPORTS SHOW GARBLED POLICY NAME FOR OUTPUT IN RUSSIAN ENV
Description: (Windows Only) The report output for Bandwidth Utilization Drill down
and Generic Trend Analysis Drill down Report (possibly others)
will show garbled characters for the policy name. The Performance Drill down Cognos
Reports shows the policy name garbel.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47900
APAR : IV48135
-----------------------
Abstract: NETWORK VIEW VISUALISATION ISSUES
Description: MPLS and subnet views not displayed; IP Filtered Views membership
inconsistent for end nodes included/excluded; hop views and network views do not agree
on links displayed for layer 3 connectivity
http://www-01.ibm.com/support/docview.wss?uid=swg1IV48135
APAR : IV48866
-----------------------
Abstract: THE ALCATEL5620SAMSOAP COLLECTOR PRODUCES NCP_DISCO ERRORS WHEN
PROCESSING THE ALU SGW IPV6 ADDRESSES.
Description: The issue is that we are discovering IPv6 addresses from the
SAM but the Collector framework assumes IPv4 and sets the
protocol to IPv4. Collector framework doesn't support IPv6 (it assumed IPv4)
and the EMS is providing IPv6 addresses.
As a result the IPv6 addresses end up in the Disco tables
with the incorrect protocol set. This leads to warning such as;
Warning: A generic error has occurred found in file
CDiscoStitcherIsInScope.cc at line 155 - IP address: xxx is
not valid
http://www-01.ibm.com/support/docview.wss?uid=swg1IV48866
APAR : IV49264
-----------------------
Abstract: CISCO WEBTOOL SPECIFIED OVER SSH V2 EXCEED THE INITIAL WINDOW SIZE AND FAILED
Description: When creating a cisco webtool (or modify an existing one) that
should execute many commands, exceeding a buffer limit ,
it exceeds the initial window size and failed with
message channel window size adjustment.
This happens only if connect by SSH V2. When connecting by
telnet or SSH V1 it works fine.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV49264
APAR : IV49805
-----------------------
Abstract: DISCO.FILTER CUSTOM TAGS FAILS TO TAG IP ADDRESSES.
Description: Custom tags fails with only garbage in the log file.
disco.filter CustomTags failed to tag the specified
m_CustomTags for the IP address due to the invalid syntax in
AddCustomTags.stch
http://www-01.ibm.com/support/docview.wss?uid=swg1IV49805
APAR : IV49860
-----------------------
Abstract: THE ITNM DATABASE SCRIPT (ORACLE) GRANTS WIDER PRIVILEGES THAN IT NEEDS.
Description: The ITNM database script (Oracle) grants wider privileges than
it needs.The proposed change is to minimise those privileges in database creation scripts.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV49860
APAR : IV49968
-----------------------
Abstract: CIRCULAR RCA
Description: At times, Circular RCA observed without any Root Cause based on
the sequence the events come in.
Circular suppression involving either 3 or 4 entities. e.g.
A suppressing B suppressing C suppressing D suppressing A.
One of the suppression types is always connected
suppression.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV49968
APAR : IV50276
-----------------------
Abstract: TIP RUNS OUT OF MEMORY WHEN USER OPENS TOPOVIZ WITH A LARGE SAVE
VIEW
Description: TIP runs out of memory because we allocate memory for the entire
uncompressed map before sending it to the client. During loading the Network View graph consumes too much memory causing OOM.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV50276
APAR : IV50278
-----------------------
Abstract: PATH TOOL FAILS WHEN USING A NON-DEFAULT TIP PORT
Description: If trying to add a path to trace via the gui, on a TIP using a
non-default port the following error message appears in the GUI:
"Error Tracing Path An error occurred while running the PathTrace Tool.
Check ncp_topoviz log file for a detailed error message or
press View Path Trace Details to view the PATH Tool output. ..."
PATH creation via the GUI failed, if TIP is configured to use non-default port.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV50278
APAR : IV50295
-----------------------
Abstract: VLAN DATA WHERE VLANID GREATER THAN 999 FAILS TO BE DOWNLOADED
Description: Updated the agent to be able to receive and process vlan id greater than 999
http://www-01.ibm.com/support/docview.wss?uid=swg1IV50295
APAR : IV50470
-----------------------
Abstract : NETSCREENINTERFACE AGENT CAUSES DISCOVERY TO HANG WHEN A NSIFNAME CONTAINS COLON(:) - E.G. ETHERNET1/2.1:1
Description : Due to the present of both logical unit identifier and channel in the interface
name. e.g. ethernet0/1.1:1 when deciding the upward connection.
https://www.ibm.com/support/docview.wss?uid=swg1IV50470
APAR : IV50718
-----------------------
Abstract: PERFORMANCE ISSUES WITH POLLER WHEN POLLING HIGH NUMBER OF
ENTITIES
Description: When poller is configured to do ICMP polling of around 10k
entities, poller falls behind with multiple messages in
ncp_poller.SnmpPoller.<DOMAIN>.trace: <snip>
2013-10-02 11:12:43 SEVERE xxxxxx.cc(417): About to submit
batch, but there aren't any threads available..
At this point - poller process memory size starts to
increase and eventually it fails with Out-of-memory error.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV50718
APAR : IV50721
-----------------------
Abstract: IN RCA, MAXAGEDIFFERENCE BETWEEN TWO EVENTS SHOULD BE CALCULATED
USING FIRSTOCCURRENCE ONLY, NOT LASTOCCURRENCE TIMESTAMP.
Description: In RCA, the MaxAgeDifference (this attribute is listed in
RCASchema.cfg) between two events should be calculated using
FirstOccurrence timestamps only, not LastOccurrence timestamps.
Events that first occur an hour apart say but keep on failing still get correlated even
though their FirsOccurrence timestamps are greater than 15 minutes apart.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV50701
APAR : IV50786
-----------------------
Abstract: NCP_POLLER STOPS WORKING AFTER NCIM RESTARTS
Description: ncp_poller memory consumption is increasing indefinitely until
it stops working. This can be seen in the ncp_poller debug logs from the memory
usage messages: Debug: D-MOM-001-051: [1t] Generating heartbeat: memory usage:
110731264 bytes...When database was disconnected the Poller would not always
reconnect
http://www-01.ibm.com/support/docview.wss?uid=swg1IV50786
APAR : IV51240
-----------------------
Abstract: ENTITYFILTER IN MODELNCIMDB.CFG ALLOW FOR DUPLICATE MATCHES.
Description: During Topology updates the following errors are
observed in the ncp_model.<domain>.log
Warning: W-RIV-002-206: [4117887888t] xxxxxxx.cc(xxx) A
database 'execute' operation has failed : SQLRETURN = -1
xxxxxxx.xx.cc line xxx : [Informix][Informix ODBC
Driver][Informix]Unique constraint (xxxx.xxxxxxxxx_pk)violated....
Warning: W-RIV-002-128: [4117887888t] xxxxxxxx.cc(xxxx)
xxxxxxxxxxx::RecordToExternalDb: Failed to update
Cause: The default dbModel.entityMap.EntityFilter values in
ModelNcimDb.cfg file allow for duplicate matching. Filters in
this file should not match more than one record.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV51240
APAR : IV51576
-----------------------
Abstract : IFOPERSTATUS OF INTERFACES IS NOT MERGED INTO FINAL TOPOLOGY FOR NETSCREEN DEVICES
Description : ifOperStatus is not updated onto Interface for NetScreen device.
However the data is available at Chassis level for all Interfaces. NetScreenInterface agent is
modified to retrieve ifOperStatus from IF MIB, and update it to respective Interface.
https://www.ibm.com/support/docview.wss?uid=swg1IV51576
APAR : IV52022
-----------------------
Abstract: MODEL TO NCIM BATCH TRANSFER TIME SPIKES OCASIONALLY
Description: Model to NCIM batch transfer time spikes ocasionally to very high values
https://www.ibm.com/support/docview.wss?uid=swg1IV52022
APAR : IV52877
-----------------------
Abstract: DEADLOCK DETECTION OCCURS WHILE CACHING NETWORK VIEWS(MYSQL
ONLY)
Description: Deadlock detections noticed in following scenario:
While loading the networkView Tree for the very first time, the
Views in the tree are being registered for events. Registering
views for the events causes to cache the Views. During caching
process,deadlock detections are noticed.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV52877
APAR : IV53347
-----------------------
Abstract: INCOMPLETE ENTITY AGENT DATA CAN CAUSE A CORE DUMP IN THE AGENT AND IMPACT ON THE COMPLETION OF DISCOVERY.
Description : Core dump happened when enable Entity Agent in discovery. It's triggered by
incomplete data downloaded being downloaded which later causes core dump when
Entity Agent try to process it. Core message will be similar to below:
0x00227bec in xxxxxxx::ResolveInterfaces (this=0x95d54a0, neRecord=0xf71004e0,
neMedData=0xf6e00488, entityDataByPhysIndex=@0x93de0b4) at xxxxxxxx.cc:1279
https://www.ibm.com/support/docview.wss?uid=swg1IV53347
APAR : IV53975
-----------------------
Title : NETWORK MANAGER IP EDITION 2013 INTEGRATIONS R1 (3.9)
Problem : Support added for the following:
(1) IOT Certified Collector discovery support for Alcatel-Lucent SAM 5620 Release 11 using FindToFile method.
(2) IOT Certified Collector discovery support for Alcatel-Lucent IDM 5529 Release 9.2.30
Access Domain using getInventoryIterator method.
(3) Juniper QFabric discovery agent for Juniper physical inventory discovery.
(4) Discovery support for ZTE M6000, T1200 and T600 Physical Inventory.
(5) VLAN discovery support ExtremeSwitch version 12.
(6) HTTPS support for perl Collector Framework and Alcatel5620SamSoap,
Alcatel5620SamSoapFileToFile and Alcatel5529IdmSoap collector.
https://www.ibm.com/support/docview.wss?uid=swg1IV53975
APAR : IV54305
-------------
Abstract: COLLECTORINVENTORY AGENT CRASHED
Description: The CollectorInventory Agent could crash due to complications caused by an
entity existing twice (it tries to delete the data twice).
Two Agents are potentially vulnerable to this bug:CollectorInventory and CollectorVpn.
Prior to the crash it would output the following warning;
http://www-01.ibm.com/support/docview.wss?uid=swg1IV54305
APAR : IV54522
-----------------------
Abstract: INAPPROPRIATE IOCTL CALL CAUSING KERNEL LOG ERRORS (APAR=IV54522)
Description: Thousands of following errors were logged to /var/log/messages
during discovery by ncp_d_helpserv, ncp_disco, ncp_df_*
ncp_agent processes and also by ncp_virtualdomain irrespective of the discovery status.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV54522
APAR : IV54682
-----------------------
Abstract: MISSING STACKED ENTITY INFORMATION ON CISCO DEVICE
Description:Chassis information is missing from containment when Cisco's
device is configured as Stack Type
http://www-01.ibm.com/support/docview.wss?uid=swg1IV54682
APAR : IV55034
-----------------------
Abstract: UPDATE THE VERSION OF GSKIT USED BY ITNM 3.9
Description: ITNM version 3.9 Fp4 upgraded with GSKIT 8.0.14.33.
APAR : IV55230
-----------------------
Abstact: POLLER SHOULD NOT ATTEMPT TO RECREATE A MONITOR ASSOCIATED WITH
AN UPDATED ENTITY WHOSE IP ADDRESS CHANGED TO NULL
Description: Poller should not attempt to recreate a monitor associated with
an updated entity whose IP address changed to NULL. It has been
shown to be possible to receive a managed status change for an
entity with a new IP address which is NULL resulting in the
poller coring while trying to recreate the snmp target. We
should intercept this immediately upon detecting it, ignore the
update but log a message.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV545230
APAR : IV55465
-----------------------
Abstract: ITNM 3.9 NETWORK DEVICE CONFIGURATION ERRORS DISPLAYS DATA FROM OTHER DOMAINS
Description: When running the Network Device Configuration Errors report in
an environment where there are multiple domains, the section "Connected Devices with Duplex Mismatches"
will combine data from any domain stored in the NCIM database.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV55465
APAR : IV55657
-----------------------
Abstract: EVENT FILTERED VIEWS ARE MISSING THE OPERAND WHEN MORE THAN ONE FILTER IS SPECIFIED
Description: Using multiple filters produces inconsistent results for Maximum Severity.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV55657
APAR : IV56487
-------------
Title : ALCATEL 5529 COLLECTOR TIMEOUT ERROR (APAR=IV56487)
Problem : The Alcatel5529IdmSoapCollector fails with error:
500 Server closed connection without sending any data back at
/opt/IBM/tivoli/netcool/precision/collectors/perlCollectors/Alcatel5529IdmSoap/Alcatel55
29IdmSoapCollector.pm line 225
Due to this timeout, the collector exits and discard all other discovered devices.
http://www.ibm.com/support/docview.wss?uid=swg1IV56487
APAR: IV56672
-------------
Abstract: CREATETRUNKCONNECTIONS STITCHER COULD GENERATE DISCO CORE WHEN DEALING WITH CORRUPTED DATA
Description:Due to failed SNMP or wrong device configuration, the NortelSwitch.retuns table can generate Trunked Vlan information as a 0 lenght list.
http://www.ibm.com/support/docview.wss?uid=swg1IV56672
APAR : IV56717
-----------------------
Abstract: ADDED AOC DEVICE CLASSIFICATIONS IN ITNM FOR THE ARISTA MANUFACTURE AND A SUB-CLASS FOR THE ARISTA VEOS.
Problem: Added new AOC device classifications in ITNM for the Arista manufacture and a
sub-class for the Arista vEOS. Support for those devices once discovered with standard
discovery agents turned on.
http://www.ibm.com/support/docview.wss?uid=swg1IV56717
APAR : IV59327
---------------------
Abstract: DB2 PROVIDES A NUMBER OF STRATEGIES FOR IMPROVING THE AVAILABILITY OF YOUR DATABASE SOLUTION, INCLUDING A FEATURE DB2 (HADR)
Problem: Network Manager allows you to configure the NCIM topology database for high availability,minimizing the impact of computer or network failure.
http://www.ibm.com/support/docview.wss?uid=swg1IV59327
============================================================================
IBM Tivoli Network Manager V3.9 must be installed before applying this
Fix Pack. Fix Pack 4 can be install over original 3.9 GA (3.9.0.32), 3.9 Refresh (3.9.0.68) or any other 3.9 Fix Pack.
Ensure that there is approximately 1 GB of free space on the drive on which the product was installed.
Windows 2008 imposes a limit of 260 characters for the full name (including path) of a file.
Network Manager 3.9 Fix Pack 2 and later fix packs already have some very long directory names
because the fix pack contains updates from many components such as WebSphere, TIP, TCR,
which by themselves are up to 221 characters in length, including separators. Therefore Windows
users are advised to select a location for the compressed Network Manager 3.9 Fix Pack image
on their machine so that when extracted, the resulting file names are less than 260 characters.
For example, C:\Build will work as a location for the fix pack image, but
C:\Users\Administrator\Desktop\Test will not.
Note: When using the Windows command line, preface and suffix environment
variables with the percentage sign %, and replace each forward slash (/)
with a backslash (\) in directory paths.
For example, on Windows systems, $NCHOME is %NCHOME%.
Full details on installation prerequisite for this fixpack can be found in the
3.9.0_INSTALL_FP0004 file.
Full details on installation prerequisites and installation steps for this fixpack can be found in the 3.9.0_INSTALL_FP0004 file, which is downloadable from the link below..
If upgrading an existing IBM Tivoli Network Manager (ITNM) 3.9 installation that is using Tivoli Integrated Portal (TIP) version 2.1 to use TIP version 2.2, you will need the TIP FIT package. The TIP FIT package contains a TIP signature file used with TIP 2.2 Fix Packs and Feature Pack. Additional fix packs for TIP 2.2 can be applied after TIP 2.2.0.1 (Feature Pack), such as TIP 2.2.0.13. Each fix pack of TIP 2.2 (such as TIP 2.2.0.13) will have a separate TIP FIT package / signature file associated with it.
To obtain the TIP signature files, download them from Fix Central -->
http://www-933.ibm.com/support/fixcentral/swg/selectFixes?parent=ibm~Tivoli&product=ibm/Tivoli/Tivoli+Integrated+Portal&release=All&platform=All&function=all
Note from the TIP support team: the FIT packaging is bit different from TIP 2.2.0.1 to TIP 2.2.0.13. In TIP 2.2.0.13, FIT package you will not see any "input" folder and the signature file will be part of FIT.jar
Please use the same user id that you used to install the product/fix pack to extract these and then run the fix pack installer.
URL | LANGUAGE | SIZE(Bytes) |
---|---|---|
3.9.0_INSTALL_FP0004 | English | 66410 |
3.9.0_README_FP0004 | English | 80800 |
3.9.0_INSTALL_NLS_FP0004 | Language Independent | 239500 |
3.9.0_README_NLS_FP0004 | Language Independent | 179300 |
Download | RELEASE DATE | LANGUAGE | SIZE(Bytes) | Download Options |
---|---|---|---|---|
3.9.0-TIV-ITNMIP-AIX-FP0004 | 17 Apr 14 | Language Independent | 1361609440 | HTTP |
3.9.0-TIV-ITNMIP-Linux-FP0004 | 17 Apr 14 | Language Independent | 1118954929 | HTTP |
3.9.0-TIV-ITNMIP-Solaris-FP0004 | 17 Apr 14 | Language Independent | 1226380525 | HTTP |
3.9.0-TIV-ITNMIP-Windows-FP0004 | 17 Apr 14 | Language Independent | 1118961594 | HTTP |
3.9.0-TIV-ITNMIP-zLinux-FP0004 | 17 Apr 14 | Language Independent | 1345823499 | HTTP |
Contacting IBM Support
Please use the IBM Tivoli Support website:
http://www-01.ibm.com/software/support/exchangeinfo.html
Problems (APARS) fixed
IV16886, IV17929, IV20912, IV22660, IV22788, IV23287, IV25953, IV26760, IV27702, IV28121, IV29828, IV30425, IV31296, IV31587, IV31984, IV32386, IV32747, IV33079, IV33095, IV33114, IV33118, IV33128, IV33250, IV33478, IV33533, IV33578, IV33996, IV34108, IV34113, IV35501, IV35661, IV35842, IV36091, IV36109, IV36368, IV36581, IV36679, IV36728, IV36856, IV37074, IV37322, IV37587, IV37779, IV38084, IV38239, IV38395, IV38462, IV38610, IV38617, IV38618, IV38744, IV38974, IV39072, IV39195, IV39203, IV39428, IV39551, IV39822, IV39998, IV40185, IV40211, IV40479, IV40995, IV41267, IV42617, IV42667, IV42743, IV42747, IV43090, IV43140, IV43184, IV43870, IV43944, IV44090, IV44161, IV44176, IV44266, IV44471, IV45047, IV45185, IV45258, IV45467, IV45561, IV45637, IV45870, IV45912, IV46243, IV46301, IV46436, IV46560, IV46675, IV46734, IV47106, IV47312, IV47318, IV47598, IV47678, IV47759, IV47816, IV47867, IV47900, IV48135, IV48866, IV49264, IV49805, IV49860, IV49968, IV50276, IV50278, IV50295, IV50470, IV50718, IV50721, IV50786, IV51240, IV51576, IV52022, IV52877, IV53347, IV53975, IV54305, IV54522, IV54682, IV55034, IV55465, IV55657, IV56487, IV56672, IV56717, IV38462, IV42667, IV46301, IV53975, IZ81036, IZ84399, IZ85441, IZ85921, IZ86011, IZ86201, IZ87271, IZ87567, IZ88605, IZ89794, IZ90247, IZ91113, IZ92126, IZ92339, IZ92490, IZ92509, IZ94332, IZ94405, IZ94550, IZ94642, IZ94749, IZ94826, IZ95110, IZ95507, IZ95608, IZ95646, IZ96015, IZ96016, IZ96220, IZ96242, IZ96285, IZ96537, IZ96931, IZ96937, IZ97314, IZ97409, IZ97548, IZ97974, IZ98083, IZ98663, IZ98723, IZ98726, IZ99012, IZ99308, IZ99474, IZ99855, IV00140, IV00342, IV00366, IV00411, IV00446, IV00602, IV00672, IV00818, IV00848, IV00908, IV00926, IV01020, IV01100, IV01170, IV01535, IV01549, IV01587, IV01592, IV01614, IV01634, IV01669, IV01706, IV02082, IV02127, IV02229, IV02407, IV02671, IV02808, IV02909, IV02995, IV03085, IV03086, IV03128, IV03133, IV03378, IV03413, IV03486, IV03631, IV03642, IV03865, IV03968, IV04074, IV04075, IV04531, IV04718, IV05797, IV06195, IV06240, IV06272, IV06321, IV06337, IV06455, IV06477, IV06712, IV06743, IV06779, IV06791, IV07103, IV07104, IV07249, IV07631, IV07647, IV07692, IV07753, IV07856, IV07982, IV07909, IV08015, IV08018, IV08027, IV08192, IV08381, IV08412, IV08604, IV08768, IV08981, IV09035, IV09209, IV09214, IV09221, IV09223, IV09228, IV09229, IV09231, IV09255, IV09256, IV09257, IV09258, IV09454, IV09898, IV10323, IV11080, IV11088, IV11270, IV11271, IV11558, IV11669, IV11761, IV11827, IV11863, IV12280, IV12461, IV13720, IV15328, IV15330, IV15334, IV15377 , IZ93148, IV04119, IV05220, IV06737, IV10323, IV10934, IV12927, IV14221, IV16149, IV16616, IV16932, IV17575, IV18992, IV19652, IV19896, IV19902, IV20128, IV20184, IV20521, IV20645, IV20889, IV20914, IV21263, IV22071, IV22259, IV22788, IV22799, IV22823, IV22901, IV22933, IV23003, IV23058, IV23136, IV23424, IV23863, IV24206, IV24388, IV24718, IV24844, IV24928, IV24939, IV25131, IV25264, IV25446, IV25833, IV25842, IV25872, IV25978, IV26274, IV26368, IV26372, IV26406, IV26410, IV26591, IV26605, IV26715, IV26837, IV26842, IV27231, IV27341, IV27515, IV27599, IV27616, IV27886, IV27953, IV28583, IV28595, IV28613, IV28640, IV28694, IV29152, IV29544, IV29897, IV29988, IV30387, IV30422, IV30443, IV30445, IV30508, IV30619, IV30624, IV30706, IV30730, IV30775, IV30811, IV30848, IV30850, IV30854, IV30911, IV31166, IV31168, IV31221, IV31293, IV31294, IV31348, IV31549, IV31562, IV31581, IV31635, IV31637, IV32321, IV32323, IV32342, IV32418, IV32431, IV32842, IV33100, IV33113, IV33618, IV35487, IV36447, IV07908, IV08858, IV11080, IV11558, IV11724, IV12417, IV12850, IV12852, IV13225, IV13306, IV13415, IV13821, IV13837, IV14984, IV15724, IV15474, IV15667, IV15884, IV16076, IV16501, IV16617, IV16972, IVI7003, IV17407, IV17974, IV18035, IV18079, IV18264, IV19065, IV19168, IV19196, IV19213, IV19228, IV19607, IV19690, IV19726, IV19812, IV19825, IV19909, IV20134, IV20201, IV20360, IV20529, IV20642, IV20916, IV21442, IV21443, IV21587, IV21588, IV21589, IV21663, IV21789, IV21935, IV21970, IV21972, IV21975, IV21990, IV22011, IV22243, IV22553, IV22562, IV22899, IV22900, IV22902, IV22903, IV22994, IV22997, IV22998, IV23003, IV23008, IV23011, IV23055, IV23278, IV24089, IV24128, IV24247, IV24249, IV24421, IV24617, IV24795, IV24945, IV25254, IV25255, IV25256, IV23278, IZ88972
IBM Tivoli Network Manager IP 3.9.0 Fix Pack 3 was released on February 14, 2013. This Fix Pack contains known issues and has been superceded by IBM Tivoli Network Manager IP 3.9.0 Fix Pack 5. We highly recommend that all customers running version 3.9 of ITNM DO NOT install this fixpack and instead plan to deploy IBM Tivoli Network Manager IP 3.9.0 Fix Pack 5 or begin plans to upgrade to ITNM version 4.1 or later. Contact us today to receive information about how we can help you upgrade your monitoring environment.
*******************************************************************
* A change introduced by 3.9.0-TIV-ITNMIP-FP0003 might negatively
* affect existing product function.
*
* Please refer to APAR(s) IV37584, IV38744, IV39998 and IV45258 for a description of the
* problem(s) and corrective action(s).
*
*APAR:IV37584 APAR:IV38744 APAR:IV39998 APAR:IV45258
*
*Evaluate these APARs for the potential impact in your environment.
*******************************************************************
Known problems with V3.9.0 Fix Pack 3
=======================================================================
Known problems are documented in the form of individual Technotes in the Software Support
knowledge base. Go to the following link to perform an advanced search of the knowledge base:
http://www-01.ibm.com/software/sysmgmt/products/support/IBMTivoliNetworkManagerIPEdition.html
Go to the following link to retrieve all technotes for version 3.9 of Network Manager:
http://www-01.ibm.com/support/search.wss?tc=SSSHRK&q=technote+3.9
Installing the V3.9.0 Fix Pack 3 ====================================================================== IMPORTANT: This fix pack provides performance improvements for topology visualization and adaptive polling. The improvements require a database schema upgrade for Fix Pack 3. The schema upgrade does not modify the functional behavior of Network Manager, and the schema changes are compatible with Network Manager 3.9 or earlier 3.9 Fix Packs. You will need to apply the schema upgrade before installing Fix Pack 3 Full details on how to upgrade schema and install this fixpack can be found in the 3.9.0_INSTALL_FP0003 file which is downloadable below. . Summary of fixes in V3.9.0 Fix Pack 3 ====================================================================== For a description of the APAR, please use the link provided or review the Readme file APAR: IZ93148 ----------------------- Title:SINGLE QUOTES IN LDAP GROUP NAMES CAUSE AUTHENTICATION ERRORS IN NETWORK VIEWS Link: https://www.ibm.com/support/docview.wss?uid=swg1IZ93148 APAR: IV04119 ----------------------- Title:ITNMEXPORTNETWORKVIEWS.PL SCRIPT AND CUSTOM DYNAMIC DOMAINS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV04119 APAR: IV05220 ------------- Title: ITNM3.9 SNMP_WALK.PL FAILS TO WALK LARGE TREES Link: https://www.ibm.com/support/docview.wss?uid=swg1IV05220 APAR: IV06737 ----------------------- Title:ENTITIES WITH SYSCONTACT OR SYSLOCATION WITH VALUE 'CC' DO NOT GET SENT OR GET TRANSLATED INTO ANSI CODE INTO NCIM. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV06737 APAR: IV10323 ----------------------- Title:THE ITNM_CONTROL_FUNCTIONS.SH SCRIPT NOT COONFIGURED TO THE CORRECT PATH TO ITNM.CFG. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV10323 APAR: IV10934 ----------------------- Title:DLA NEEDS UPDATE TO INCLUDE RELATIONSHIPS TO TOPLEVELS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV10934 APAR: IV12927 ----------------------- Title:REDUCING VERBOSITY OF NCP_POLLER.SNMPPOLLER.<DOMAIN>.TRACE CONTAINS LOT OF REPEATATIVE MESSAGES CAUSES LOGFILE TO GROW HUGE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV12927 APAR: IV14221 ------------------------ Title: THE DOMAIN_DROP.PL SCRIPT IS SUPPOSED TO INCREMENTALLY DELETE ENTITIES FROM A DOMAIN. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV14221 APAR: IV16149 ----------------------- Title: Wrong subnet and netmask for Chassis IpAddress Link: https://www.ibm.com/support/docview.wss?uid=swg1IV16149 APAR: IV16616 ----------------------- Title: DATA IMPORT OF VIEWS IS FAILING BECAUSE OF INVALID ENTITYNAME(S) IN THE NCIM.ENTITYNAMECACHE TABLE. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV16616 APAR: IV16932 ----------------------- Title:THE DLA GENERATED XML FILE DOESN'T DESCRIBE DEVICE CONTAINMENT STRUCTURE CORRECTLY Link: https://www.ibm.com/support/docview.wss?uid=swg1IV16932 APAR: IV17575 ----------------------- Title:DEVICE EGRESS AND INGRESS TRAFFIC HEALTH SUMMARY REPORTS NEED TO FIT PDF LAYOUT AS WELL AS HTML LAYOUT Link: https://www.ibm.com/support/docview.wss?uid=swg1IV17575 APAR: IV18992 ----------------------- Title: CHANGE LOCALE ISSUE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV18992 APAR: IV19652 ----------------------- Title:TOPOVIZ NETWORK VIEW ICON LABEL TRUNCATED Link: https://www.ibm.com/support/docview.wss?uid=swg1IV19652 APAR: IV19896 ----------------------- Title:SNMP HELPER SHOULD FLAG AND REPLACE INVALID UTF-8 CHARACTERS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV19896 APAR: IV19902 ----------------------- Title: JUNIPERBOXANATOMY DISCOVERY AGENT CONTAINS INCORRECTLY AND DOESN'T COLLECT ENOUGH PHYSICAL INFORMATION Link: https://www.ibm.com/support/docview.wss?uid=swg1IV19902 APAR: IV20128 ----------------------- Title:ON AIX THE ITNM_STOP SCRIPT CAN SOMETIMES FAIL TO RETRIEVE THE PPID OF THE PROCESSES Link: https://www.ibm.com/support/docview.wss?uid=swg1IV20128 APAR: IV20184 ----------------------- Title:SNMP HELPER(NCP_DH_SNMP) DOES NOT PROCESS OTHER GENERIC COMMUNITY STRINGS WHEN PREVIOUSLY SUCCEEDED ONE FAILS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV20184 APAR: IV20521 ----------------------- Title: THE THE MPLSTE STITCHERS HAVE SCALING ISSUES IN ITNM 3.9 FP1 Link: https://www.ibm.com/support/docview.wss?uid=swg1IV20521 APAR: IV20645 ----------------------- Title:NCP_POLLING_EXCEPTIONS.PL FAILS WITH OUT-OF-MEMORY EXCEPTION WHEN NCIM DATABASE HAS MORE THAN MILLION Link: https://www.ibm.com/support/docview.wss?uid=swg1IV20645 APAR: IV20889 ----------------------- Title: SOME MPLS TE PATHS ARE NOT VISUALISED CORRECTLY Resolution: Fix CreateMPLSTEPipeHop stitcher to solve the issue above. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV20889 APAR: IV20914 ----------------------- Title:SHOW CONNECTIVITY TOOL DOES NOT SHOW VLAN/VPN AS DOES THE NETWORK VIEW DISPLAY Link: https://www.ibm.com/support/docview.wss?uid=swg1IV20914 APAR: IV21263 ----------------------- Title:GET_POLICIES.PL DOES NOT WORK CORRECTLY ON 3.9 WITH MYSQL Link: https://www.ibm.com/support/docview.wss?uid=swg1IV21263 APAR: IV22071 ----------------------- Title:BROKEN LINK ON CLASS NAME IN POLL POLICY Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22071 APAR: IV22259 ----------------------- Title:DEVICE AVAILABILITY SUMMARIZATION REPORT TEXT SHOWS ""INTERFACE AVAILABILITY SUMMARIZATION"" Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22259 APAR: IV22788 ------------- Title: UNMANAGE/MANAGE ACTION CAUSES BACKUP POLLER TO POLL DEVICE. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22788 APAR: IV22799 ----------------------- Title:SIZE OF NETWORK VIEW ICONS GETTING SQUEEZED WHEN DRAGGING AROUND. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22799 APAR: IV22823 ----------------------- Title:NCP_CTRL DO NOT HONOR THE RETRYCOUNT SET IN CTRLSERVICES.CFG FOR ANY CHILD PROCESS WHEN THE VALUE IS SET TO ZERO. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22823 APAR: IV22901 ----------------------- Title:LISTENTITIES.PL GIVES AN ERROR THAT IT CANNOT CONNECT TO DISCOVERY. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22901 APAR: IV22933 ----------------------- Title: DISCO IP MALFORM Link: https://www.ibm.com/support/docview.wss?uid=swg1IV22933 APAR: IV23003 ----------------------- Title: NCP_MODEL & NCP_CONFIG CORE DUMP DURING SHUTDOWN. ALSO,NCP_CTRL, AND NCP_CONFIG CORE ON BUSY SYSTEM. Link: http://www-01.ibm.com/support/docview.wss?uid=swg1IV23003 APAR: IV23058 ----------------------- Title:NOT ABLE TO DETERMINE THE LIFE CYCLE AND STATUS OF PING POLLS FROM THE POLLER Link: https://www.ibm.com/support/docview.wss?uid=swg1IV23058 APAR: IV23136 ----------------------- Title:BACKUP NCP_VIRTUALDOMAIN FAILS TO RESYNC WITH PRIMARY UPON LOSING CONNECTION WHILE RECEIVING AND PROCESSING TOPOLOGY Link: https://www.ibm.com/support/docview.wss?uid=swg1IV23136 APAR: IV23424 ----------------------- Title: NORTEL SWITCH AGENT DOES NOT QUERY STANDARD MIBS IF THE DEVICE DOES NOT SUPPORT PRIVATE MIBS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV23424 APAR: IV23863 ----------------------- Title: COLLECTOR ENDED SUDDENLY AT THE END OF ITS WORK DURING DISCOVERY. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV23863 APAR: IV24206 ----------------------- Title: DISCO GUI ACCUMULATES MEMORY DUE TO SQL RESULT SETS NOT CLOSED IN TIME LEADING TO OOM Link: https://www.ibm.com/support/docview.wss?uid=swg1IV24206 APAR: IV24388 ----------------------- Title: COREBUILDER3COMSWITCH AGENT FAILED DURING DISCOVERY DUE TO FATAL ERROR. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV24388 APAR: IV24718 ----------------------- Title:CONNECTIVITY BETWEEN PRIMARY AND BACKUP SERVER CAN BE LOST WHEN TRANSFERRING LARGE NUMBERS OF NETWORK VIEWS OR POLL POLICIES. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV24718 APAR: IV24844 ----------------------- Title:NCP_PERL CORE DUMP Link: https://www.ibm.com/support/docview.wss?uid=swg1IV24844 APAR: IV24928 ----------------------- Title:POLLER IS UPDATING VIEWS FOR POLICIES THAT ARE NOT ENABLED Link: https://www.ibm.com/support/docview.wss?uid=swg1IV24928 APAR: IV24939 ----------------------- Title:NEXUSCONTAINERS STITCHER DOESN'T WORK PROPERLY WHEN DEALS WITH MULTIPLE CISCO NEXUS DEVICES Link: https://www.ibm.com/support/docview.wss?uid=swg1IV24939 APAR: IV25131 ----------------------- Title:RCA FAILS TO SUPPRESS EVENTS FROM THE CHASSIS IP WHEN THE GRAPH ENDS ON AN INTERFACE WITH THE SAME IP. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25131 APAR: IV25264 ----------------------- Title: INCORRECT CONTAINMENT VIA THE JUNIPERLAGSTACK AGENT Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25264 APAR: IV25446 ----------------------- Title:PERFORMANCE IMPROVEMENTS TO THE CREATETRUNKCONNECTIONS STITCHER Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25446 APAR: IV25833 ----------------------- Title:NCP_DLA BOOK CREATION TAKES A LONG TIME ON INFORMIX. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25833 APAR: IV25842 ----------------------- Title: STACKED DEVICES NOT PROPERLY CONNECTED CAUSING PROBLEMS FOR POLLER Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25842 APAR: IV25872 ----------------------- Title:Network Manager FAILS TO RECONNECT TO ORACLE DATABASE AFTER AN ORA-03135 ERROR. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25872 APAR: IV25978 ----------------------- Title: JUNIPERBOXANATOMY AGENT CORES Link: https://www.ibm.com/support/docview.wss?uid=swg1IV25978 APAR: IV26274 ----------------------- Title:NCP_MODEL CAN CAUSE DEADLOCK IN NCIM DB(MYSQL ONLY) RESULTING INCORRECT DATA IN NCIM IN A MULTI-DOMAIN ENVIRONMENT Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26274 APAR: IV26368 ----------------------- Title:RESOLVE LINGERTIME ISSUE WITH PERMANENTLY UNMANAGED DEVICES Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26368 APAR: IV26372 ----------------------- Title: MEMORY LEAK IN NCP_DISCO PROCESS WHEN HANDLING LARGE AMOUNTS OF BGP DATA Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26372 APAR: IV26406 ----------------------- Title:BACKUP MODEL DELETES THE EXISTING TOPOLOGY UPON SEEING NO RESPONSE FROM PRIMARY IN A NCIM FAILOVER ENVIRONMENT Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26406 APAR: IV26410 ------------ Title:DATABASE LOCKING IN POLLER Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26410 APAR: IV26591 ----------------------- Title: WHEN MULTIPLE DATASOURCES ARE DEFINED, STATUS FOR NETWORKVIEWS AND HOPVIEW IS ONLY DISPLAYED FOR FIRST DATASOURCE WEBGUI APAR Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26592 Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26591 APAR: IV26605 ----------------------- Title:POLLER CONTINUES TO POLL OLD ACCESSIPADDRESS INSTEAD OF NEW IP WHEN THE OLD IPADDRESS NO LONGER EXIST IN NCIM. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26605 APAR: IV26715 ----------------------- Title:FALSE PING FAIL EVENTS GENERATED WHEN NTP CLOCK ADJUSTMENTS ARE MADE. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26715 APAR: IV26837 ----------------------- Title: CISCOSWITCHSNMP AGENT DOESN'T PROCESS VLANINDEX > 1023 IN M_TRUNKEDVLANS ALTHOUGH IT'S CONFIGURED Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26837 APAR: IV26842 ------------------------ Title:WRONG FORMAT OF TIME IN EXCEL REPORT. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV26842 APAR: IV27231 ----------------------- Title:AE IV25255 FIX COMPLETION: NCP_MODEL 'ORDER BY' CORE MORE FREQUENT SINCE THE 'ORDER BY' CORE FIX. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27231 APAR: IV27341 ----------------------- Title: BACKUP MODEL FAILS TO PROCESS CORRECTLY ALL CONNECTIONS RESULTING BACKUP NCIM.CONNECTS TABLE WITH EXCESS CONNECTIONS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27341 APAR: IV27515 ----------------------- Title:POLLER DIES AND RESTARTS WHILE PROCESSING TOPOLOGY UPDATES WHEN AN INTERFACE IPADDRESS CHANGES FROM IP TO NULL Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27515 APAR: IV27599 ----------------------- Title:IN FAILOVER ENVIRONMENT, BACKUP POLLER IS UPDATING NETWORKVIEWS WHEN IT IS IN STANDBY MODE RESULTING IN NCIM TABLE LOCKS" Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27599 APAR: IV27616 ----------------------- Title:MODEL DOES NOT BROADCAST LINGERTIME CHANGES APPROPRIATELY ON THE MESSAGE BUS TO POLLER Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27616 APAR: IV27886 ----------------------- Title:NCP_MODEL PROCESS USING EXCESSIVE AMOUNTS OF MEMORY Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27886 APAR: IV27953 ----------------------- Title:NCP_MIB DOES NOT PROPERLY PARSE MODULE DEFINITION WITH MORE THAN 2 ITEMS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV27953 APAR: IV28583 ----------------------- Title:LISTENER THREADS OPENED AND NEVER CLOSED RESULTING IN HIGH MEMORY USAGE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV28583 APAR: IV28595 ----------------------- Title:GET_POLICIES.PL GENERATE NOT WELL-FORMED .XML FILES WHEN DEALING WITH NON-ASCII CHARACTERS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV28595 APAR: IV28613 ----------------------- Title:POLLER IS DOING DUPLICATE EFFORT OF TESTING SNMP CREDENTAILS DURING STARTUP, FAILOVER AND FAILBACK SCENARIOS. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV28613 APAR: IV28640 ----------------------- Title:POLLER CAN SOMETIMES READ THE SNMPKEYCHAIN TABLE WHILE IT IS BEING UPDATED BY HELPER RESULTING IN INCOMPLETE KEYCHAIN LISTS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV28640 APAR: IV28694 ----------------------- Title:ADDED SUPPORT TO ALLOW ""_"" IN DB ACCOUNT USER NAME. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV28694 APAR: IV29152 ----------------------- Title: WHEN MODIFYING TIMING IN A STITCHER, OLD TIME OR INTERVAL NOT REMOVED Link: https://www.ibm.com/support/docview.wss?uid=swg1IV29152 APAR: IV29544 ----------------------- Title:IN HOPVIEW IP SUBNETS DROP DOWN SELECT RESULTS ARE INCORRECT Link: https://www.ibm.com/support/docview.wss?uid=swg1IV29544 APAR: IV29897 ------------- Title: ADAPTIVE POLLING IS NOT EFFECTIVE WHEN USERS ARE ACTIVELY NAVIGATING THROUGH NETWORKVIEWS DUE TO DATABASE LOCKS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV29897 APAR: IV29988 ----------------------- Title:SECOND WEBTOOL USER FAILS WHEN EXECUTING SIMULTANEOUSLY Link: https://www.ibm.com/support/docview.wss?uid=swg1IV29988 APAR: IV30387 ----------------------- Title:POLL POLICY OR DEFINITIONS SCOPED USING INTERFACE FILTERS NOT HANDLING MODEL UPDATES PROPERLY RESULTING IN LOSS OF POLLING. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30387 APAR: IV30422 ----------------------- Title: WHEN IN DEBUG 4, SOMETIMES AFTER LOG FILE ROTATION, TRACING STOPS WRITING STDOUT Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30422 APAR: IV30443 ----------------------- Title:SAVE AS IMAGE IN GUI DOES NOT HAVE WRITE PERMISSIONS Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30443 APAR: IV30445 ----------------------- Title:DEFAULTLICGRAPHPERIOD ALWAYS SET TO 1 IN PROPERTIES FILE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30445 APAR: IV30508 ----------------------- Title:POLLER CORES WHEN TRACE GOES OVER 2GB Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30508 APAR: IV30619 ----------------------- Title:FUNCTIONALITY TO REDUCE THE NUMBER OF REGISTERED WEBTOP TRANSIENT ENTITIES IN ORDER TO SAVE MEMORY. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30619 APAR: IV30624 ----------------------- Title:Model process should honour LingerTime values set by the Disco process. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30624 APAR: IV30706 ----------------------- Title:TRANSLATION OF TIME PERIOD READS "PAST 1 YEAR" BUT CORRECT TRANSLATION SHOULD BE "YEAR TO DATE" Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30706 APAR: IV30730 ----------------------- Title: NETWORK MANAGER IP EDITION 2012 INTEGRATIONS R1 (3.9) Problem: Support added for the following: Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30730 APAR: IV30775 ----------------------- Title:STITCHERPROFILING FEATURE CAUSES SLOWDOWN IN WORKING ENTITIES POPULATION RESULTING INCREASED DISCOVE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30775 APAR: IV30811 ----------------------- Title:LISTENTITIES.PL FAILS TO POPULATE MANUFACTURERS COLUMN. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30811 APAR: IV30848 ----------------------- Title: WHEN NCP_G_EVENT ON THE BACKUP SERVER IS ACTING AS A PRIMARY, IF IT DIES, IT IS RESTARTED AS BACKUP Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30848 APAR: IV30850 ----------------------- Title:PRIMARY DOMAIN POLLER DOES NOT STOP PRUNING HISTORICAL DATA WHEN IN FAILOVER MODE. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30850 APAR: IV30854 ----------------------- Title:MEMORY LEAK IN NCP_POLLER Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30854 APAR: IV30911 ------------------------ Title: BY DEFAULT LOG FILES CAN GROW UNLIMITED IN SIZE. IN ADDITION THE DOCUMENTATION SAYS THE DEFAULT LIMIT IS 102400 BYTES. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV30911 APAR: IV31166 ----------------------- Title:ON-DEMAND TRANSIENT WEBTOP ENTITIES REGISTRATION OF PARENT NETWORK VIEWS IN NETWORK VIEW TREE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31166 APAR: IV31168 ----------------------- Title:COLLECTION VIEWS DO NOT WORK ON FP2 Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31168 APAR: IV31221 ----------------------- Title:INTERMITTENT GATEWAY CORE DURING A TOPOLOGY UPDATE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31221 APAR: IV31293 ----------------------- Title:MANAGE TOOL IN NETWORK HOP VIEW'S STRUCTURAL BROWSER PORTLET DOES NOT WORK Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31293 APAR: IV31294 ----------------------- Title:REMOVING NCP_AUTH FROM THE PRODUCT. NCP_OQL . Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31294 APAR: IV31348 ------------ Title:NCIM DATA LOSS DO TO BACKUP Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31348 APAR: IV31549 ----------------------- Title:- Functionality to automatically restart discovery process on a full discovery Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31549 APAR: IV31562 ----------------------- Title:SPEED UP MODEL'S NCIM TRANSFER TIME AND STORE PROFILING DATA ON Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31562 APAR: IV31581 ----------------------- Title:SEVERAL STITCHER PERFORMANCE IMPROVEMENT INCLUDED IN FP3. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31581 APAR: IV31635 ----------------------- Title:NEGATIVE TIME SHOWING IN DISCOVERY GUI Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31635 APAR: IV31637 ----------------------- Title: SOMETIMES THE DISCOVERY STATUS GUI SHOWS THE WRONG STATUS (STOPPED) AND A RUNNING DISCOVERY CANNOT BE STOPPED Link: https://www.ibm.com/support/docview.wss?uid=swg1IV31637 APAR: IV32321 ----------------------- Title:USE DATABASE RECURSION WHEREVER IS POSSIBLE IN THE Network Manager GUI Link: https://www.ibm.com/support/docview.wss?uid=swg1IV32321 APAR: IV32323 ------------------------ Title: USE DATABASE BATCH INSERT WHEREVER IS POSSIBLE IN THE Network Manager GUI Link: https://www.ibm.com/support/docview.wss?uid=swg1IV32323 APAR: IV32342 ----------------------- Title: Network Manager 3.9 FAULT FINDING VIEW DISPLAYS POPUP Link: https://www.ibm.com/support/docview.wss?uid=swg1IV32342 APAR: IV32418 ----------------------- Title: INFORMIX NCPOLLDATA.KNP_POLL_DATA_COLLECTION.POLLTIME ALWAYS SHOWS NULL ACCESSED BY NCP_OQL SERVICE NCIM Link: https://www.ibm.com/support/docview.wss?uid=swg1IV32418 APAR: IV32431 ----------------------- Title:PLACEMENT OF NEW NODES IN THE MAP AFTER DISCOVERY. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV32431 APAR: IV32842 ----------------------- Title: Database schema change for performance and scaling improvements Link: https://www.ibm.com/support/docview.wss?uid=swg1IV32842 APAR: IV33100 ----------------------- Title:NCP_POLLER FAILURE WHILE CHECKING FOR DUPLICATES Link: https://www.ibm.com/support/docview.wss?uid=swg1IV33100 APAR: IV33113 ------------------------ Title:POLLER STOPS POLLING THE IP WHEN DUPLICATE IPADDRESS IS FOUND WITH SAME LINGERTIME Link: https://www.ibm.com/support/docview.wss?uid=swg1IV33113 APAR: IV33618 ----------------------- Title: DEADLOCK MAY OCCUR IS MANAGED STATUS POLL IS NOT SUSPENDED BEFORE TRYING TO APPLY OQL UPDATE Link: https://www.ibm.com/support/docview.wss?uid=swg1IV33618 APAR: IV35487 ----------------------- Title:POLLER INCORRECTLY STOPPING THE MONITORS WHILE PROCESSING THE TOPOLOGY UPDATES UPON COMPLETION OF DISCOVERY. Link: https://www.ibm.com/support/docview.wss?uid=swg1IV35487 APAR: IV36477 ----------------------- Title: OQL OPTIMIZATION Link: https://www.ibm.com/support/docview.wss?uid=swg1IV36477 APAR: IV47466 ------------- Title:UPDATE THE VERSION OF GSKIT 8.0.14.23 USED BY ITNM 3.8 &3.9 Link: http://www-01.ibm.com/support/docview.wss?uid=swg1IV47466 =============================================================================== Contacting IBM Support ============================================================================== Please use the IBM Software Support website: http://www-01.ibm.com/software/support/exchangeinfo.html =============================================================================== |
. Network Manager V3.9 or earlier 3.9 Fix Packs must be installed before applying this Fix Pack.
. Ensure that there is approximately 1 GB of free space on the drive on which the product was installed.
. Windows 2008 imposes a limit of 260 characters for the full name (including path) of a file.
Network Manager 3.9 Fix Pack 2 and later fix packs already have some very long directory names
because the fix pack contains updates from many components such as WebSphere, TIP, TCR,
which by themselves are up to 221 characters in length, including separators. Therefore Windows
users are advised to select a location for the compressed Network Manager 3.9 Fix Pack image
on their machine so that when extracted, the resulting file names are less than 260 characters.
For example, C:\Build will work as a location for the fix pack image, but
C:\Users\Administrator\Desktop\Test will not.
Full details on installation prerequisite for this fixpack can be found in the
3.9.0_INSTALL_FP0003 file.
Full details on installation prerequisites and installation steps for this fixpack can be found in the
3.9.0_INSTALL_FP0003 file, which is downloadable from the link below..
NOTE:
If upgrading an existing IBM Tivoli Network Manager (ITNM) 3.9 installation that is using Tivoli Integrated Portal (TIP) version 2.1 to use TIP version 2.2, you will need the TIP FIT package. The TIP FIT package contains a TIP signature file used with TIP 2.2 Fix Packs and Feature Pack. Additional fix packs for TIP 2.2 can be applied after TIP 2.2.0.1 (Feature Pack), such as TIP 2.2.0.9. Each fix pack of TIP 2.2 (such as TIP 2.2.0.9) will have a separate TIP FIT package / signature file associated with it.
To obtain the TIP signature files, download them from Fix Central -->
http://www-933.ibm.com/support/fixcentral/swg/selectFixes?parent=ibm~Tivoli&product=ibm/Tivoli/Tivoli+Integrated+Portal&release=All&platform=All&function=all
From the TIP support team, the FIT packaging is bit different from TIP 2.2.0.1 to TIP 2.2.0.9. In TIP 2.2.0.9, FIT package you will not see any "input" folder and the signature file will be part of FIT.jar.
Please use the same user id that you used to install the product/fix pack to extract these and then run the fix pack installer.
URL | LANGUAGE | SIZE(Bytes) |
---|---|---|
3.9.0_INSTALL_FP0003 | US English | 49291 |
3.9.0_README_FP0003 | US English | 54035 |
3.9.0_INSTALL_NLS_FP0003 | Language Independent | 180345 |
3.9.0_README_NLS_FP0003 | Language Independent | 115419 |
Download | RELEASE DATE | LANGUAGE | SIZE(Bytes) | Download Options |
---|---|---|---|---|
3.9.0-TIV-ITNMIP-AIX-FP0003 | 15 Feb 13 | Language Independent | 1336287787 | HTTP |
3.9.0-TIV-ITNMIP-zLinux-FP0003 | 15 Feb 13 | Language Independent | 1328930245 | HTTP |
3.9.0-TIV-ITNMIP-Solaris-FP0003 | 15 Feb 13 | Language Independent | 1208326615 | HTTP |
3.9.0-TIV-ITNMIP-Windows-FP0003 | 15 Feb 13 | Language Independent | 1103519312 | HTTP |
3.9.0-TIV-ITNMIP-Linux-FP0003 | 15 Feb 13 | Language Independent | 1253657520 | HTTP |
Problems (APARS) fixed
IZ93148, IV04119, IV05220, IV06737, IV10323, IV10934, IV12927, IV14221, IV16149, IV16616, IV16932, IV17575, IV18992, IV19652, IV19896, IV19902, IV20128, IV20184, IV20521, IV20645, IV20889, IV20914, IV21263, IV22071, IV22259, IV22788, IV22799, IV22823, IV22901, IV22933, IV23003, IV23058, IV23136, IV23424, IV23863, IV24206, IV24388, IV24718, IV24844, IV24928, IV24939, IV25131, IV25264, IV25446, IV25833, IV25842, IV25872, IV25978, IV26274, IV26368, IV26372, IV26406, IV26410, IV26591, IV26605, IV26715, IV26837, IV26842, IV27231, IV27341, IV27515, IV27599, IV27616, IV27886, IV27953, IV28583, IV28595, IV28613, IV28640, IV28694, IV29152, IV29544, IV29897, IV29988, IV30387, IV30422, IV30443, IV30445, IV30508, IV30619, IV30624, IV30706, IV30730, IV30775, IV30811, IV30848, IV30850, IV30854, IV30911, IV31166, IV31168, IV31221, IV31293, IV31294, IV31348, IV31549, IV31562, IV31581, IV31635, IV31637, IV32321, IV32323, IV32342, IV32418, IV32431, IV32842, IV33100, IV33113, IV33618, IV35487, IV36447, IV07908, IV08858, IV11080, IV11558, IV11724, IV12417, IV12850, IV12852, IV13225, IV13306, IV13415, IV13821, IV13837, IV14984, IV15724, IV15474, IV15667, IV15884, IV16076, IV16501, IV16617, IV16972, IVI7003, IV17407, IV17974, IV18035, IV18079, IV18264, IV19065, IV19168, IV19196, IV19213, IV19228, IV19607, IV19690, IV19726, IV19812, IV19825, IV19909, IV20134, IV20201, IV20360, IV20529, IV20642, IV20916, IV21442, IV21443, IV21587, IV21588, IV21589, IV21663, IV21789, IV21935, IV21970, IV21972, IV21975, IV21990, IV22011, IV22243, IV22553, IV22562, IV22899, IV22900, IV22902, IV22903, IV22994, IV22997, IV22998, IV23003, IV23008, IV23011, IV23055, IV23278, IV24089, IV24128, IV24247, IV24249, IV24421, IV24617, IV24795, IV24945, IV25254, IV25255, IV25256, IV23278, IZ88972, IZ81036, IZ84399, IZ85441, IZ85921, IZ86011, IZ86201, IZ87271, IZ87567, IZ88605, IZ89794, IZ90247, IZ91113, IZ92126, IZ92339, IZ92490, IZ92509, IZ94332, IZ94405, IZ94550, IZ94642, IZ94749, IZ94826, IZ95110, IZ95507, IZ95608, IZ95646, IZ96015, IZ96016, IZ96220, IZ96242, IZ96285, IZ96537, IZ96931, IZ96937, IZ97314, IZ97409, IZ97548, IZ97974, IZ98083, IZ98663, IZ98723, IZ98726, IZ99012, IZ99308, IZ99474, IZ99855, IV00140, IV00034, IV00366, IV00411, IV00446, IV00602, IV00672, IV00818, IV00848, IV00908, IV00926, IV01020, IV01100, IV01170, IV01535, IV01549, IV01587, IV01592, IV01614, IV01634, IV01669, IV01706, IV02082, IV02127, IV02229, IV02407, IV02671, IV02808, IV02909, IV02995, IV03085, IV03086, IV03128, IV03133, IV03378, IV03413, IV03486, IV03631, IV03642, IV03865, IV03968, IV04074, IV04075, IV04531, IV04718, IV05797, IV06195, IV06240, IV06272, IV06321, IV06337, IV06455, IV06477, IV06712, IV06743, IV06779, IV06791, IV07103, IV07104, IV07249, IV07631, IV07647, IV07692, IV07753, IV07856, IV07982, IV07909, IV08015, IV08018, IV08027, IV08192, IV08381, IV08412, IV08604, IV08768, IV08981, IV09035, IV09209, IV09214, IV09221, IV09223, IV09228, IV09229, IV09231, IV09255, IV09256, IV09257, IV09258, IV09454, IV09898, IV10323, IV11080, IV11088, IV11270, IV11271, IV11558, IV11669, IV11761, IV11827, IV11863, IV12280, IV12461, IV13720, IV15328, IV15330, IV15334, IV15377
Known issues with V3.8.0 Fix Pack 7
=============================================================================
Known problems are documented in the form of individual Technotes in the Support knowledge base.
Go to the following link to perform an advanced search of the knowledge base:
http://www-01.ibm.com/software/sysmgmt/products/support/IBMTivoliNetworkManagerIPEdition.html
Go to the following link to retrieve all technotes for version 3.8 of Network Manager:
http://www-01.ibm.com/support/search.wss?tc=SSSHRK&q=technote+3.8
Installing the V3.8.0 Fix Pack 7
=============================================================================
Full details on how to install this fix pack can be found in the INSTALL file, which can be downloaded below.
Summary of fixes in V3.8.0 Fix Pack 7
=============================================================================
List of all customer-reported issues that have been fixed in this fix pack,with a link to the fix description for each issue.
APAR: IV00342
-------------
Abstract: NCP_TRAPMUX FORWARDS TRAP PACKETS USING INCORRECT LENGTH
Description: When routing snmp traps through the ncp multiplexor, it appears that while
it will receive the trap ok it only will forward out 1024 bytes.If the trap is longer than
that, it just truncates the trap.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00342
APAR: IV00602
-------------
Abstract: ITNMV3.8 DNS LOOKUP TOOL ERROR
Description: When an attempt is made to use the tool DNS Lookup in TopoViz (ITNM client in
TIP/Web GUI) or launching the DNS Lookup tool from ITNM GUI,the tool fails with the error.
This occurs even if the Domain name is changed from the default domain name.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00602
APAR: IV00818
-------------
Abstract: POLLER EXITS UNEXPECTEDLY WHEN DB2 IS NOT AVAILABLE.
Description: Symptom: Poller exits and generates core file when DB2 is not available.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00818
APAR: IV01020
-------------
Abstract: ITNM38 TRUNK PORTS PLACED IN DUMMY GROUP.
Description: Trunk ports that are administratively down are placed in "dummy
cards" group and not in the correct fixed module group.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01020
APAR: IV01170
-------------
Abstract: ITNM_STATUS NCO COMMAND TRIES TO SHOW THE STATUS OF ALL MANAGED
PROCESSES IN THE PA INSTEAD OF ONLY network manger ONES.
Description: Currently when running the itnm_status nco script we are getting
all the processes under the PA in the Omnibus instead of only the network manger related
ones ( PA, objserver, mttrapd ). Additionally, the status of the other PA processes is not always correct, which
may lead to some confusion about the true status of those processes.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01170
APAR: IV01320
-------------
Abstract: MARKING DEVICES AS UNMANAGED WHEN THE BACKUP DOMAIN IS
ACTING PRIMARY FAILS TO SET NMOSMANAGEDSTATUS IN PROBE EVENTS
Description: Unmanage a device when in failover mode, with the backup domain
having become the acting primary domain, unmanage one of the
devices. Events from the network manger poller are correctly suppressed.
However, events from other sources, such Syslog or Mttrapd
(SNMP) probe fail to have the NmosManagedStatus field set
correctly to 1. This means they show up on Event Lists that
use NmosManagedStatus to filter out events from devices that
are known to be unmanaged.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01320
APAR: IV01535
-------------
Abstract: POLLER CONTINUES TO POLL AN UNMANAGED CHASSIS
Description: Customer can unmanage a chassis from the gui (hopview) and can
still see polling traffic going to that entity. It appears to only be snmp poll traffic because
the tcpdump shows ICMP echos stop when unmanaged.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01535
APAR: IV01549
-------------
Abstract: WHEN RIGHT CLICKING AND CHOSING TO "GRAPH SNMP MIB DATA" ERROR
RECEIVED "... HOST CANNOT BE FOUND IN THE NCIM DATABASE"
Description: 1) In hop view, I searched for the node in the domain. Select
this node.
2) When the view shows up, I right clicked and chose to "Graph
SNMP MIB Data". I go to the second tab, select any poll.
3) When I select "OK" to graph the data, I receive the message:
"The specified host cannot be found in the NCIM database. Please
choose another." This is caused when no interface record exists in scratchTopology with an m_IpAddress of the chassis.
Action:
The fix is to check for chassis objects that have no corresponding interface records in CreateScratchTopology and tag them.
A change to ModelNcimDb.cfg will create records in the ipEndPoint table for chassis that have been tagged.
If the NCHOME/etc/precision/ModelNcimDb.cfg has been customized before, then the existing file should be merged with
NCHOME/etc/precision/default/ModelNcimDb.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01549
APAR: IV01634
-------------
Abstract: JAVA.LANG.CLASSCASTEXCEPTION IN JAVA CONSOLE
Description: java.lang.ClassCastException in Java Console caused by fix for IZ96220.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01634
APAR: IV01669
-------------
Abstract: THE SAVED NETWORK VEIW LAYOUT CHANGED TO ORIGINAL AFTER DOMAIN
RESTART WHERE DISPLAY LABELS CONTAIN MUITI-BYTE CHARATERS
Description: The saved network view layout changed to original after domain
restart where devices' display labels contain muiti-byte characters.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01669
APAR: IV01706
-------------
Abstract: HOP VIEW URL IGNORES DOMAIN PARAMETER
Description: HopView URL are not working in multi domain.
HopView ignores the 'domain' parameter and so it does
not work in multidomain environments, where the 'domain' parameter is required.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV01706
APAR: IV02082
-------------
Abstract: DBI_FACTORY.PM NEEDS TO BE ALTERED TO ENABLE LOCAL DB2 CATALOG
USE IN HADR ENVIRONMENT.
Description: Running any script that uses ncp_perl, for example RemoveNode.pl
returns the following: Connecting to database.
critical: Database Connection Error: [IBM][CLI Driver] SQL30081N
A communication error has been detected. Communication protocol
being used: "TCP/IP". Communication API being used: "SOCKETS".
Location where the error was detected: "1.1.1.1".Communication function detecting the error: "connect".
Protocol specific error code(s): "111", "*", "*".
SQLSTATE=08001 (where "1.1.1.1" represents the IP address for the socket).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02082
APAR: IV02127
-------------
Abstract: POLLER FAILED TO RECOGNISE SQLSTATE 40003 AS A DISCONNECT FROM
THE DATABASE.
Description: The poller fails to recognized the SQLState message number 40003
as a disconnect message. As a result it does not try to recover the connection.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02127
APAR: IV02229
-------------
Abstract: ARGUMENT TO NCP_CTRL -LOGDIR SWITCH NOT HONOURED CORRECTLY WHEN IT IS NOT THE DEFAULT DIRECTORY
Description: Normally, the -logdir switch for ncp_ctrl can be used to control
where all log and trace files are placed for the domain being
run.Only the first few lines of the trace files appear in the specified directory, while the remainder appear in the default location.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02229
APAR: IV02407
-------------
Abstract: MALFORMED ERROR IN UDP PACKET SENT WHEN TRACEROUTE AGENT IS ENABLED.
Description: Bad length value 2048 > IP payload length
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02407
APAR: IV02671
-------------
Abstract: NCP_POLLER PROCESS DEADLOCKS IN CERTAIN SITUATIONS WHEN FAILOVER IS CONFIGURED
Description: After starting up, the poller stops polling.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02671
APAR: IV02808
-------------
Abstract: WRENCH ICON CAN TAKE A LONG TIME TO APPEAR
Description: When there are a large number of entities in the view,
it can take some minutes for the wrench icon (or spanner icon)
to appear when you right click on a device a select "Unmanage".
The same is not true when there are a small number of entities in the view.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02808
APAR: IV02846
-------------
Abstract:THE 'PLUS' BUTTON IN TRIGGER CONDITION TAB DOES NOT WORK.
Description: When creating a new poll definition (generic or basic threshold).
The plus sign (to add another condition) in the trigger threshold tab does not work. It produces errors:
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02846
APAR: IV02995
-------------
Abstract: ITNM_ CONTROL SCRIPTS CAN FAIL WHEN PROCESS ID IS LESS THAN 5
DIGITS AND TWO PROCESSES MATCH THE PATTERN
Description: The pattern in script allows for multiple process IDs to be matched where one of the processes is less than 5 digits in length.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV02995
APAR: IV03128
-------------
Abstract: ITNM3.9 LARGE NETWORK VIEW STALLS TIP
Description: When creating a large number of views the tip, java
process will use all available memory and stop working. The
views won't be displayed.Further editing isn't possible until
the views are deleted from the ncpoller db.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03128
APAR: IV03133
-------------
Abstract: CREATETRUNKCONNECTIONS STITCHER FIX.
Description: Customer is using network manger in a multiple virtual machines environment
connected on a switch port that is a trunking VLAN.
The stitcher is connecting each of the VLAN trunk end points
directly to the VMs. This meant that in cases where there were
many VMs connected to the same physical switch port a large
number of connections were being created ( numConnections =
numberofVLANs * numberOfVMs ).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03133
APAR: IV03148
-------------
Abstract: MULTI TABS PROBLEM ON ITNM3.8
Description: The below 2 issues always occur, while following the steps.
Issue-1:
1> Open "Discovery Configuration" , select DomainA and make some
change in the advanced. Do not save.
2> Open "Discovery Status", select DomainB. Do nothing.
3> Go back to "Discovery Configuration", still red words remind
you to save the change and the domain drop-down list is still
domainA.
4> Click the 'save' button. Saved, and the domain drop-down list
refreshed from DomainA to DomainB(sync with the drop-down list
of "Discovery Status"?), but the configurations in the webpage
are still of DomainA.
5> Click the 'save' button again, DomainB scope config over-writed by DomainA's
Issue-2:
1> Start the discovery for DomainA and DomainB
During the disco process, execute the following steps.
2> Open "Discovery Status" and select DomainA
3> Open "Discovery Config" and select DomainB
(select different Domain from step1).
=> verify the message "Downloading..."
4> Back to "Discovery Status", where the domain drop-down list
is still domainA, and Click "Stop" button.
=> then Discovery process for domainB stopped while we meant
to stop domainA's.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03148
APAR: IV03378
-------------
Abstract: FILTER WAS NOT ENCLOSED IN BRACKETS WHICH LEAD TO INADEQUATE
RESULTS WHEN THE FILTER CLAUSE HAS MORE THAN ONE STATEMENT.
Description: 2 domains that contains identical devices. When we try to create
a specific view, for a specific domain, all devices which are in
the ncim DB are included even if there are not in the same domain. Devices have 2 separate entityID.
Filter was not enclosed in brackets which lead to inadequate results when the filter clause has more than one statement.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03378
APAR: IV03670
-------------
Abstract: INSTALLER NEEDS TO CHECK THAT THE USER INSTALLING ITNM HAD
ACCESS TO THE DIRECTORY ABOVE NETCOOL
Description: The user is installing network manger into a directory called netcool and doesn't have access to the directory above.
You are installing network manger as a not root user to the path: /ITNM_3.9/NoAccess/Netcool.The installed has a built in logic to not create a directory
called netcool under an existing Netcool directory. The installer will try and
create the TIPV2 in on the same level as the Netcool directory which the user installing network manger doesn't have access to.
This will cause the installer to fail and report a "Catastrophic failure encountered when creating installation plan."
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03670
APAR: IV03865
-------------
Abstract: MIB BROWSER SNMP GET HANDLING INCORRECT FOR SCALAR VALUES
Description: 1.start SNMP MIB browser 2.select sysName of system mib Group from the tree 3. add index '0' to OID box
and then run SNMP GET request (such as 1.3.6.1.2.1.1.5.0 <= 0 was
added) 4. got result (without fail) and Name shows like 1.3.6.1.2.1.1.5.0.0
<= another 0 was added. 5. then for next request, he omit the index '0' such as
1.3.6.1.2.1.1.5 <= no '0' was added 6. got result (without fail) and Name shows sysName.0. He thinks that the result 4. and 6. are both wrong.
He assume with 4. Name shows 1.3.6.1.2.1.1.5.0. He assume with 6. the request gets failed..(SNMP GET-NEXT results same as his assumptions).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03865
APAR: IV03968
-------------
Abstract: BACKUP POLLER WILL ATTEMPT TO TRUNCATE NCPOLLDATA.POLLDATA WHEN NOT ACTING PRIMARY.
Description: In a failover environment, the backup poller will attempt to
truncate the stored data in ncpolldata.polldata at the same time
as the Primary poller is taking the same action. This can cause a deadlock on the database.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV03968
APAR: IV04053
-------------
Abstract: NODE NAMES LONGER THAN 45 CHARACTERS GET TRUNCATED IN STRUCTURE BROWSER
Description: Node names which are longer than 45 characters get truncated and
at the end three dots (...) get appended. Customers would like
to be able to see the full name of the node.
If the TIPHOME/profiles/TIPProfile/etc/tnm/structurebrowser.properties file has been customized before,
then the existing file should be merged with TIPHOME/profiles/TIPProfile/etc/tnm/default/structurebrowser.properties with the appropriate value set.
Implemented a new configurable field structurebrowser.tree.node.name.maxLength=0 in structurebrowser.properties file.
To activate the function, add the following lines to the TIPHOME/profiles/TIPProfile/etc/tnm/default/structurebrowser.properties file.
# Length at which the navigation tree should truncate the node name
# Default is 0, meaning that no truncation will take place.
# structurebrowser.tree.node.name.maxLength=0
http://www-01.ibm.com/support/docview.wss?uid=swg1IV04053
APAR: IV05797
-------------
Abstract: WHEN USING NCIM REPLICATION MODE, THE BACKUP NCP_MODEL FAILS TO
SUCCESSFULLY MIGRATE DATA TO NCIM
Description: When network manger is configured to use NCIM Failover mode, Backup ncp_model does not migrate data to NCIM correctly.
As a result, ncim.connects & ncim.topology links content in the
backup NCIM is not same as Primary NCIM. Though, the actual
number of entities i.e. ncim.entity matches between both.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV05797
APAR: IV06272
-------------
Abstract: NETWORK VIEWS ARE SLOW OR HANG DURING DISCOVERY.
Description: When a discovery is being performed or we fake a discovery by
updating the ncim.domainMgr table, the Network Views are very
slow to respond for a while afterwards. This is due to the
Network View caches being refreshed and locking the domainMgr table each time.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06272
APAR: IV06477
-------------
Abstract: XML RESPONSE FROM SAM COLLECTOR CAUSES COLLECTOR TO EXIT
Description: XML response from the SAM
may not always include characters that the XML parser
we use can parse. This causes the Collector to exit.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06477
APAR: IV06779
-------------
Abstract: TRACEROUTE AGENT CAUSES UDP PACKET FROM PORT 0 CAUSING FIREWALL
ERROR
Description: When the traceroute agent is enabled, UDP packets are sent at
the behest of the agent that come from TCP Source Port 0. This
can cause firewall issues as many firewalls check for packets
originating from port 0, and blocking such packets.
Implemented a new configurable field m_UdpSrcPort in DiscoPingHelperSchema.cfg.
It will be used as the SrcPort for the TraceRoute udp packet sent.Implemented a new
configurable field m_UdpSrcPort in DiscoPingHelperSchema.cfg. It will be used as the
SrcPort for the TraceRoute udp packet sent.
If the NCHOME/etc/precision/DiscoPingHelperSchema.cfg file has been customized before, then the existing file should be merged with
NCHOME/etc/precision/default/DiscoPingHelperSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06779
APAR: IV06841
-------------
Abstract: DLA ARE NOT PROPERLY RECONCILLED WITHIN TADDM, SUCH AS WHEN
THE SIGNATURE ATTRIBUTE DIFFERS FOR THE SAME DEVICE
Description: In some instances the devices exported by the
DLA are not properly reconciled within TADDM, such as when
the Signature attribute differs for the same device.
By using the ncp.dla.signatureOverride property you can
manually configure the Signature used by the DLA on a per-
device basis, thus bypassing automated Signature generation.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV06841
APAR: IV07103
-------------
Abstract: KNP AGENT NOT PASSING HISTORICAL DATA TO TDW
Description: The customer has an agent instance configured to migrate 100000
rows but the database has less than 100000 rows when this was
configured. The agent tries to migrate the data for the timestamp when the
configuration changed and it will just update the timestamp when
there are 100000 rows. In this scenario this will never
happen and the agent will get stuck on a query that never
returns data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07103
APAR: IV07624
-------------
Abstract: ITNM3.8 SYMPTOM ALERTS THAT CLEAR THEN ALERT AGAIN GET
INCORRECTLY MARKED AS ROOT CAUSE
Description: Two alerts are correctly raised as root cause and symptom. If the
symptom alert clears and then alerts again it gets incorrectly
marked as root cause.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07624
APAR: IV07631
-------------
Abstract: SNMP STACK NEEDS REPORTABLEFLAG TO BE SET TO 1 IN SOME CASES
Description: The reportable Flag needs to be set to 1 in case of possible
packet that can not be decoded by target device.
For latest Huaway firmware the devices expects the flag to be
set to 1, but it is not during the SNMP GetNext statements
issued by network manger. We need a change to the network manger
SNMP stack such that it checks the PDU type that its is about to send and sets the reportableFlag accordingly.
This means that we'd be able to successfully discover the Huawei devices with this new firmware.
In theory this could impact discovery of other vendors equipment
via SNMPv3 but if they are following the standard then they
should be ignoring the reportable Flag so this is a relatively
low risk.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07631
APAR: IV07647
-------------
Abstract: NETSCREENINTERFACE AGENT CRASHED DUE TO MEMORY LEAK
Description:NetScreenInterface agent crashed due to memory leak and
mismatched number of ifDescr/ifSpeed in some of the NetScreen devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07647
APAR: IV07753
-------------
Abstract: NETWORK MANAGER IP EDITION 2011 INTEGRATIONS R3 (3.9)
Description: Support added for the following discovery Agents:
(1) Juniper Box Anatomy Discovery Agent for Juniper Physical
Inventory discovery
(2) HSRP Secondary Virtual IP Discovery Agent for HSRP enabled
devices
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07753
APAR: IV07908
-------------
Abstract: MPLS VPN DETAILS REPORT FAILS TO LOAD
Description:The MPLS VPN Details Report (itnm_mpls_vpn_details.rptdesign)
fails to generate with the browser status shows as loading. The
NCIM temporary table space's datafile in Oracle was highly
increased from 100 MB to 33 GB while running the report. The
SQL query needs some improvement in order to display the report
correctly.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07908
APAR: IV07909
-------------
Abstract: NETSCREENIPROUTINGTABLE AGENT CRASHED DUE TO MEMORY LEAK
Description: NetScreenIproutingTable agent crashed due to memory leak and
mismatched number of ifDescr/ifSpeed in some of the NetScreen devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV07909
APAR: IV08027
-------------
Abstract: DEVICE SYSLOGS FILLED WITH AUTHENTICATION FAILURE MESSAGES
WHEN DISCOVERY RUN.
Description: Device syslogs are filled with Authentication Failure messages
when discovery is run,so the logs fill up quickly. Customer have 55
SNMP community strings configured in the domain.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08027
APAR: IV08192
-------------
Abstract: UNABLE TO CREATE A NETWORK VIEW USING A THE LINGERTIME FIELD
Description:The GUI Network View creator allows the user to select Filter on
a Chassis and the field lingerTime,
1. Create a Network View using Filter, on Chassis and field lingerTime some value
2. The view has 0 nodes, which is wrong when compared to what is
in model.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08192
APAR: IV08223
-------------
Abstract: REQUEST TO BACKPORT CHANGE FOR 3.9 FULLDISCOVERY.STCH TO 3.8 FUL
LDISCOVERY.STCH RELATED TO "ISPINGFINDERRUNNING"
Description:Full Discovery.stch to be backported to 3.8 FullDiscovery.stch in
regard to checking "isPingFinderRunning" as this would eliminate warnings.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08223
APAR: IV08858
-------------
Abstract: POLL DEFINITION SYNTAX ERROR WHILE NAME STARTS WITH NUMERIC
Description:Poller sometimes cannot work while poll definition name starts
with numeric or special character.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV08858
APAR: IV09223
-------------
Abstract: BUG IN REMOVEINFERREDCEDUPLICATES RESULTING IN MISSING DEVICES
WHEN CES ARE INFERRED
Description:When inferring CE devices, due to overlapping IP addresses, the
RemoveInferredCEDuplicates stitcher deleted valid entities in
order to replace them with inferred CE entities. The stitcher
needs some minor modifications so it doesn't do this.
The query assumes it is looking for "no access" main nodes but
doesn't specify that it is a main node and s o
can get a VLAN object or similar no access entity on a device
which does have SNMP access.
This causes the stitcher to later delete the device. The initial
query should also check the entity type.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09223
APAR: IV09257
-------------
Abstract: NO TOOLTIP VALUES SHOW WHEN AT LEAST ONE VALUE IS MISSING IN
NETWORK VIEW
Description:If the tooltips for a particular view contain a value (e.g.
"{custom.myValue}") that is not available for all entities, then
the tooltips for all those value will not be replaced. Instead,
the tooltip will still display the placeholder string, e.g {custom.myValue}.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09257
APAR: IV09258
-------------
Abstract: REQUIREMENT FOR HEARTBEAT KEEPALIVE BETWEEN NCP_CONFIG AND
DISCOVERY STATUS GUI
Description:The backend process ncp_config has been modified to send
keepalive heartbeat messages every 300 seconds.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09258
APAR: IV09454
-------------
Abstract: SNMP MIB BROWSER DOES NOT RESOLVE HOST NAME AGAINST NCIM DB
Description:When using the SNMP MIB Browser, and typing in a hostname in the
"Host" box, the name resolution is done by the Operating System,
not by network manger.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV09454
APAR: IV09740
-------------
Abstract: PERFORMANCE ISSUES WITH NETWORK VIEWS ACROSS A WIDE AREA
NETWORK
Description:network manger Network Views and Network View tree menu takes a long time to be
displayed when the when using a remote DB server i.e. being accessed across a wide area network from a local TIP/ITNM UI server.
APAR: IV10023
-------------
Abstract: THE VIEW NCPOLLDATA.POLLITEMVIEW DO NOT RETURN IP ADDRESS
Description:The view ncpolldata.pollItemView do not return ip address for
chassis and break reports because the a line from "createPollDataDb.sql" definition is not correct.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10023
APAR: IV10059
-------------
Abstract: STRUCTUREBROWSER HAS CHANGED TO TABLE MODE AFTER APPLYING ITNM
FP6.
Description: The structure browser in TIP has changed to table mode after
applying ITNM FP6.
It is stated in the release notes as follows: 5.4.3.
If you want the Structure Browser portlet to open in tree mode by default,set the property to 'tree' instead.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10059
APAR: IV10434
-------------
Abstract: MIS-TRANSLATION IN JAPANESE VERSION OF THE DISCOVERY WIZARD WITH
REGARDS TO END NODE DISCOVERY
Description: On the End Node discovery Wizard page that asks about
End Node discovery, the Japanese translation suggests that the
end node filter will not be applied.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10434
APAR: IV10815
-------------
Abstract: NCP_NCOGATE CORE AT CNCOCONNECTION::READERMAINLOOP: LOOP HAS
BEEN TERMINATED
Description: The ncp_ncogate process is coring.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV10815
APAR: IV11080
-------------
Abstract: LINGERTIME IS NOT CONSISTENT BETWEEN MODEL AND NCIM
Description: LingerTime is not consistent between Model and NCIM.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11080
APAR: IV11178
-------------
Abstract: EVENT GATEWAY FAILS TO CLOSE CONNECTION ON BACKUP OBJECTSERVER
WHEN FAILING BACK.
Description: The Event Gateway opens two connections to an ObjectServer.
When the gateway is connected to the Backup ObjectServer and the
Primary becomes available again, the gateway fails back to the
Primary ObjectServer.
APAR: IV11270
-------------
Abstract: CDP AGENT RUNS INTO INFINITE LOOP - CAUSING OUT OF MEMORY
CONDITION
Description: Customer discovers a device that is causing the CDP agent to go
into a loop until it runs out of memory.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11270
APAR: IV11271
-------------
Abstract: 4 CISCO 3750 STACKED SWITCHES NOT BEING DISPLAYED AS 1.
Description: 4 Cisco 3750 stacked switches with 208 ports (54x4) should
appear as a single entity.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11271
APAR: IV11724
-------------
Abstract: NETWORK VIEW WITH IP FILTER RETURNS ZERO NODES
http://www-01.ibm.com/support/docview.wss?uid=swg1IV11724
APAR: IV12417
-------------
Abstract: ITNM 3.9 CREATE IP FILTER VIEW DOCUMENTATION
Description: When performing the steps in the documentation ->
http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/index.jsp
?topic=%2Fcom.ibm.networkmanagerip.doc_3.9%2Fitnm%2Fip%2Fwip%2Fadmin%2Fr
eference%2Fnmip_adm_ipfiltersyntax.html. The result is always 0 devices in the network view.
Using OQL it is confirmed that the result in our replication should be n number of devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12417
APAR: IV12650
-------------
Abstract: CISCODEVICETELNET AGENT FAILS TO GET THE TOPOLOGY INFORMATION
FROM CISCO 2800 SERIES BY 'SHOW MAC-ADDRESS-TABLE'
Description: Cisco 2800 series routers FDB data can only find by telnet agent .
The supported 'show mac-address table' outputs: # show mac-address-table
Dynamic Address Count: 20 Secure Address.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12650
APAR: IV12759
-------------
Abstract: Disco Config and Status pages share the same domain session vari
able.
Description: Changing the domain in one of the pages, affects the other.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12759
APAR: IV12850
-------------
Abstract: ITNM KNP AGENT FRENCH MESSAGE TRANSLATION ERROR
Description: Status in the availability view in FRENCH in error.
In the monitoring view, the status is bad:it indicates EN
FONCTION while the status is Down, and HORS FONCTION while the status is UP.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12850
APAR: IV12927
-------------
Abstract: REDUCING VERBOSITY OF NCP_POLLER.SNMPPOLLER.<DOMAIN>.TRACE
CONTAINS LOT OF REPEATATIVE MESSAGES CAUSES LOGFILE TO GROW HUGE
Description: Customer need to reduce the volume of logging in
ncp_poller. SnmpPoller.<domain>.trace file as it causes the file to grow huge.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV12927
APAR: IV13225
-------------
Abstract: DISCOVERYUPDATEMODE IS 0 AND LINGERTIME DESCREASED DURING
PARTIAL REDISCOVERY
Description: In SendTopologyToModel.stch, disco sends the request of update
to model.config for DiscoveryUpdateMode first, and sends the
request of Topology data update request to model at the end of stitcher.
However in the model side, it randomly got the message of
Topology Data update earlier than the message of
DiscoveryUpdateMode update in model.config. It turned out to use
the un-updated DiscoveryUpdateMode 0 and decided the Lingertime
to be checked.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13225
APAR: IV13278
-------------
Abstract: IN ITNM 3.8 NETWORK HEALTH VIEW, WHENEVER THERE IS A CLEAR SEVER
ITY FOR ANY DISCOVERED DEVICE, IT SHOWS WITH THE COLOR GREEN.
Description: In ITNM 3.8 Network Health View, whenever there is a clear
severity for any discovered device, it shows with the color
green, whereas in the Left Hand Side panel of Network view (Tree
View) => Max column, we don't see any green color icon (Actually
it shows no icon).
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13278
APAR: IV13415
-------------
Abstract: NETSCREENINTERFACE AGENT CORE NOT HANDLING CONDITION PROPERLY
Description: The NetScreenInterface agent was not handling condition properly.
The device in question was returning empty nsVpnMonTunnelState list and the agent assume that the device will always return something.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13415
APAR: IV13837
-------------
Abstract: NCMONITOR TABLES IS NEVER PURGE
Description: NCMONITOR tables got never purged.Snmptarget contains all
targets since the first discovery.Need to run:
"delete from ncpolldata.monitoredInstance where entityId not in
((select entityId from ncim.entity));"
"delete from ncpolldata.monitoredInstance where entityId not in
((select entityId from ncim.interface));"
in adition to
http://www-01.ibm.com/support/docview.wss?uid=swg1IV13837
APAR: IV14221
-------------
Abstract: THE DOMAIN_DROP.PL SCRIPT IS SUPPOSED TO INCREMENTALLY DELETE
ENTITIES FROM A DOMAIN.
Description: When deleting directly from the domainMgr table or deleting all
entities in a single command, the level of cascaded deletions
that are performed can result in a transaction that is too large
for the database to handle or is simply too slow. The
domain_drop.pl script resolves this by incrementally deleting
batches of entities from the domain before deleting the domain
itself, but this mechanism does not currently work. The entities
are deleted only at the end of the script, when the domain
itself is removed from the domainMgr table.This defeats the
purpose of the script, and can fail on very large topologies.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV14221
APAR: IV14476
-------------
Abstract: MPLS VPN VIEWS DISPLAY INCORRECTLY IN ITNM 3.8 FP6
Description: The MPLS VPN displays too many devices,there by removing
them from MPLS core cloud and hence creating an empty MPLS core cloud.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV14476
APAR: IV15667
-------------
Abstract: FIND IN NETWORK VIEWS STOPS WORKING
Description: Right Hand Tool for Events in AEL "Find in Network
Views" stops working after a while.
The test fix introduced code that encounters a defect in the DB2 JDBC driver.
This APAR is raised to record the changes required to mitigate
for that defect in the DB2 JDBC driver.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV15667
APAR: IV15884
-------------
Abstract: ITNM POLLER NOT CLEARING EVENTS RAISED BY A PREVIOUS INSTANCE.
Description: ITNM poller not clearing events raised by a previous instance.
Existing active events need to be read on poller start up.
ActiveEvent table has been updated in NcPollerSchema.cfg file.
If the NCHOME/etc/precision/NcPollerSchema.cfg file has been customized before,
then the existing file should be merged with NCHOME/etc/precision/default/NcPollerSchema.cfg with the appropriate value set.
APAR: IV16149
-------------
Abstract: wrong subnet and netmask for Chassis IpAddress
Description: The current issue is that the device has wrong information.
It seems that when the discovery runs the first time, the
default network is /24 for all the devices and after this netmask is
never updated according to the SNMP information recovered when ITNM
build the devices and its interfaces. First the default value of /24 is
misleading. The default should be /32 (= scope of a single
host) and secondly this netmask (/32) should be updated according to the SNMP info.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV16149
APAR: IV16616
-------------
Abstract: DATA IMPORT OF VIEWS IS FAILING BECAUSE OF INVALID
ENTITYNAME(S) IN THE NCIM.ENTITYNAMECACHE TABLE.
Description: Data import of views is failing because of invalid
entityName(s) in the ncim.entityNameCache table. Export from
old system worked OK. Also the import of the views fails if the
itnmExportedEntityNameCache.dat file is empty.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV16616
APAR: IV16617
-------------
Abstract: network manger 3.8 FP5 NCP_CTRL
Description: The ncp_ctrl process has a master slave mode which allows it to
run processes on remote servers. The function is independent of the
remote pollers and can start any network manger process and I don't there fore see it as part of the question around support for remote pollers.
When testing on site we saw that while the slave ncp_ctrl process did indeed start the remote
process, however it failed to stop it again when the master ncp_ctrl was stopped.
APAR: IV16886
-------------
Abstract: MAINTENANCESTARTTIME AND MAINTENANCEENDTIME IS NULL IN MANAGED STATUS TABLE. (APAR=IV16886)
Description: When we keeping any device in maintenance mode then no data is
saved in the managedstatus table like MaintenanceStartTime and MaintenanceEndTime, its always NULL but the changetime column is being filled with correct date-time.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV16886
APAR: IV18264
-------------
Abstract: WHEN MULTIPLE POLLERS ARE RUNNING, ALL POLLERS TRY TO PRUNE DATA
RESULTING IN DEADLOCKS
Description: We have noticed that when using multiple pollers all poller
instances try to launch the pruning process resulting in deadlocks on the pollData table and resulting in warning messages in the poller log.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV18264
APAR: IV18992
-------------
Abstract: Changing the locale settings from en_US.UTF-8 to RU_RU.UTF.8
then save GUI and start Discovery generate error in disco log.
Description: On network manger AIX install when
customer is changing the locale settings from en_US.UTF-8 to
RU_RU.UTF-8 then saves the discovery settings from GUI and start
FullDiscovery, ncp_disco.log reports :
2012-02-10T16:17:21: Warning: W-RIV-002-140: [1t]xxxx.cc(1563)The database insert was invalid.
Column and values lists different lengths, can not construct record from
insert. Column list length: 35 value list length: 36.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV18992
APAR: IV19168
-------------
Abstract: LINGERTIME VALUE DISPLAY ACCIDENTALLY REMOVED FROM DEVICE STRUCT
URE VIEW AFTER APPLY FP1 (APAR IN ERROR IS IV08192)
Description: This APAR is created as AE/MDV APAR with "MDVREGR" class.
LingerTime value was left off Device Structure Display in 3.9 FP1
http://www-01.ibm.com/support/docview.wss?uid=swg1IV19168
APAR: IV19726
-------------
Abstract: ITM AGENT IS SLOW TRANSFERRING DATA FROM NCPOLLDATA TO TDW
Description: ITM agent is very slow in moving data from local db(NCPOLLDATA)
to Tivoli Data Warehouse(TDW) due to inefficient queries under getPolldata.pl
http://www-01.ibm.com/support/docview.wss?uid=swg1IV19726
APAR: IV19728
-------------
Abstract: POLLER STORING TOO MANY ROWS IN NCPOLLDATA FOR PINGS
Description: Poller stores two rows for a given polled instance (e.g. ICMP).
This request is to reduce number of rows to be one(1) - so that
we store both polled time and response time under single row.
The change will decrease number of rows we store in NCPOLLDATA
and at the same time reduces overhead on Poller.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV19728
APAR: IV20184
-------------
Abstract: SNMP HELPER(NCP_DH_SNMP) DOES NOT PROCESS OTHER GENERIC
COMMUNITY STRINGS WHEN PREVIOUSLY SUCCEEDED ONE FAILS
Description: Snmp helper fails to try other community strings when previously
succeeded string fails - resulting the device in 'NOSNMPAcecess'
and/or duplicate nodes if EntityName doesn't match.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV20184
APAR: IV20360
-------------
Abstract: $PRECISIION_HOME/PRODUCTS/TNM/BIN/ITNM_POLLDATA_PRUNINGSCRIPT T
AKES 3 DAYS TO PRUNE POLLDATA WHEN IT IS LARGE.
Description: PrunePollData uses JOINs which cause Informix to delete entries very slowly from
poll Data. To simplify the deletes,we need to make a schema change.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV20360
APAR: IV20889
-------------
Abstract: SOME MPLS TE PATHS ARE NOT VISUALISED CORRECTLY
Description: Some MPLS paths fail to be created where MPLS TE Tunnel Hop
devices are a mixture of Layer 2 and Layer 3 devices.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV20889
APAR: IV21588
-------------
Abstract: ALLOW SYNCHRONISATION OF BATCH TIMES BETWEEN MULTIPLE POLLERS TO CONTROL BANDWIDTH
Description: This chance is part of the STIME crit sit and tracked under the
following:Add new parameter for the VSAT poller to explicitly select the
TIME of the first poll. The requirement is that when operating multiple pollers so monitor a
satellite link it must by possible to synchronize the
batch times of those pollers. So that the bandwidth can be
controlled and thus prevent costs being incurred by exceeding
the bandwidth limits on the link.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV21588
APAR: IV22262
-------------
Abstract: NETVIEW DATA EXTRACTION DOES NOT WORK
Description: When the customer runs the exportNVData.sh script according to
instructions, it fails due to missing the Itnm_Unzip.class file.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22262
APAR: IV22788
-------------
Abstract: UNMANAGE/MANAGE ACTION CAUSES BACKUP POLLER TO POLL DEVICE.
Description: In a failover environment with a Primary and Backup running,
with the Primary domain healthy and acting primary, if the user unmanages,
then manages a device, the backup poller will begin polling that device, and
raising duplicate events.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22788
APAR: IV22933
-------------
Abstract: DISCO IP MALFORM
Description: When disco encounter Ip addresses malformed (If the IP Address
is not valid (e.g. 5 octets) or empty) it crash.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22933
APAR: IV22998
-------------
Abstract: NCP_CTRL FAILS TO PROCESS SIGCHLDS PROPERLY RESULTING IN KILLING
WRONG PROCESSES
Description: The problem was observed on AIX only
When ncp_ctrl receives SIGCHLD, it fails to process properly
and tries to stop wrong process.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV22998
APAR: IV23046
-------------
Abstract: STITCHER LANGUAGE OPERATOR ISSUE
Description: ExecuteSQL on a column containing hyphen/minus returns NULL.
The commands SQLData / PrepareSQL / ExecuteSQL return NULL if
the column contains - (hyphen) as value.
APAR: IV23863
-------------
Abstract: COLLECTOR ENDED SUDDENLY AT THE END OF ITS WORK DURING
DISCOVERY.
Description: Collector ended suddenly at the end of its work during
discovery. No additional information available at this time.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV23863
APAR: IV24388
-------------
Abstract: COREBUILDER 3COM SWITCH AGENT FAILED DURING DISCOVERY DUE
TO FATAL ERROR.
Description: The agent is terminated due to the following error:
Error: An unrecoverable error occurred. Please contact IBM
Support.
Fatal Error: Duplicate Object Upon Insertion found in xxxxxx.cc at line 1902
Application terminating due to error.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24388
APAR: IV24427
-------------
Abstract: EVENT SYNCHRONIZATION BETWEEN THE EVENTS SHOW IN OMNIBUS AND THE
POLLER
Description: Restart of the ncp_poller process the new instance of the
poller will not clear any outstanding events which had been raised by the
previous instance.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24427
APAR: IV24695
-------------
Abstract: AE IV00446 FIX COMPLETION->OS AGENT FAILS ON 3.8 FP5 AND DISCO
FAILS
Description:
In adition to APAR IV00446 which partially solves the isuse:
http://www-01.ibm.com/support/docview.wss?uid=swg1IV00446
disco still dies
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24695
APAR: IV24795
-------------
Abstract: UPDATE JAVA CERTIFICATE IN
/EXPORT/SRC/NCP/NCP_GUI/TOPOVIZ/APPLETSIGNING
Description: update Java certificate in
/export/src/ncp/ncp_GUI/Topoviz/appletsigning.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24795
APAR: IV24844
-------------
Abstract: ncp_perl core dump
Description: Symptoms:
ncp_perl is core dumping in a similar manner to IV00076.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24844
APAR: IV24939
-------------
Abstract: NEXUSCONTAINERS STITCHER DOESN'T WORK PROPERLY WHEN
DEALS WITH MULTIPLE CISCO NEXUS DEVICES
Description: When multiple Cisco Nexus devices are present into domain scope,
the NexusContainers stitcher add the correct containment only
for the first discovered device
As 'm_Name' column from working Entities table is unique, further
containment inserts will fail.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24939
APAR: IV24945
-------------
Abstract: PROCESSES CORE DUMP WHEN TRACE FILE ROTATION IS ENABLED AND THE
FILE REACHES 2GB
Description: When trace file rotate for the process, it core dump.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV24945
APAR: IV25131
-------------
Abstract: RCA FAILS TO SUPPRESS EVENTS FROM THE CHASSIS IP WHEN THE GRAPH
ENDS ON AN INTERFACE WITH THE SAME IP.
Description:
Isolated-Suppression fails to suppress events from the chassis
when the graph though the network terminates on an interface with the same
IP.In the user case, the interface that is used to identify the
chassis is contained within an VLAN. Although the VLAN is
subsequently contained within the chassis, it is also isolated
within the chassis because the chassis device is not an
IP-FORWARDING device. So although connectivity extends from the
interface to the VLAN, the path is not continuous up to the
chassis entity.
Therefore when RCA encounters events from the Chassis entity, it fails to
complete a continuous path from the polling station all
the way to the chassis and does not mark the event as a symptom.
Action:
1.Modify the Discovery stitcher code so that the interface
is upwardly connected to the VLAN.
2. Modify the RCA code so that when the Isolated-Suppression
algorithm encounters an interface on the path that has the same
IP address as the chassis, it looks for events on the chassis
too and suppresses any events it finds on the chassis.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV25131
APAR: IV25842
-------------
Abstract: STACKED DEVICES NOT PROPERLY CONNECTED CAUSING PROBLEMS FOR
POLLER
Description: After installing fix for IV11271, customer found that the
connectivity between the stacked hubs was incorrect, all
devices were showing EntityType=1 and the same m_UniqueAddress.
So we were not properly polling all stacked entities
http://www-01.ibm.com/support/docview.wss?uid=swg1IV25842
APAR: IV26368
-------------
Abstract: RESOLVE LINGERTIME ISSUE WITH PERMANENTLY UNMANAGED DEVICES
Description: If devices are set to the Permanently Unmanaged state (status=2
or 3) in a discovery stitcher then Model never decrements the
LingerTime so that those devices never linger out.
APAR: IV26410
-------------
Abstract:DATABASE LOCKING IN ITNM POLLER
Description:Under specific conditions a lock can be held on DB2 tables that
prevents other applications acheiving a similar lock.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26410
APAR: IV26715
-------------
Abstract: FALSE PING FAIL EVENTS GENERATED WHEN NTP CLOCK ADJUSTMENTS ARE MADE.
Description: Very fast responses can appear to the poller to
arrive before the request is sent, resulting in ping fail events
where no such outage exists.
When network manger is processing very fast ping responses (in the order
of millisecs) occasionally an anomaly occurs with the
timestamps used for send/receive packets. The effect of this
currently is that the rtt appears negative and a timeout is
incorrectly triggered.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26715
APAR: IV26842
-------------
Abstract: WRONG FORMAT OF TIME IN EXCEL REPORT.
Description: When a report is exported as Excel file, then format of date in
the exported file is "yyyy-m-d hh:ss:mm", though it should be "yyyy-m-d
hh:mm:ss". *ss* and *mm* should be reversed.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV26842
APAR: IV27657
-------------
Abstract: SQL QUERIES FROM THE STITCHER LANGUAGE FAIL FOLLOWING A DATABASE RECONNECTION.
Description:The customised stitcher, ReplaceDisplayLabel, directly accesses
an external database to retrieve the info used for the displaylabel. That
data is formatted and added to the scratchTopology data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV27657
APAR: IV27953
-------------
Abstract: NCP_MIB DOES NOT PROPERLY PARSE MODULE DEFINITION WITH MORE THAN
2 ITEMS
Description: The ncp_mib does not load the mib module definition with more
than 2 items
For an example in PF-GS_MIB-v4_0.mib there is a line with 2 items
identifier ::= { enterprises anritsu(1151) 2 1 7 }
which is not correctly parsed by ncp_mib.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV27953
APAR: IV28101
-------------
Abstract: NOSUCHNAME EVENTS GENERATED FOR ENTITIES THAT WERE POLLING WITHOUT ERROR.
Description: Configure SNMP Link State poll policy *with* interface
coping.(Policies without interface scopes will not trigger this
APAR).Failover to the Backup domain by stopping the entire Primary domain.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV28101
APAR: IV30474
-------------
Abstract: CDPLAYER STITCHER FAILS IF REMOTEIFNAME IS NULL
Description: The CDPlayer stitcher fails on the remote device that has an
interface to a null interface name.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30474
APAR: IV30624
-------------
Abstract: ITNM'S MODEL PROCESS SHOULD HONOUR LINGERTIME VALUES SET BY THE ITNM DISCO PROCESS.
Description: Model ignores LingerTime values set by Disco.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30624
APAR: IV30706
-------------
Abstract: TRANSLATION OF TIME PERIOD READS "PAST 1 YEAR" BUT CORRECT
TRANSLATION SHOULD BE "YEAR TO DATE"
Description: The default network manger reports contain a translation error
for one of the values presented via the report period drop down. In the
report period drop down, the Japanese text translates as "past 1 year" but
the time period in the report is from the beginning of the current year.
The expectation is that the report shows data from January 1st
of the current year. So the report is correct according to the expectated
result.
What is wrong is the value in the drop down list for the period.
Instead of reading "past 1 year" it should read "year
to date". The meaning is different. Past 1 year implies
a full year worth of data going back in time from today's date.
Year to date implies all data from the beginning of the current year.
NOTE: The results of the default report is correct. It is the
translation for year to date in the list of options in the drop
down that needs correcting.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30706
APAR: IV30911
-------------
Abstract: BY DEFAULT LOG FILES CAN GROW UNLIMITED IN SIZE. IN ADDITION
THE DOCUMENTATION SAYS THE DEFAULT LIMIT IS 102400 BYTES.
Description: By default, there is no limit to the size logs can grow
to. In addition the documentation needs to be updated to say
the default limit is 1GB and add a note on estimating log space
for planning.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV30911
APAR: IV31296
-------------
Abstract: ASSOCADDRESS AGENT TO USE IPADENTADDR VALUE INSTEAD OF THE INDEX FOR THE IPADDRTABLE ENTRY.
Description: AssocAddress Agent Symptom: The AssocAddress agent use the index of the entry in ipAddrTable and according to RFC1213,
the index of ipAddrTable should be ipAdEntAddr.However, in some Alteon ADC and VADC
devices, the index of ipAddrTable is having a different value than ipAdEntAddr, i.e. ipAdEntAddr
with index IP.IP.IP.112 is having IP.IP6.IP.114 as it's value: ipAdEntAddr.IP.IP.IP.112: IP.IP.IP.114
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31296
APAR: IV31587
-------------
Abstract: SNMP TIMEOUT
Description: For every first SNMP query to determinate if the device responds
to SNMP, the timeout configfured is not used.
E.g:
Timeout : 3000 ms
Retries : 2.
The process does not use wait 3 seconds to start the first retry
but it reties after 1 sec of timeout.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV31587
APAR: IV32418
-------------
Abstract: INFORMIX NCPOLLDATA.KNP_POLL_DATA_COLLECTION.POLLTIME ALWAYS SHOWS NULL ACCESSED BY NCP_OQL SERVICE NCIM
Description: ncpolldata.knp_poll_data_collection.POLLTIME in informix NCIM always shows NULL while accessed by ncp_oql service ncim interface.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV32418
APAR: IV33079
-------------
Abstract: NCP_DISCO CORE DUMPS WHILE EXITING IF NATTIMER STITCHER(RUNS
EVERY HOUR OUT-OF-THE-BOX) TRIGGERED DURING SAMETIME.
Description: If the disco process is getting recycled (stopped and restarted)
on top of the hour say 10am, and the NATTimer stitcher which
runs every hour out-of-the-box is triggered at same time will
cause Disco process to core while exiting.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33079
APAR: IV33114
-------------
Abstract: MODEL MANAGED STATUS WORK
Description: Managed status state transitions and propagation from chassis to subcomponents must follow a number of rules (as documented in the ITNM best practices guide.)
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33114
APAR: IV33118
-------------
Abstract: REMOTE POLLERS ARE NOT STOPPING REMOTELY
Description: During the stop of ncp_ctrl all the local children are
stopped and the remote processes are stopped via the ncp_ctrl slave but not
remote poller.
APAR: IV33478
-------------
Abstract: RECREATEANDSENDTOPOLOGY.STCH IS MISSING THE CALL TO SONMPLAYER
Description: During a rediscovery the SONMPLayer database is not
included in the list of arguments to the Merge Layers stitcher
in RecreateAndSendTopology.stch
leading to incorrect connectivity for devices advertising data via SONMP
such as Nortel switches.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV33478
APAR: IV38462
-------------
Abstract: SCOPE.SPECIAL EXTENDED TO CHASSIS AND INTERFACES.
Description: "scope special" is an existing feature we extend to chassis and
interfaces.Please see following
RFE..http://www.ibm.com/developerworks/rfe/execute?use_case=viewRfe&CR_ID=31587
Changes to the scope.special table.
The following link describes the existing “special” table from the scope database :
http://publib.boulder.ibm.com/infocenter/tivihelp/v8r1/topic/com.ibm.networkmanagerip.doc_3.8/itnm/ip/wip/disco/reference/nmip_dsc_dsc_scope_db_schema_special_table.html
Following new data fields have been added in
NCHOME/etc/precision/default/DiscoSchema.cfg.
Column name Constraints Data type Description
m_Identifier Text Optional identifier for tracking
m_Priority int Optional priority used if used if there are multiple matches,
in which case the scope.special entry with the highest priority will be selected.
m_NonPingable int If set to 1 then the address will be selected even if could not be pinged
m_AdminInterface int type boolean Does this apply to interface entities Note: m_IsManagement is for chassis
m_ExtraInfo object type vblist Optional fields with which the arget entity could be enriched
If the NCHOME/etc/precision/DiscoSchema.cfg has been customized before, then
the existing file should be merged with
NCHOME/etc/precision/default/DiscoSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV38462
APAR: IV44536
-------------
Abstract: EMPTY DATA IN TARGET SERVER AFTER MIGRATION (FROM ITNM 3.8.FP7TO ITNM 3.9.0)
Description: There is no error when run nmImport in target server. After run
nmImport, the network view get migrate to target server but 0 node. When
checking in databases, there is empty record for entiydata, chassis.
The export scripts require m_EncryptPasswords to be the second column in
the insert into config.settings insert.
If the NCHOME/etc/precision/ConfigSchema.cfg has been customized before,
then the existing file should be merged with N
NCHOME/etc/precision/default/ConfigSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44536
APAR: IV44547
-------------
Abstract: INCORRECT ICON IN NETWORK/HOPVIEW FOR FIREWALL DEVICE
Description: Discovery against Juniper Netscreen device and noticed that in
hopview it was not represented as firewall icon. topoviz.properties in
TIPHOME/profiles/TIPProfile/etc/tnm/ is missing this entry:
topoviz.image.Firewall=firewall.svg
Copy new value set into
TIPHOME/profiles/TIPProfile/etc/tnm/topoviz.properties.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44547
APAR: IV44549
-------------
Abstract: THE NCP_NCOGATE PROCESS NEEDS TO BE ABLE TO OPTIONALLY UPDATE AN
EVENT WHEN THE TOPOLOGY LOOKUP FAILED.
Description: The problem it addresses is the fact that the 3.8 gateway will
simply discard events that fail the topology lookup. This means that the
Impact policy which the customer has chained off the gateway's update will
never be triggered because the event is not updated.
Added the following to the gateway configuration file:
////////////////////////////////////////////////////////////////////////////////
// This is optional for events moving from ITNM to Omnibus that failed in the
// topology look up. An example of when you might use this is to update a flag
// in the event to indicate that ITNM has finished processing the event. This
// flag could then be used by an Impact policy to initiate further processing
// of the event.
//
// Note that after processing the EventFilter defined in config.ncp2nco will be
// applied.
//
create table config.topoFail
(
EventFieldMap object type vblist
);
// insert into config.topoFail
// (
// EventFieldMap
// )
// values
// (
// {
// NmosObjInst = 0,
// NmosEntityId = 0,
// NmosSerial = '',
// NmosCauseType = "eval(int, '$CAUSEUNKNOWN')"
// }
// );
If the NCHOME/etc/precision/NcoGateSchema.cfg has been customized before,
then the existing file should be merged with
NCHOME/etc/precision/default/NcoGateSchema.cfg with the appropriate value set.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV44549
APAR: IV47466
-------------
Abstract:UPDATE THE VERSION OF GSKIT USED BY ITNM 3.8 &3.9
Description: ITNM version 3.9 Fp3 and 3.8 FP7 upgraded with GSKIT 8.0.14.23.
http://www-01.ibm.com/support/docview.wss?uid=swg1IV47466
APAR: IZ89794
-------------
Abstract: SINGLE QUOTES REQUIRED WHEN USING LITERALS IN POLLING POLICY,
HOWEVER THE GUI REPLACES QUOTES WITH ', BREAKING POLICY.
Description: When creating a Poll Definition involving a literal string, the
literal must be placed within single quotes. If you don't place
the string in quotes,the poller throws the error "error in
template" ... I believe this is expected.
However if you quote the string, it appears the quotes are
replaced by the string "'". This happens if you change
between the tabs (eg "Trigger Threshold" to "Clear Threshold"
and back to "Trigger Threshold") while creating a new poll
definition. It also happens when you save the poll definition
and then bring that poll definition back up for editing. If you
save the definition and edit a 3rd time, the "&" in "'" is
replaced by "&". And this replacement of the "&" will go on
continuously.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ89794
APAR: IZ93148
-------------
Abstract: SINGLE QUOTES IN LDAP GROUP NAMES CAUSE AUTHENTICATION ERRORS IN
NETWORK VIEWS
Description: A user logs into TIP and attempts to access
the ITNM v3.8 Network Views tool. The user gets a error message that says
"unable to access database" even though the user has the appropriate
permissions.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ93148
APAR: IZ95110
-------------
Abstract: INCORRECT CONTAINMENT BUILDING FOR MANAGEMENT PORTS ON CISCO XR
IOS SOFTWARE DEVICES.
Description: Cisco XR IOS software devices only.
ContainResolvablePortEntities.stch does not have associated logic to handle
Management Ports that are listed under Entity-Mib and to integrate with
IF-MIB interface data.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ95110
APAR: IZ95608
-------------
Abstract: NCP_POLLER DOES NOT HONOUR GETNEXT THROTTLING PARAMETERS
Description: GetNextSlowDown, GetNextBoundary, and GeneralSlowDown settings
don't currently have any effect. This APAR is to enable these
features.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ95608
APAR: IZ96931
-------------
Abstract: VIRTUAL DOMAIN CONNECTION BETWEEN PRIMARY AND BACKUP NOT ALWAYS
CORRECTLY
Description: virtual domain connection between primary and backup ITNM
servers on different machines does not always restored correctly.
In a ITNM failover setup with primary and backup on two
machines, after the virtual domain processes had connected, if
there occurs an connection issue, Virtual domain should recover
from this once the connection can be re-established, but this
did not always happen. So when there is a tcp connection between
the two virtual domain processes and the tcp connection is rese t
due to firewall/network issues, intermittently the system does
not reconnect properly which will result in the backup ITNM not
being updated.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ96931
APAR: IZ97548
-------------
Abstract: WHEN A INTERFACE IS EXCLUDED, AN ALERT IS STILL RAISED WHEN POLL
FAILS
Description: When using a post-discovery filter to eliminate specific
interface types, those interfaces are not included in model or
ncim as expected. However, when a poll without an interface
filter is run against that device - per the recommended
configuration - the poll result is not discarded, thus, if the
poll fails for a particular interface, an alert will be raised.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ97548
APAR: IZ98723
-------------
Abstract: DISCREPANCY ON EVENTMAP FOR NMOS PINGFAIL EVENTID
Description: NcoGateSchema.cfg and NcoGateInserts.cfg has discrepancy of the
eventMap for eventId 'NmosPingFail'.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ98723
APAR: IZ99325
-------------
Abstract: ACTIVE POLLING POLICY REMAINS ON THE BACKUP NCMONITOR DB AFTER
DELETED ON THE PRIMARY
Description: While deleting active polling policy on the primary, the
MonitorPolicies.<DomainName>.xml synchronized OK on the backup,
but not synchronized in backup ncmonitor database, where
the active polling policy remains and could generate poll data
if primary server down.
http://www-01.ibm.com/support/docview.wss?uid=swg1IZ99325
Prerequisites
IBM Tivoli Network Manager IP V3.8 must be installed before applying the Fix Pack..
IBM Tivoli Network Manager IP Edition 3.8 Fix Pack 7 is available as a separate install for Solaris, AIX, Windows and Linux.
This Fix Pack installer is cumulative and can be applied to any previous
maintenance level of Tivoli Network Manager IP V3.8. Some of the steps in this document may
have already been done if you applied a previous Fix Pack and don't need to be reapplied.
Ensure that there is approximately 1 gigabyte of free space on the drive
on which the product was installed
Note: When using the Windows command line, preface and suffix environment
variables with the percentage sign %, and replace each forward slash (/)
with a backslash (\) in directory paths.
For example, on Windows systems, $NCHOME is %NCHOME%.
While applying a FixPack, GUI properties file in $NCHOME/etc/precision/default and $TIPHOME/profiles/TIPProfile/etc/tnm/default will be overwritten. Back up these files before applying the fix pack and merge them with customized ones after applying the fix pack. See readme .txt file for detail.
Installation Instructions
Full details on how to install and perform post installation for this fixpack can be found in the INSTALL file which is downloadable from the link below...
Contacting IBM Support
Please use the IBM Tivoli Support website:
http://www-01.ibm.com/software/support/exchangeinfo.html
Prerequisites
IBM Tivoli Network Manager IP V3.8 must be installed before applying the Fix Pack..
IBM Tivoli Network Manager IP Edition 3.8 Fix Pack 7 is available as a separate install for Solaris, AIX, Windows and Linux.
This Fix Pack installer is cumulative and can be applied to any previous maintenance level of Tivoli Network Manager IP V3.8. Some of the steps in this document may have already been done if you applied a previous Fix Pack and don't need to be reapplied.
Ensure that there is approximately 1 gigabyte of free space on the drive on which the product was installed
Note: When using the Windows command line, preface and suffix environment
variables with the percentage sign %, and replace each forward slash (/)
with a backslash (\) in directory paths.
For example, on Windows systems, $NCHOME is %NCHOME%.
See 3.8.0_INSTALL_FP0007.txt file for detail pre-req information.
URL | LANGUAGE | SIZE(Bytes) |
---|---|---|
3.8.0_README_FP0007 | US English | 83631 |
3.8.0_INSTALL_FP0007 | US English | 37655 |
3.8.0_INSTALL_NLS_FP0007 | US English | 103248 |
3.8.0_README_NLS_FP0007 | US English | 136985 |
Download | RELEASE DATE | LANGUAGE | SIZE(Bytes) | Download Options |
---|---|---|---|---|
3.8.0-TIV-ITNMIP-AIX-FP0007 | 13 Sep 13 | US English | 1367078175 | HTTP |
3.8.0-TIV-ITNMIP-Linux-FP0007 | 13 Sep 13 | US English | 1262573000 | HTTP |
3.8.0-TIV-ITNMIP-Solaris-FP0007 | 13 Sep 13 | US English | 1213985792 | HTTP |
3.8.0-TIV-ITNMIP-Windows-FP0007 | 13 Sep 13 | US English | 1075939399 | HTTP |
3.8.0-TIV-ITNMIP-zLinux-FP0007 | 13 Sep 13 | US English | 1218891477 | HTTP |
IZ47811, IZ65371, IZ77983, IZ78381, IZ80005, IZ81036, IZ84482, IZ85337, IZ85441, IZ86011, IZ86201, IZ86283, IZ87272, IZ87320, IZ87567, IZ89174, IZ89799, IZ89825, IZ89953, IZ89967, IZ90062, IZ90247, IZ90525, IZ91006, IZ91113, IZ91113, IZ92126, IZ92139, IZ92508, IZ92509, IZ93029, IZ94332, IZ94405, IZ94550, IZ94642, IZ94749, IZ95507, IZ95646, IZ95782, IZ96016, IZ96220, IZ96242, IZ96285, IZ96537, IZ96680, IZ53996, IZ96937, IZ97314, IZ97348, IZ97974, IZ98083, IZ98663, IZ98726, IZ98798, IZ99039, IZ99288, IZ99474, IZ99578, IZ99855, IV00076, IV00446, IV00672, IV00808, IV00923, IV00925, IV00926, IV01100, IV02909, IZ68880, IZ73532, IZ74467, IZ76369, IZ77010, IZ77691, IZ77702, IZ77758, IZ78138, IZ78155, IZ78279, IZ78285, IZ79681, IZ80102, IZ80897, IZ80898, IZ81206, IZ81475, IZ82383, IZ82822, IZ82837, IZ83476, IZ83740, IZ83742, IZ84425, IZ85090, IZ85113, IZ85321, IZ85606, IZ85722, IZ85782, IZ86283, IZ86825, IZ86871, IZ87135, IZ87165, IZ87258, IZ87584, IZ87910, IZ88605, IZ88853, IZ88972, IZ89301, IZ89818, IZ92174, IZ92183, IZ92189, IZ92191, IZ92193, IZ92196, IZ92197, IZ92199, IZ92484, IZ84399, IZ85921, IZ73447, IZ61115, IZ64903, IZ56490, IZ67528, IZ68078, IZ62735, IZ68893, IZ73448, IZ73449, IZ73458, IZ73452, IZ73464, IZ53043, IZ56768, IZ60584, IZ62664, IZ63700, IZ73469, IZ63085, IZ73470, IZ64092, IZ64844, IZ65338, IZ65525, IZ65569, IZ73472, IZ65302, IZ65516, IZ66759, IZ58862, IZ46979, IZ62710, IZ66357, IZ62536, IZ62246, IZ40084, IZ41729, IZ42752, IZ42959, IZ44508, IZ45657, IZ45660, IZ46682, IZ47606, IZ47811, IZ48222, IZ48538, IZ48657, IZ50360, IZ50824, IZ51286, IZ51645, IZ52419, IZ52651, IZ52691, IZ52872, IZ53557, IZ53563, IZ53873, IZ53996, IZ54578, IZ55343, IZ55385, IZ55391, IZ55393, IZ55406, IZ55574, IZ55587, IZ55628, IZ56672, IZ60555, IZ61689, IZ61960, IZ62250, IZ63045, IZ63765, IZ64152, IZ65922, IZ65654, IZ60181, IZ09389, IZ34147, IZ36915, IZ39304, IZ39828, IZ39917, IZ40064, IZ40796, IZ41051, IZ41214, IZ41892, IZ42192, IZ42332, IZ42347, IZ42604, IZ42619, IZ43671, IZ44203, IZ44277, IZ44747, IZ44824, IZ44924, IZ45266, IZ45326, IZ45327, IZ46821, IZ40046, IZ58193, IZ68880, IZ68877, IZ69530, IZ69749, IZ69206, IZ72170, IZ73267, IZ82438, IZ67528, IZ74221, IZ74228, IZ74277, IZ74697, IZ74503, IZ73165, IZ82445, IZ74732, IZ74946, IZ74882, IZ74914, IZ82448, IZ75610, IZ68758, IZ75836, IZ82449, IZ75910, IZ74503, IZ75487, IZ76402, IZ82450, IZ76061, IZ76442, IZ82451, IZ73532, IZ75519, IZ77986, IZ78102, IZ77246, IZ78374, IZ95300